DOWNLOAD LG 72LEX9S-CA (CHASSIS:LC03N) Service Manual ↓ Size: 9.07 MB | Pages: 40 in PDF or view online for FREE

Model
72LEX9S-CA (CHASSIS:LC03N)
Pages
40
Size
9.07 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD
File
72lex9s-ca-chassis-lc03n.pdf
Date

LG 72LEX9S-CA (CHASSIS:LC03N) Service Manual ▷ View online

- 9 -
4.3.2 LAN inspection solution 
    - LAN Port connection with PCB 
- Network setting at MENU Mode of TV 
- Setting automatic IP 
- Setting state confirmation 
 If automatic setting is finished, 
  you confirm IP and MAC Address. 
4.4 LAN PORT INSPECTION(PING TEST) 
4.4.1. Equipment setting 
    1) Play the LAN Port Test PROGRAM. 
    2) Input IP set up for an inspection to Test   
            Program. 
       
*IP Number : 12.12.2.2 
4.4.2. LAN PORT inspection (PING TEST) 
    1) Play the LAN Port Test Program. 
    2) connect each other LAN Port Jack. 
    3) Play Test (F9) button and confirm OK Message. 
    4) remove LAN CABLE 
 
4.5 EDID download 
1)
 Enter ‘EZ ADJUST’ mode by pushing ‘ADJ’ key. 
2) Select and enter ’
10.EDID D/L’ mode. 
3) Select ‘
START’ by pushing ‘OK’ key. 
  Caution : Never connect HDMI & D-sub Cable 
when auto download. 
EDID D/L 
HDMI1 
NG 
 
HDMI2 
NG 
 
HDMI3 
NG 
 
RGB 
NG 
 
 
 
Start 
 
Reset 
 
 
EDID D/L 
HDMI1 
OK 
 
HDMI2 
OK 
 
HDMI3 
OK 
 
RGB 
OK 
 
 
Start 
Reset 
 
 
 
EDID data and Model option download (RS232) 
NO 
Item 
CMD
   1 
CMD
   2 
Data
    0 
Enter 
 download
 MODE 
Download 
  ‘Mode In’ 
0  0 
When transfer 
the ‘Mode In’, 
Carry the 
command. 
data and 
Model option 
Download 
Download  A 
00  10 
Automatically 
download 
(The use of a 
internal Data) 
EDID 
- 10 -
 
 Manual Download 
* Use the proper signal cable for EDID Download 
    - Analog EDID : Pin3 exists 
            - Digital EDID : Pin3 exists 
 Caution 
- Never connect HDMI & D-sub Cable at the 
  same time. 
- Use the proper cables as below for EDID writing. 
- Download HDMI1, HDMI2, HDMI3 separately 
  because each data is different. 
For Analog EDID
 
For HDMI EDID
 
D-sub to D-sub 
DVI-D to HDMI or HDMI to HDMI 
 
 
 
 
■ 72LEX9(s)-CA 
RGB
 EDID data : 128 byte ] 
 
  0  1  2  3  4  5  6  7  8  9  A  B  C  D  E  F 
00  00  FF  FF  FF  FF  FF FF 00
1E 6D
 
 
10 
 
01  03 
68 
10 09
78 0A
EE 91
A3
54 
4C 
99  26
20 
0F  50  54 
A1  08  00 81 80 61 40 45 40 31  40  01  01
30  01  01  01  01  01  01 02 3A 80 18 71 38 2D  40  58  2C
40  45  00 
A0  5A  00 
00 00 1E 01 1D 00 72 51  D0  1E  20
50  6E  28  55  00 
A0  5A 00
00 00 1E 00 00 00  FD  00  3A
60  3E  1E  53  10  00  0A 20 20 20 20 20 20
 
70 
 
00  ⓔ
HDMI
 EDID data : 256 byte ] 
 
  0 
00  00  FF  FF  FF  FF  FF FF 00
1E 6D
 
 
10 
 
01  03 
80 
10
09
78
0A
EE 91
A3
54 
4C 
99  26
20 
0F  50  54 
A1  08  00
71
4F
81
80
01
01
01  01  01  01
30  01  01  01  01  01  01
02
3A
80
18
71
38
2D  40  58  2C
40  45  00 
A0  5A  00 
00
00
1E
01
1D
00
72
51  D0  1E  20
50  6E  28  55  00 
A0  5A
00
00
00
1E
00
00
00  FD  00  3A
60  3E  1E  53  10  00  0A 20
20
20
20
20
20
 
