LG Z42PQ20-UC (CHASSIS:PU92B) Service Manual ▷ View online

- 5 -
SPECIFICATIONS
V
General Specification
No.
1
2
3
4
5
6
7
8
9
10
Item
Receiving System
Available Channel
Input Voltage
Market
Screen Size
Aspect Ratio
Tuning System
Module
Operating Environment
Storage Environment
Specification
ATSC/64 & 256 QAM/NTSC-M
1) VHF : 02 ~ 13
2) UHF : 14 ~ 69
3) DTV : 02 ~ 69
4) CATV : 01 ~ 135
5) CADTV : 01 ~ 135
1) AC 100 ~ 240V  50/60Hz
2) AC 100 ~ 120V  50/60Hz
NORTH AMERICA
42 inch Wide(1024 X 768)
50  inch Wide(1365 X 768)
60  inch Wide(1365 X 768)
50  inch Wide(1920 X 1080)
60 inch Wide(1920 X 1080)
16 : 9
FS
PDP32F2####(852 X 480)
PDP42G2####(1024 X 768)
PDP50G2####(1365 X 768)
PDP50H3####(1920 X 1080)
PDP60H3####(1920 X 1080)
1) Temp : 0 ~ 40deg
2) Humidity : ~80%
1) Temp : -20 ~ 60deg
2) Humidity : 0 ~ 90%
- 6 -
ADJUSTMENT INSTRUCTIONS
1. Application Range
This spec sheet is applied to all of the “PU92B” Chassis.
2. Specification
(1) Because this is not a hot chassis, it is not necessary to use
an  isolation  transformer.  However,  the  use  of  isolation
transformer will help protect test instrument.
(2) Adjustment must be done in the correct order.
(3) The adjustment must be performed in the circumstance of
25±5
c
C  of  temperature  and  65±10%  of  relative  humidity  if
there is no specific designation.
(4)  The  input  voltage  of  the  receiver  must  keep  100~240V,
50/60Hz.
(5) The receiver must be operated for about 5 minutes prior to
the adjustment when module is in the circumstance of over
15cC
- In case of keeping module is in the circumstance of 0cC,
it should be placed in the circumstance of above 15cC for
2 hours 
- In case of keeping module is in the circumstance of below
-20cC,  it  should  be  placed  in  the  circumstance  of  above
15cC for 3 hours.
1) Press the POWER ON KEY on R/C for adjustment.
2) Press the ADJ KEY on R/C and enter EZ ADJUST.
Select  “4.  WHITE  PATTERN”  by  using 
D
/
E
(CH  +/-)  and
select “White” by using 
F
/
G
(VOL +/-)
-  Set  is  activated  HEAT  run  without  signal  generator  in  this
mode.
- Single color pattern (RED / BLUE / GREEN) of HEAT RUN
MODE uses to check panel.
Caution:  If  you  turn  on  a  still  screen  more  than  20  minutes
(Especially digital pattern, cross hatch pattern), an after
image  may  be  occur  in  the  black  level  part  of  the
screen.
Caution: Set up “RF mode(noise)” after PCB assembly adjustment.
3. Download
(1)  Execute  ISP  program  “Mstar  ISP  Utility”  and  then  click
“Config” tab.
(2) Set as below, and then click “Auto Detect” and check “OK”
message  If  display  “Error”,  Check  connect  computer,  jig,
and set.
(3)  Click  “Connect”  tab.  If  display  “Can’t”  ,  Check  connect
computer, jig, and set.
(4)  Click  “Read”  tab,  and  then  load  download  file(XXXX.bin)
by clicking “Read”
(5) Click “Auto” tab and set as below
(6) Click “Run”.
(7) After downloading, check “OK” message.
- 7 -
4. ADC Process
4-1. PC Input ADC
(1) Auto RGB Gain/Offset Adjustment
1) Convert to PC in Input-source
I2C  COMMAND:  0xF4  (SELECT_INPUT)  0x00  0x60
(RGB)
cf.  0x10(TV),  0x20(AV),  0x40(COMPONENT),  0x60
(RGB), 0x90(HDMI)
2) Signal equipment displays
3)  Adjust  by  commanding  AUTO_COLOR_ADJUST(0xF1)
0x00 0x02 instruction.
(2) Confirmation
1) We confirm whether “0xB6(RGB)” address of EEPROM
“0xA2” is “0xAA” or not. 
2) If “0xB6(RGB)” address of EEPROM “0xB2” isn’t “0xAA”,
we adjust once more
3)  We  can  confirm  the  ADC  values  from  “0xB0~0xB5
(RGB)” addresses in a page “0xA2”
[ Manual  ADC  process  using  Service  Remocon.  After  enter
Service Mode by pushing “ADJ” key, execute “ADC Adjust” by
pushing “
G
” key at “0. ADC CALIBRATION “. 
