18
7-4. ERROR DISPLAY
If you press the [Start/Pause] button when an error in displayed, any error except software ERROR will
disappear and the machine will change into pause status.
In case of , , , if the error is not resolved within 15 sec. In case of other errors, if the
error is not resolved within 4 min. Power will be turned off automatically and the error only will be
blinked. But in the case of , power will not be turned off.
disappear and the machine will change into pause status.
In case of , , , if the error is not resolved within 15 sec. In case of other errors, if the
error is not resolved within 4 min. Power will be turned off automatically and the error only will be
blinked. But in the case of , power will not be turned off.
ERROR
SYMPTOM
CAUSE
WATER
I
NLET
E
RROR
Water has not reached to the pre-set level within 4 min.
since inlet valve operated, or water has not reached to
the normal level within 25 min.
Page 19
1
U
NBALANCED
E
RROR
2
WATER
O
UTLET
E
RROR
3
OVER
F
LOW
E
RROR
4
The appliance is tilted.
Laundry is gathered to one side.
Non distributable things are put into the drum.
Laundry is gathered to one side.
Non distributable things are put into the drum.
Page 20
Water has not drained enough within 8 min.
Page 21
Water is automatically being pumped out because too
amuch water is in the tub.
Page 23
P
RESSURE SENSOR
S/W
E
RROR
5
The sensor pressure switch is out of order.
Page 24
D
OOR OPEN
E
RROR
6
The [Start/Pause] button is pressed with the door open.
The door switch is out of order.
The door switch is out of order.
Page 25
T
HERMISTOR(HEATING)
E
RROR
7
The thermistor is out of order.
Page 26
C
URRENT
E
RROR
8
PWB ASSEMBLY (Main) is out of order
Replace the PWB assembly (Main)
Winding in the MOTOR is short-circuited.
Replace the MOTOR
MOTOR
L
OCKED
E
RROR
9
The Connector (3-pin, male, white) in the wire harness
is not connected to the Connector (3-pin, female, white)
of MOTOR.
Reconnect or repair the connector
The electric contact between the connectors [3-pin,
male, white in the wire harness and 6-pin, female, white
in the PWB ASSEMBLY (Main]) is bad or unstable.
Reconnect or repair the contact in the connector
The wire harness between the MOTOR and PWB
ASSEMBLY (Main) is cut (open circuited).
The hall sensor is out of order/defective.
Page 27
7-5. TROUBLESHOOTING WITH ERROR
Water Inlet Error (IE)
Is the water tap closed ?
[Note] Environmental safety check list
1. No water tap leakage & freeze.
2. No entanglement of water supply hose.
5. No the inlet filter clogged.
Check the
Water tap
and open it fully .
When there is water in the tub,
is the water level frequency
over 25.5KHz ?
is the water level frequency
over 25.5KHz ?
Reconnect or repair the
Connector
.
Or replace the
Harness
.
Replace the
Inlet Valve
.
Is the
Connector
connected correctly to
the
Main PCB
and the
Inlet Valve
?
Or is the
Harness
alright ?
Check the
Air Chamber
and
the Tube
(clogged)
And When you check the water level frequency again,
if it is over 25.5KHz, you replace
if it is over 25.5KHz, you replace
the Pressure switch.
YES
YES
NO
NO
Replace the
Main PCB
.
NO
YES
YES
NO
NO
Is the each resistance of Inlet Valve within
3.5 ~4.5 kΩ ?
3.5 ~4.5 kΩ ?
When the washing machine is started,
is operated the inlet valve?
is operated the inlet valve?
Pre. Valve
Main Valve
19
1
2
1
2
3. No water shortage. 4. No water supply hose leakage
Unbalanced Error (UE)
2
0
Does the load lean toward one
side, or is the load a few items?
Is the washing machine installed
at an angle?
Adjust the height of washing
machine to be kept horizontally.
( Page 7)
Is the laundry mixed?
The few items of clothing will clump together
and their weight will be in one place on the drum,
throwing the weight off during spin mode.
So add some laundry to overcome UE error.
And rearrange load to allow proper spinning.
Try rearranging the laundry in drum
Or the laundry is separated by size, type, and color.
Separate by size,
type and color
YES
YES
NO
NO
YES
2
1
Water Outlet Error (OE)
Is the drain hose kinked ?
Check drain hose for kink and straighten the
Hose
.
Drain Hose
Is the
Pump filter
clogged ?
Next Page
Check & Clean
Pump Filter
.
YES
YES
NO
NO
This kind of accumulation on the drain filter not only
prevents proper drainage, but also will promote
bacteria growth and cause odors.
This drain filter should be cleaned once a month.
prevents proper drainage, but also will promote
bacteria growth and cause odors.
This drain filter should be cleaned once a month.
* How to disassemble and clean pump filter
Open the Cover by coin or
finger(only new model)
Cover
Drain water by removing the
hose cap.
Disassemble the pump
filter by turning the filter
cap counterclockwise.
Filter clogged by foreign objects
Assemble & close cap
Pump Filter
filter Cap
Hose Cap
Clean the filter
Filter Cap