DOWNLOAD LG F1021ND / F1021ND5 Service Manual ↓ Size: 2.14 MB | Pages: 37 in PDF or view online for FREE

Model
F1021ND F1021ND5
Pages
37
Size
2.14 MB
Type
PDF
Document
Service Manual
Brand
Device
Washing Machine
File
f1021nd-f1021nd5.pdf
Date

LG F1021ND / F1021ND5 Service Manual ▷ View online

29
1
Take apart the cabinet gasket clamp.
2
Unscrew 2 screws from the cabinet cover.
4
Take apart the lower cover.
3
Open the lower cover cap and unscrew 1 screw
inside.
1
Disassemble the control panel. (page 18)
2
Unscrew all the screws on the upper and lower
sides of the cabinet cover.
1
Take apart the tub gasket clamp.
2
Make sure that the drain hole of the gasket is put
beneath when reassembling the gasket.
efer to the arrow mark on the tub cover.
GASKET ASSEMBLY
Open the lower cover cap (     ) by
using a coin. Turn the drain plug 
(     ) to pull out the hose.
30
1
Remove the BACK COVER.
2
Unscrew the bolt to pull out the ROTOR assembly.
1
Disconnect the wiring connector.
2
Unscrew 6 bolts from the STATOR.
3
Remove the STATOR.
1
Pull out the hinge, pressing its snap.
1
2
2
Do not use the pulled-out hinge again. It may be
taken off during operation.
ROTOR ASSEMBLY, STATOR ASSEMBLY, FRICTION DAMPER ASSEMBLY
Clean the drain pump filter 
Unplug the drain plug (     ) , then
the water flows out, At this time
use a vessel to prevent water from
flowing on the floor. If the water
does not flow any more, turn the
pump filter (     ) open to the left.
2
3
Take out any foreign material from
the pump filter (     ). After
cleaning, turn the pump filter(     )
clockwise and insert the drain plug
(     ) to the original place. close
the lower cover cap.
3
3
2
Rotor
Bolt
(1)
Hinge,
Damper
Damper
(ROTOR ASSEMBLY)
(STATOR ASSEMBLY)
(DAMPER)
Note : Hook of connector (1) is on the backside
31
PUMP
1
Remove pump outlet hose.
2
Remove tub pump bellows.
3
Remove cap (Remaining Hose.)
4
Disconnect the wiring.
5
Unscrew 2 screws.
6
Remove the pump.
HEATER
1
Loosen the M6 heater nut to pull out the heater.
CAUTION
When mounting the heater, be sure to insert
the heater into the heater clip on the bottom
of the tub.
THERMISTOR 
1
Pull it out by holding the thermistor bracket.
2
When mounting the thermistor again, make sure
that it is got back tight to the bushing.
Tub Pump 
Bellows
Pump Outlet Hose
If it is pulled by the wire, it may be broken.
32
SWITCH ASSEMBLY, DOOR LOCK
1
Take apart the cabinet cover clamp and release
the gasket.
2
Unscrew 2 screws holding the door lock.
3
Disconnect the door lock from the wiring connector.
WHEN FOREIGN MATERIAL IS STUCK BETWEEN DRUM AND TUB
1
Remove the heater.
2
Remove the foreign material (wire, coin and others)
by inserting a long bar through the hole.
Page of 37
Display

Click on the first or last page to see other F1021ND / F1021ND5 service manuals if exist.