4-2. COMPONENT Input ADC
(1) Component Gain/Offset Adjustment
1) Convert to Component in Input-source
I2C  COMMAND  :  0xF4  (SELECT_INPUT)    0x00    0x40
(COMPONENT)
cf.  0x10(TV),  0x20(AV),  0x40(COMPONENT),  0x60
(RGB), 0x90(HDMI)
2) Signal equipment displays
3)  Adjust  by  commanding  AUTO_COLOR_ADJUST(0xF1)
0x00 0x02 instruction
4) Signal equipment displays
5)  Adjust  by  commanding  AUTO_COLOR_ADJUST(0xF1)
0x00 0x02 instruction
[ Manual  ADC  process  using  Service  Remocon.  After  enter
Service Mode by pushing “ADJ” key, execute “ADC Adjust” by
pushing “
G
” key at “0. ADC CALIBRATION”. 
4-3. Confirmation
(1)  We  confirm  whether  “0xBF(480i)/0xC8(1080i)”  address  of
EEPROM “0xA2” is “0xAA” or not. 
(2)  If  “0xBF(480i)/0xC8(1080i)”  address  of  EEPROM  “0xA2”
isn’t “0xAA”, we adjust once more
(3) We can confirm the ADC values from “0xB9 ~ 0xBE(480i) /
0xC2 ~ (1080i)” addresses in a page “0xA2”
[ Manual ADC Confirmation using Service Remocon. After enter
Service Mode by pushing “INSTART” key.
5. DDC EDID Write Confirmation
ADJUSTMENT INSTRUCTIONS
- 8 -
Caution: Each PCB assembly must be checked by check JIG set.
(Because  power  PCB  Assembly  damages  to  PDP
Module, especially be careful)
Caution: Set up “RF mode(noise)” before voltage adjustment.
6. POWER PCB Ass’y Voltage 
Adjustment
(Va, Vs voltage Adjustment)
6-1. Test Equipment:
D.M.M 1EA
6-2. Connection Diagram for Measuring
Refer to Fig.1, Fig 2, Fig 3
6-3. Adjustment Method 
(1) 50” Va Adjustment (refer fig.1)
1) After receiving 100% Full White Pattern, HEAT RUN.
2)  Connect  +  terminal  of  D.M.M.  to  Va  pin  of  P802,
connect-terminal to GND pin of P802.
3)  After  turning  VR902,voltage  of  D.M.M  adjustment  as
same  as  Va  voltage  which  on  label  of  panel  right/top
(deviation; ±0.5V)
(2) 50” Vs Adjustment (refer fig.1)
1) Connect + terminal of D.M.M. to Vs pin of P802, connect
-terminal to GND pin of P802.
2)  After  turning  VR901,  voltage  of  D.M.M  adjustment  as
same as Vs voltage which on label of panel right/top
(deviation ; ±0.5V)
(3) 42” Va Adjustment (refer fig.2)    
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D.M.M. to Va pin of P811, connect
-terminal to GND pin of P811.
3)  After  turning  VR901,voltage  of  D.M.M  adjustment  as
same  as  Va  voltage  which  on  label  of  panel  right/top
(deviation; ±0.5V)
(4) 42” Vs Adjustment (refer fig.2)
1)  Connect  +  terminal  of  D.  M..M.  to  Vs  pin  of  P811,
connect -terminal to GND pin of P811.
2)  After  turning  VR951,  voltage  of  D.M.M  adjustment  as
same as Vs voltage which on label of panel right/top
(deviation ; ±0.5V)
(5) 60” Va Adjustment (refer fig.3)    
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D.M.M. to Va pin of P11, connect
-terminal to GND pin of P11.
3)  After  turning  VR901,voltage  of  D.M.M  adjustment  as
same  as  Va  voltage  which  on  label  of  panel  right/top
(deviation; ±0.5V)
(6) 60” Vs Adjustment (refer fig.3)
1) Connect + terminal of D. M..M. to Vs pin of P11, connect
-terminal to GND pin of P11.
2)  After  turning  VR951,  voltage  of  D.M.M  adjustment  as
same as Vs voltage which on label of panel right/top
(deviation ; ±0.5V)
ADJUSTMENT INSTRUCTIONS
(Fig. 1) 50inch Power PCB Assy Voltage Adjustment
(Fig. 2) 42inch Power PCB Assy Voltage Adjustment
(Fig. 3) 60inch Power PCB Assy Voltage Adjustment