- 16 -
(3) UDTV(84LM9600-SA)_Nomalline
H/R Time(Min)
Cool
Medium
Warm
x
y
x
x
y
x
269
273
285
293
313
329
1
0-2
280
287
296
307
320
337
2
3-5
279
285
295
305
319
335
3
6-9
277
284
293
304
317
334
4
10-19
276
283
292
303
316
333
5
20-35
274
280
290
300
314
330
6
36-49
272
277
288
297
312
327
7
50-79
271
275
287
295
311
325
8
80-119
270
274
286
294
310
324
9
Over 120
269
273
285
293
309
323
(4) UDTV(84LM9600-SA)_ aging chamber
H/R Time(Min)
Cool
Medium
Warm
x
y
x
x
y
x
269
273
285
293
313
329
1
0-5
280
287
296
307
320
337
2
6-10
277
284
293
304
317
334
3
11-20
276 
282 
292 
302 
316 
332 
4
21-30
274 
280 
290 
300 
314 
330 
5
31-40
272 
276 
288 
296 
312 
326 
6
41-50
270 
272 
286 
292 
310 
322 
7
51-80
266 
269 
282 
289 
306 
319 
8
81-119
264 
267 
280 
287 
304 
317 
9
Over 120
263 
266 
279 
286 
303 
316 
■  In the SET applied LED module (LM9600), cause of the physical 
characteristics of LED Module, sets are taken a 120 minutes by 
aging time to stabilize a color coordinates. 
    So White Balance Control equipments have to get the SET Aging 
Time from the SET and then going to control the W/B by revise 
color coordinates at each time
-  To check the Coordinates of White Balance, you have to measure 
at the below conditions.
  Picture Mode : select Vivid and change  
                          Dynamic Contrast : Off , 
                          Dynamic Colour : Off, 
                          Clear White : Off
            => Picture Mode change : Vidid => Vivid(User)
(If  you  miss  the  upper  condition,  the  coordinates  of  W/B  can  be 
lower than the spec.)
  Connecting picture of the measuring instrument 
         (On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to 
auto controller or push Adjustment R/C POWER-ON -> Enter 
the mode of White-Balance, the pattern will come out.
 Auto-control interface and directions
(1)  Adjust  in  the  place  where  the  influx  of  light  like  floodlight 
around is blocked. (Illumination is less than 10ux).
(2)  Adhere closely  the Color Analyzer ( CA210 ) to the module 
less  than  10cm  distance,  keep  it  with  the  surface  of  the 
Module and Color Analyzer’s Prove vertically.(80~100°).
(3) Aging time
-  After  aging  start,  keep  the  power  on  (no  suspension  of 
power supply) and heat-run over 5 minutes.
-  Using ‘no signal’ or ‘full white pattern’ or the others, check 
the back light on.
● Auto adjustment Map(RS-232C)
   RS-232C COMMAND
   [ CMD    ID    DATA ]    
       Wb     00       00       White Balance Start
       Wb     00       ff        White Balance End  
RS-232C COMMAND
[CMD ID DATA]
MIN
CENTER
(DEFAULT)
MAX
Cool
Mid
Warm
Cool
Mid
Warm
R Gain
jg
Ja
jd
00
172
192
192
192
G Gain
jh
Jb
je
00
172
192
192
192
B Gain
ji
Jc
jf
00
192
192
172
192
R Cut
64
64
64
128
G Cut
64
64
64
128
B Cut
64
64
64
128
- 17 -
** Caution **
Color Temperature : COOL, Medium, Warm.
One  of  R  Gain/G  Gain/  B  Gain  should  be  kept  on  0xC0,  and 
adjust other two lower than C0.
(when R/G/B Gain are all C0, it is the FULL Dynamic Range of  
Module)
*Manual W/B process using adjusts Remote control.
■After enter Service Mode by pushing “ADJ” key,
■Enter White Balance by pushing “►” key at “7. White Balance”.
  After  You  finish  all  adjustments,  Press  “In-start”  button  and 
compare Tool option and Area option value with its BOM, if it is 
correctly same then unplug the AC cable.
     If it is not same, then correct it same with BOM and unplug AC 
cable.  For  correct  it  to  the  model’s  module  from  factory  JIG 
model.
  Push  The  “IN  STOP  KEY”  after  completing  the  function 
inspection. And Mechanical Power Switch must be set “ON”. 
4.2. DDC EDID Write (RGB 128Byte)
■ Connect D-sub Signal Cable to D-Sub Jack.
■  Write  EDID  DATA  to  EEPROM  (24C02)  by  using  DDC2B 
protocol.
■ Check whether written EDID data is correct or not.
*  For SVC main Ass’y, EDID have to be downloaded to Insert 
Process in advance.
4.3. DDC EDID Write (HDMI 256Byte)
■ Connect HDMI Signal Cable to HDMI Jack.
■  Write  EDID  DATA  to  EEPROM(24C02)  by  using  DDC2B 
protocol.
■ Check whether written EDID data is correct or not.
*  For SVC main Ass’y, EDID have to be downloaded to Insert 
Process in advance.
4.4. EDID DATA
1) All Data : HEXA Value
2) Changeable Data :
    *: Serial No : Controlled / Data:01
    **: Month : Controlled / Data:00
    ***:Year : Controlled
    ****:Check sum
- Auto Download
■ After enter Service Mode by pushing “ADJ” key,
■ Enter EDID D/L mode.
■ Enter “START” by pushing “OK” key. 
 Edid data and Model option download (RS232C)
NO
Item
CMD 1 CMD 2
Data 0
Enter  
download 
MODE
Download
 ‘Mode In’
A
A
0
0
When transfer 
the  ‘Mode In’,
Carry the com-
mand
Edid data 
and Model 
option
download
Download
A
E
00
10
Automatically 
download
(The use of a 
internal Data)
LM8600-SA   
HDMI  EDID Data(Model name = LG TV )
HDMI-1 EDID table (0x43, 0x11)
1) HDMI 1 Check sum : 0x43, 0X11  (CEA Block 0x1E :10)
2) HDMI 2 Check sum : 0x43, 0X01  (CEA Block 0x1E :20)
3) HDMI 3 Check sum : 0x43, 0XF1  (CEA Block 0x1E :30)
4) HDMI 4 Check sum : 0x43, 0XE1  (CEA Block 0x1E :40)
- 18 -
RGB EDID DATA RGB CheckSum : 5C
4.6. Local Dimming Inspection
(1)  Press  ‘TILT”  key  of  the  Adj.  R/C  and  check  moving 
patterns. The black bar patterns moves from top to bottom.
      If a local dimming function does not work, a whole screen 
shows full white.
4.7. EYE-Q Check  
Step 1) Turn on the TV..
Step 2)  Press  'EYE  button'  on  the  adjustment  remote-
controller.
Step 3)  Cover  'Eye  Q  sensor'  on  the  front  of  set  with  your 
hands, hold it for 6 seconds.
Step 4)  Check "the Sensor Data" on the screen, make certain 
that  Data  is  below  10.  If  Data  isn’t  below  10  in  6 
seconds,  Eye  Q  sensor  would  be  bad.  You  should 
change Eye Q sensor.
Step 5)  Uncover your hands from Eye Q sensor, hold it for 6 
seconds.
Step 6)  Check  "Back  Light(xxx)"  on  the  screen,  check  data 
increase . You should change Eye Q sensor. 
4.8. Magic Motion remote controller Check
4.8.1 Test equipment
-  RF-remote  controller  for  check,  IR-KEY-CODE  remote 
controller.
-  Check AA  battery  before  test. A  recommendation  is  that  a 
tester change battery every lots.
4.8.2. Test
(1)  Make pairing with TV set by pressing “Mute (START) key” 
on RCU.
(2)  Check  a  cursor  on  screen  by  pressing  ‘ENTER”  or  “OK” 
key of RCU
(3) Stop paring with TV set by pressing “VOL+ (STOP) key.
4.9. 3D pattern test (Only for 3D models)  
4.9.1. Test equipment
(1)  Pattern  Generator  MSHG-600  or  MSPG-6100  (HDMI  1.4 
support)
(2) Pattern: HDMI mode (model No. 872, pattern No. 83)
4.9.2. Test method
(1) Input 3D test signal as Fig.1.
(2) Press ‘OK” key as a 3D input OSD is shown.
(3)  Check  pattern  as  Fig2  without  3D  glasses.  (3D  mode 
without 3D glasses)
            Fig.2   
 
