DOWNLOAD LG V-C3B52SD Service Manual ↓ Size: 775.91 KB | Pages: 15 in PDF or view online for FREE

Model
V-C3B52SD
Pages
15
Size
775.91 KB
Type
PDF
Document
Service Manual
Brand
Device
Vacuum Cleaner
File
v-c3b52sd.zip
Date

LG V-C3B52SD Service Manual ▷ View online

3828Fi5875A
-5-
DISASSEMBLY INSTRUCTIONS
NOTE: Before attempting to service or adjust any part of the vacuum cleaner, disconnect the electrical power supply cord
from the wall outlet.
Filter Cover
Cover Latch
Control Cover
Knob
Supporter
PWB
Assembly
Control Cover
Switch Knob
Exhaust 
Filter Cover
Exhaust Filter
• Almost all of the parts of this vacuum cleaner can be 
disassembled with a screw driver and each connecting
component easily fits each other. 
Disassemble one by one referring to the exploded view.
• If possible, don't disassemble except for the necessary
parts. It is not necessary to disassemble the  parts that
are not detailed in the exploded view.
1. Detach Body Cover Assembly from Body
Base Assembly
1) Open filter cover by pushing cover latch.
2) Remove exhaust filter cover & exhaust filter.
Then remove four screws.
2. P.W.B Assembly Replacement
1) Remove control cover using the flat driver, push it in the
direction of arrow.
2) Detach P.W.B assembly after removing control cover
and knob.
3828Fi5875A
Lever
Switch Knob
Filter Cover
Handle Assembly
-6-
3) When you re-assembling the P.W.B assembly, assemble
after sliding the lever of P.W.B assembly and switch
knob to the left.
3. Filter Cover Assembly
1) Remove handle assembly by pushing handle in the
direction of arrow.
2) Remove filter cover by pushing it in the direction of
arrow.
4. Motor Assembly Replacement.
• Lift the motor assembly in the direction of the arrow
after stripping off the lead wires.
5. Cord Reel Assembly Replacement
• Lift the cord reel assembly from the body base in the
direction of the arrow.
3828Fi5875A
-7-
SOLUTION
CAUSE
Check the power source
CHECKING
Poor plug insertion
Power cord cut
Interior lead wire cut
Motor(stator armature) coil cut 
or damaged
Poor contact carbon brush 
defaced
Motor armature cut
Ball bearing defacement
Impeller hindrance
(Caused by foreign matters)
Insert again
The fuse is melt down
in the coverknife switch
Exchange the fuse
Repair or exchange
Exchange the lead wire
Exchange the motor
Exchange or repair
Poor switch contact point
Exchange the switch
Exchange the motor
Exchange the motor
Remove the foreign matters
Normal
Abnormal
TROUBLE SHOOTING GUIDE
1. SWITCH ON BUT MOTOR DOSE NOT RUN.
2. SWITCH ON, MOTOR DOES NOT RUN BUT BUZZES.
Poor connection
Poor switch
Carbon brush defaced
Motor armature cut
Foreign matters attached to 
the impeller
Low voltage
Hose and extension wands are 
clogged with foreign matters
Filter bag or cloth bag is filled 
with inhaled foreign matters
Repair
Exchange the switch
Exchange the carbon brush 
or the motor
Exchange the motor
Remove the foreign matters
Inquire to the power utility 
company
Remove the foreign matters 
in the hose or extension wands
Low rotation speed
Motor turns normally, 
but suction power is weak 
Rotating switch is on low
mode
Rotate it with clock-wise so 
power is increasd
Remove the foreign matters 
or exchange the filter bag or 
clean the cloth bag
3. SWITCH OFF BUT MOTOR RUNS.
4. WEAK SUCTION POWER
-8-
3828Fi5875A
Page of 15
Display