DOWNLOAD LG 60PZ850T-ZA (CHASSIS:PD11B) Service Manual ↓ Size: 9.14 MB | Pages: 73 in PDF or view online for FREE

Model
60PZ850T-ZA (CHASSIS:PD11B)
Pages
73
Size
9.14 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / Plasma
File
60pz850t-za-chassis-pd11b.pdf
Date

LG 60PZ850T-ZA (CHASSIS:PD11B) Service Manual ▷ View online

- 9 -
* After You finish all adjustments, Press °
∞In-start°± button
and compare Tool option and Area option value with its
BOM, if it is correctly same then unplug the AC cable.
If it is not same, then correct it same with BOM and unplug
AC cable.
For correct it to the model’s module from factory JIG model.
* Push The “N STOP KEY” after completing the function
inspection. And Mechanical Power Switch must be set “ON”. 
* To check the coordinates of White Balance, you have to
measure at the below conditions.
Picture mode : Vivid, Energy Saving : Off, Below the
Advanced control, Dynamic Contrast : Off, Dynamic Colour :
Off 
Colour Temp. 
-> Picture Mode change : Vivid ? Vivid(User)
7-3. DPM operation confirmation 
(Only Apply for MNT Model)
* Check if Power LED Color and Power Consumption operate
as standard. 
(1) Set Input to RGB and connect D-sub cable to set
(2) Measurement Condition: (100~240V@ 50/60Hz)
(3) Confirm DPM operation at the state of screen without
Signal
7-4. DDC EDID Write (RGB 128Byte )
-> Not used any more, Use Auto D/L
(1) Connect D-sub Signal Cable to D-Sub Jack.
(2) Write EDID DATA to EEPROM (24C02) by using DDC2B
protocol.
(3) Check whether written EDID data is correct or not.
* For SVC main Ass’y, EDID have to be downloaded to
Insert Process in advance.
7-5 DDC EDID Write (HDMI 256Byte) 
-> Not used any more, Use Auto D/L
(1) Connect HDMI Signal Cable to HDMI Jack.
(2) Write EDID DATA to EEPROM(24C02) by using DDC2B
protocol.
(3) Check whether written EDID data is correct or not.
* For SVC main Ass’y, EDID have to be downloaded to
Insert Process in advance.
7-6. EDID DATA
(1) All Data : HEXA Value
(2) Changeable Data :
*: Serial No : Controlled / Data:01
**: Month : Controlled / Data:00
***:Year : Controlled
****:Check sum
7-7. EDID DATA Auto Download
(1) Press Adj. key on the Adj. R/C,
(2) Select EDID D/L menu.
(3) By pressing Enter key, EDID download will begin
(4) If Download is successful, OK is display, but If Download is
failure, NG is displayed.
(5) If Download is failure, Re-try downloads.
*Caution: Never connect HDMI & D-sub Cable when EDID
downloaded.
Edid data and Model option download (RS232)
7-8. Manual Download
* Caution
* Use the proper signal cable for EDID Download
- Analog EDID : Pin3 exists
- Digital EDID : Pin3 exists
* Caution: 
- Never connect HDMI & D-sub Cable at the same time.
- Use the proper cables below for EDID Writing.
- Download HDMI1, HDMI2 separately because HDMI1 is
different from HDMI2.
NO
Item
CMD 1 CMD 2 Data 0
Enter  
download     A
A
0     0 When transfer the
download 
‘Mode In’
‘Mode In’
Mode
Carry the 
command.
EDID data download
E
00  10 Automatically
Model
download
option
(The use of 
download
a internal pattern)
No.
Item
Condition
Hex Data
1
Manufacturer ID
GSM
1E6D
2
Version
Digital : 1
01
3
Revision
Digital : 3
03
- 10 -
7-9. EDID DATA
(1) 3D - FHD RGB EDID data
(2) 3D - FHD HDMI1 EDID data
(3) 3D - FHD HDMI2 EDID data
(4) 3D - FHD HDMI3 EDID data
ⓐ Vender ID
Checksum: Changeable by total EDID data.
8. Checking the EYE-Q Operation.
(1) Press the EYE Key on the adjustment remote controller.
(2) Check the Sensor DATA ( It must be under 10) and keep
the data longer than 1.5s
(3) Check ‘OK’
(Sensor DATA 0 ~ 4095, Power Saving Mode 0 ~ 12)
* IF you press IN-STAP Button, change Green Eye-check OSD.
- 11 -
9. 3D Function Test
(Pattern Generator MSPG-3233, HDMI mode NO. 371 ,
pattern No. 81)
(1) Please input 3D test pattern like below
(2) Enter 3D mode , then select side by side