70 
 
01  ⓔ
80  02  03  26  F1  4E  10
1F
84
13
05
14
03
02  12  20  21
90  22  15  01  26  15  07
50
09
57
07
 
A0 
 
E3  05  03  01
01
1D
80
18
71
1C
16  20  58  2C
B0  25  00 
A0  5A  00 
00
00
9E
01
1D
00
80
51  D0  0C  20
C0  40  80  35  00 
A0  5A
00
00
00
1E
02
3A
80  18  71  38
D0  2D  40  58  2C  45  00
A0 5A
00
00
00
1E
66  21  50  B0
E0  51  00  1B  30  40  70
36
00
A0 5A
00
00
00  1E  00  00
F0  00  00  00  00  00  00
00
00
00
00
00
00
00  00  00  ⓔ
No. 
Item 
Condition 
Hex Data 
1  Manufacturer ID 
GSM 
1E6D 
2  Version 
Digital : 1 
01 
3  Revision 
Digital : 3 
03 
 Detail EDID Options are below (ⓐ, ⓑ, ⓒ, ⓓ, ⓔ, ⓕ) 
 Product ID 
MODEL NAME  HEX  EDID Table  DDC Function 
FHD 
0001 
01
 00 
Analog/Digital 
 Serial No. : Controlled on production line. 
 Week, Year : Fixed as S/W 
released day(same as MES data) 
                              Week 0x02(2), Year 0x13(2009) 
 Model Name(Hex) : 
MODEL 
MODEL NAME(HEX) 
Remark 
All Models 
00 00 00 FC 00 4C 47 20 54 56 0A 
20 20 20 20 20 20 20
LG TV 
 Checksum 
Model  RGB 
HDMI1 
HDMI2 
HDMI3 
FHD 
0x1d  0xD7, 0x39  0xD7, 0x29  0Xd7, 0x19 
 Vendor Specific(HDMI) 
Model  INPUT  HEX 
Remark 
HDMI1  67 03 0C 00 
10
 00 B8 2D 
HDMI2  67 03 0C 00 
20
 00 B8 2D 
FHD 
67 03 0C 00 
30
 00 B8 2D 
HDMI3 
4.6 
V-Com
 adjustment(
Only M+S models
 which use LGD module) 
1) Why need Vcom adjustment? 
       
  ▣ The Vcom (Common Voltage) is a Reference 
 Liquid Crystal need for Polarity Change with 
 every frame.   
Voltage of Liquid Crystal Driving. 
Row Line
Column  Line
C
LC
C
ST
Panel
S
Y
S
T
E
M
G
at
e
 Driv
e
 IC
So urce D r iv e  I C
Circuit Block
Ti m in g  
Co nt r o ll er
Po w er  
Blo ck
V
COM
Gamma
Re f er ence V o ltage
Gamm a Reference
Volta ge
Data (R,G,B) & C ontro l s ignal
Control si gnal
Data (R,G,B ) &
Control si gnal
In
te
rf
a
ce
TFT
Po w er  I n p u t
Power Input
Da t a I n p u t
Da t a I n p u t
V
COM
Liquid 
Crystal
V
COM
2) Adjust sequence  (Method  1) 
- Push  ‘
PIP’  key  . 
If there  is flicker at default value, turn down or 
 
turn up  until  no flicker,  push  ‘OK’  key  to  store. 
- Push ‘
Exit’  key to  exit. 
- 11 -
3) Adjust sequence  (Method  2) 
- Enter ‘
EZ ADJUST’ mode by pushing ‘ADJ’ key. 
- Select and enter ’
12.V-Com’ mode. 
If there  is flicker at default value, turn down 
or turn up  until  no flicker,  push  ‘OK’  key  to  store. 
- Push ‘
Exit’  key to  exit. 
V-Com 
 
V-COM 
370 
 
Press () to save. 
 
4.6 Model name & Serial number Download 
4.61 Model name & Serial number D/L 
1) Press “Power on” key of service remocon.
    (Baud rate : 115200 bps)
 
2) Connect RS232 Signal Cable to RS-232 Jack. 
3) Write Serial number by RS-232. 
4) Check the serial number in ‘IN-START’ menu.   
4.6.2  Method & notice 
    1) Serial number D/L is using of scan equipment. 
2) Setting of scan equipment operated by Manufacturing 
    Technology Group. 
3) Serial number D/L must be conformed when it is 
 Manual Download (Model Name and Serial Number) 
If the TV set is downloaded by OTA or Service man, so
metimes model name or serial number is initialized. 
There is impossible to download by bar code scan, 
so It need Manual download. 
1) Press the ‘IN-START’ key of ADJ remote controller. 
2) Go to the menu ‘
5.Model Number D/L
’ like below photo. 
3) Input the Factory model name (ex 72LEX9-CA) or
4) Check the model name in ‘IN-START’ menu 
 Factory name displayed (ex 72LEX9-CA) 
produced in production line, 
 Serial number like photo. 
5. Manual Adjustment 
5.1 ADC(GP2 BCM) Adjustment 
5.1.1 Overview 
ADC adjustment is needed to find the optimum black level 
and gain in Analog-to-Digital device and to compensate 
RGB deviation. 
5.1.2 Equipment & Condition 
1) Adjust Remocon 
2) 801GF(802B, 802F, 802R) or MSPG925FA Pattern 
    Generator 
      - Resolution: 480i, 720*480
 MSPG-925FA 
 Model: 209, Pattern: 65) - 480i
 1080p, 1920*1080
 (MSPG-925FA 
 Model: 225, Pattern: 65) - 1080p   
   
  - Pattern : Horizontal 100% Color Bar Pattern 
   
  - Pattern level: 0.7±0.1 Vp-p 
      - Image 
 
3) Must use standard cable 
5.1.3 Adjust method 
5.1.3.1 ADC 480i, 1080p Comp1 
1) Check connected condition of Comp1 cable to 
    the equipment 
2) Give a 
480i1080p ModeHorizontal 100%
 Color Bar Pattern to Comp1. 
   