 
 
                Fig.3
<OK in 3D mode without 3D glasses>         <NG in 3D mode without 3D glasses>
 
<Step 2>
<Step 5>
<Step 6>
<Step 3>
<Step 4>
- 19 -
4.10. HDMI ARC Function Inspection  
4.10.1. Test equipment
- Optic Receiver Speaker          
- MSHG-600 (SW: 1220 ↑) 
- HDMI Cable (for 1.4 version)
4.10.2. Test method
(1)  Insert  the  HDMI  Cable  to  the  HDMI ARC  port  from  the 
master equipment (HDMI1)
(2) Check the sound from the TV Set
(3)  Check  the  Sound  from  the  Speaker  or  using AV  &  Optic 
TEST program (It’s connected to MSHG-600)
* Remark:  Inspect in Power Only Mode and check SW version 
in a master equipment
4.11. Outgoing condition Configuration
■  When  pressing  IN-STOP  key  by  SVC  remocon,  Red  LED 
are blinked alternatively. And then automatically turn off.
   (Must not AC power OFF during blinking)
 
4.12. GND and Hi-Pot test
4.12.1. Test equipment
(1)  Check  the  POWER  CABLE  and  SIGNAL  CABE  insertion 
condition 
 
4.12.2. GND & HI-POT auto-check
(1)  Pallet moves in the station. (POWER CORD / AV CORD is 
tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) GND Test (Auto) 
    - If Test is failed, Buzzer operates.
    -  If  Test  is  passed,  execute  next  process  (Hi-pot  test). 
(Remove A/V CORD from A/V JACK BOX)
(5) HI-POT test (Auto)
    - If Test is failed, Buzzer operates.
    -  If  Test  is  passed,  GOOD  Lamp  on  and  move  to  next 
process automatically.
4.12.3. Checkpoint
(1) Test voltage
  ▪ 3 Poles 
    - GND: 1.5KV/min at 100mA
    - SIGNAL: 3KV/min at 100mA
(2) TEST time: 1 second
(3) TEST POINT
  ▪ 3 Poles
     -  GND Test  =  POWER  CORD  GND  and  SIGNAL  CABLE 
GND.
     -  Hi-pot  Test  =  POWER  CORD  GND  and  LIVE  & 
NEUTRAL.
(4) LEAKAGE CURRENT: At 0.5mArms