(If you don’t wear a 3D Glasses, you will see the picture
like below)
(3) Put on the 3D Glasses, And block the right side of Glasses 
(LEFT:OPEN[TEST], RIGHT:CLOSED)
And check the middle sides of picture , RED -> normal ,
others -> abnormal
(4) Put on the 3D Glasses, And block the right side of Glasses 
(LEFT:CLOSED, RIGHT:OPEN[TEST])
And check the middle sides of picture , BLUE -> normal ,
others -> abnormal
10. Model name & Serial number
download
10-1. Model name & Serial number D/L 
(1) Press “Power on” key of service remocon.(Baud rate :
115200 bps)
(2) Connect RS232 Signal Cable to RS-232 Jack.
(3) Write Serial number by use RS-232.
(4) Must check the serial number at signal test of customer
support. (Refer to below).
10-2. Signal TABLE
CMD
: A0h 
LENGTH : 85~94h (1~16 bytes)
ADH
: EEPROM Sub Address high (00~1F)
ADL
: EEPROM Sub Address low (00~FF)
Data
: Write data
CS
: CMD + LENGTH + ADH + ADL + Data_1 + ... + 
Data_n
Delay
: 20ms
10-3. Command Set
[Description]
FOS Default write : <7mode data> write
Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart,
0, Phase
Data write : Model Name and Serial Number write in
EEPROM,.
10-4. Method & notice
(1) Serial number D/L is using of scan equipment.
(2) Setting of scan equipment operated by Manufacturing
Technology Group.
(3) Serial number D/L must be conformed when it is produced
in production line, because serial number D/L is mandatory
by D-book 4.0
* Manual Download (Model Name and Serial Number)
- If the TV set is downloaded By OTA or Service man,
Sometimes model name or serial number is initialized.(
Not always)
- There is impossible to download by bar code scan, so It
need Manual download.
- 12 -
1) Press the ‘instart’ key of ADJ remote controller.
2) Go to the menu ‘5.Model Number D/L’ like below photo.
3) Input the Factory model name(ex 42LD450-TA) or Serial
number like photo.
4) Check the model name Instart menu ? Factory name
displayed.
5) Check the Diagnostics (DTV country only) ? Buyer
model displayed.
11. Download MAC Address, 
CI+ Key and widevine Key.
<Check whether the key was downloaded or not at “In Start”
menu. (Refer to below).>
-> MAC Address need only DVB-T2 Model (ex.50PZ550T-ZA). 
* Connect TV SET and PC which download keys Writing
program by RS232C-Cable
(1) Start “MAC+CIKeyl.exe” Program and Click (3) Button to
connect TV and PC.
(2) Click (4) to download MAC Address.
(3) Click (5) to download CI+ Key.
(4) When download succeed, you can see “OK” on (6)
* Each Chassis has it’s own MAC Address. Please be careful
of download.
11-1. 
Check the method of RS232C
Command 
(1) into the main ass
’y mode (RS232 : aa 00 00)
(2) check the key download for transmitted command 
(RS232 : ci 00 10)
(3) result value
- normally status for download : OKx
- abnormally status for download : NGx
11-2. Check the method of CI+ Key value
(RS232)
(1) into the main ass
’y mode (RS232 : aa 00 00)
(2) Check the mothed of CI+ key by command 
(RS232 : ci 00 20)
(3) result value
12. Touch Pen Operating check
(Pen touch model only)
(1) Press Pen mode hot key to insert check mode in POWER
ONLY condition.
(Green Pen mode key on center of remocon)
(2) Pen check mode 
: You can see a 2X5 matrix. (Checker have to use right-hand.)
(3) 2X5 Matrix construction 
: When the screen is divided by fixel in 16:9, matrix is
applicable 14th,15th fixel in row, 3rd ~ 7th fixel in colume.
And they are numbered from 1 to 10. 
(TV & Jig Monitor is numbered samely.)
(4) When checker touched a box numbered 3 of Pen touch
TV, same box of JIG monitor blinks three times. 
CMD 1
CMD 2
Data 0
A
A
0         0
CMD 1
CMD 2
Data 0
C
1
1        0
CMD 1
CMD 2
Data 0
A
A
0         0
CMD 1
CMD 2
Data 0
C
1
2        0
Page of 73
Display

Click on the first or last page to see other 60PZ850T-ZA (CHASSIS:PD11B) service manuals if exist.