(MSPG-925FA   Model: 209, Pattern: 65) - 480i 
(MSPG-925FA   Model: 225, Pattern: 65) - 1080p 
3) Change input mode as Component1 and picture 
    mode as “Standard” 
4) Press the In-start Key on the ADJ remote after at least 1 
min of signal reception. Then, select 7. External ADC -> 
 
1. COMP 1080p on the menu. Press enter key.
 The adjustment will start automatically. 
5) If ADC calibration is successful, “ADC COMPONEN
T Success” is displayed. 
If ADC calibration is failure, “ADC COMPONENT Fail” 
is displayed. 
6) If ADC calibration is failure, after recheck ADC pattern 
Error message refer to 5) 
or condition retry calibration 
 model:255 , pattern:65 )
 
 
3) Change input mode as RGB and picture mode as 
     “Standard” 
4) Press the In-start Key on the ADJ remote after at 
    least1 min of signal reception. Then, select 7. 
  1. COMP 1080p on the menu. Press enter key.
 The adjustment will start automatically. 
5) If ADC calibration is successful, “ADC RGB Success” 
    is displayed. 
If ADC calibration is failure, “ADC RGB Fail” is 
displayed. 
6) If ADC calibration is failure, after recheck ADC 
Error message 
5.2 White Balance Adjustment 
5.2.1 Overview 
1) W/B adj. Objective & How-it-works 
- Objective: To reduce each Panel’s W/B deviation 
- How-it-works: When R/G/B gain in the OSD is at 
 its Full Dynamic Range. 
prevent saturation of Full Dynamic range and data, 
one of R/G/B is fixed at 192, and the other two is 
lowered to find the desired value.   
-Adj. condition : normal temperature 
 Surrounding Temperature: 25±5℃ 
 Warm-up time: About 5 Min 
 Surrounding Humidity: 20% ~ 80% 
5.2.2 Equipment 
1) Color Analyzer: CA-210 (
LED Module : CH 14
2) Adj. Computer(During auto adj., RS-232C protocol 
3) Adjust Remocon 
4) Video Signal Generator MSPG-925F 720p/216-
    Gray (Model:217, Pattern:78) 
       
→ Only when internal pattern is not available 
 Color Analyzer Matrix should be calibrated using 
 CS-1000
 
 Bar Pattern 
pattern or condition retry calibration 
refer to 5) 
192, it means the panel is at
In order to 
is needed) 
External ADC -> 
5.2.3 Equipment connection MAP 
Ex) 
wb 00 00      ->    Begin white balance auto-adj. 
            wb 00 10      ->    Gain adj. 
            ja 00 ff      ->    Adj. data 
            jb 00 c0 
            ... 
            ... 
wb 00 1f      -> Gain adj. complete 
*(wb 00 20(start), wb 00 2f(endc)) -> Off-set adj. 
wb 00 ff      ->End white balance auto adj. 
3) Adj. Map 
Adj. item 
Command 
(lower  
Data 
Range 
(Hex.) 
Default 
(Decimal) 
CMD1  CMD2  MIN  MAX
R Gain  j 
00  C0 
172 
G Gain  j 
00  C0 
172 
Gain  j 
00 
C0 
192 
Cut 
 
 
 
64 
Cool 
Cut 
 
 
 
64 
caseASCII)
- 12 -
5.1.3.2 ADC 1920*1080 RGB 
1) Check connected condition of Component & RGB 
    cable to the equipment 
2) Give a 
1920*1080 Mode, 100% Horizontal Color 
to RGB port. 
     
(MSPG-925 Series 
Color Analyzer 
Computer 
Pattern Generator 
※If TV internal pattern is used, not 
Signal 
Source 
Probe 
RS-
232C 
RS-
232C 
RS-
232C 
5.2.4 Adj. Command (Protocol) 
1) Command Format 
START    6E    A    50    A    LEN    A    03    A    CMD   
A    00    A    VAL    A    CS    A STOP 
- LEN: Number of Data Byte to be sent 
  - CMD: Command 
  - VAL: FOS Data value 
  - CS: Checksum of sent data 
  - A: Acknowledge 
      Ex) [Send: JA_00_DD] / [Ack: A_00_okDDX] 
2) RS-232C Command used during auto-adj.
 
RS-232C 
COMMAND 
[CMD
      ID
            DATA] 
Explanation 
wb 
00  00 
Begin White Balance adj. 
wb 
00  10 
Gain adj.(internal white pattern) 
wb 
00  1f 
Gain adj. completed 
wb 
00  20 
Offset adj.(internal white pattern) 
wb 
00  2f 
Offset adj. completed 
wb 
00  ff 
End White Balance adj. 
(internal pattern disappears ) 
 
Details 
 
 
 
 
 
 
Page of 40
Display