- 5 -
V
Module Specification
(1) 50” FHD
(2) 60” FHD
Display Screen Device
Aspect Ratio
PDP Module
Operating Environment
Storage Environment
Input Voltage
1
2
3
4
5
6
No
Item
Specification
Remark
50 inch Wide Color Display Module
16:9
PDP50H3####,
RGB Closed(Well) Type, Glass Filter(38%)
Pixel Format: 1920 horiz. By 1080 ver.
1) Temp.
: 0 ~ 40deg
2) Humidity : 20 ~ 80%
3) Temp. : -20 ~ 60deg
4) Humidity : 10 ~ 90%
AC100-240V~, 50/60Hz
PDP
LGE SPEC.
Maker LG
Display Screen Device
Aspect Ratio
PDP Module
Operating Environment
Storage Environment
Input Voltage
1
2
3
4
5
6
No
Item
Specification
Remark
60 inch Wide Color Display Module
16:9
PDP60H3####,
RGB Closed(Well) Type, Glass Filter(38%)
Pixel Format: 1920 horiz. By 1080 ver.
1) Temp.
: 0 ~ 40deg
2) Humidity : 20 ~ 80%
3) Temp. : -20 ~ 60deg
4) Humidity : 10 ~ 90%
AC100-240V~, 50/60Hz
PDP
LGE SPEC.
Maker LG
- 6 -
V
Module General Specification
No 
Item 
Min 
Typ 
Max 
Unit 
Remark 
1.    Display area 
1324.8 (H) * 745.2 (V) ±0.5 
mm 
 
2.    Outline dimension 
1390 (W) x 811 (H) x 58 (D) 
±
1
 
mm 
 
3.    Number of Pixels 
1920 (H) x 1080(V)
 
 
1Pixel=3RGB  Cells 
4.    Cell pitch 
230um (H) x 690um (V)
 
u
Green Cell Basis 
5.    Color arrangement 
RGB closed type 
 
 
6.    Weight(net) 
21.5 
22.5 
23.5 
Kg 
Net 1EA 
7.    Weight(gross) 
252 
255 
258 
Kg 
8EA 1Box 
Temperature 
0    ~ 60 
deg 
Humidity 
20 ~ 80 
8.   
Operating 
Environment 
Pressure 
800 ~ 1100 
hPa 
Altitude : 0 to 2000M 
Temperature
 
-20  ~ 60 
deg 
Humidity 
10 ~ 90 
9.   
Storage 
Environment 
Pressure 
700 ~ 1100 
hPa 
Altitude : 0 to 3000M 
Start time 
4.5 
5.5 
min 
 
10.   
Image stick 
minimization 
mode 
Low Brightness 
Arrival Time 
14
16 
min 
 
15 
V
Model General Specification
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
- 7 -
A
Chroma & Brightness (Optical)
(1) FHD module(60H3 module, Glass Filter, 50Hz-This data at 50Hz is about 80% level of 60Hz data)
No
Item
Min
Typ
Max
Unit
Remark
(*) Peak Brightness Mode
- 1/ 100  white window Pattern
(typically 1% window size)
241
284
- 100 IRE (255Gray)
1
White peak Brightness
cd/ m
2
- Picture Mode : Vivid(Mediem)
- Input: HDMI-PC(1920*1080 60Hz)
Peak Brightness Condition may
Slightly different between sets.
126
142
- 25/ 100 white window pattern
- 100% Window White Pattern
2
White average brightness
41
46
cd/ m
2
- 100IRE (255Gray)
- Picture Mode : Vivid (Medium)
3
Brightness uniformity
-15 
+15 
- 85IRE (216Gray) 100% White Pattern 
- Picture Mode: Vivid (Medium)
White
X
0.270 
0.285 
0.300 
Y
0.278 
0.293 
0.308
- White: 85IRE(216Gray)
Red 
X  
0.635 
0.640 
-
100% window white pattern
4
Color
Y
0.318 
0.330 
0.340 
- R/G/B: 100IRE(255Gray)
coordinate
Green
X
0.242 
0.300 
0.305
100% window white pattern
0.595 
0.600 
-
- Picture: Vivid (Medium)
Blue 
0.150 
0.158 
- 100% Window
0.060 
0.070
5
Contrast ratio at dark room
100,000: 1 
1,000,000 :1
- 1/100 White Window Pattern(Peak Mode )
- 100IRE(255Gray)
- Black : Full Black
- Picture Mode : Vivid
6
Color coordinate uniformity
-0.01
Average
+0.01
- 85IRE Full White Pattern
- Picture Mode : Vivid
Cool
0.261 
0.276 
0.291
0.268 
0.283 
0.298
7
Colour
Medium 
0.270
0.285
0.300
- 85IRE Full White Pattern
Temperature
0.278 
0.293 
0.308
- Picture Mode : Vivid
Warm
0.298 
0.313 
0.328
0.314 
0.329 
0.344
- 8 -
ADJUSTMENT INSTRUCTION
1. Application
This spec. sheet is applied to all of the PE91A chassis.
2. Specification
[Caution: The module keeping condition]
1.  The  module  keeping  condition:  The  normal  temperature
condition(more than 15°C)
--> Immediately the line supply.
2. The module keeping condition: 0°C
-->  The module must be kept for more than 2 hours at the
normal temperature.
3. The module keeping condition: -20°C
-->  The module must be kept for more than 3 hours at the
normal temperature.
4. The case of Gu-mi factory at the winter season.
-->    The  module  must  be  kept  for  more  than  5  minutes  at
the heating zone(40°C~45°C).
(1)  The  adjustment  is  according  to  the  order  which  is
designated  and  which  must  be  followed,  according  to  the
plan which can be changed only on agreeing.
(2) If there is no specific designation, the adjustment must be
performed  in  the  circumstance  of  25±5°C  of  temperature
and 65±10% of relative humidity.
(3)  The  input  voltage  of  the  set  must  keep  100~240V,
50/60Hz.
(4) Input signal Unit: Product Specification Standard.
(5) The set must be operated for about 5 minutes prior to the
adjustment.
O
After  turning  on  RGB  Full  Window  pattern  in  HEAT-RUN
Mode, the receiver must be operated.
O
Enter into HEAT-RUN MODE 
1) Press the ‘POWER ON’ button on R/C for adjustment.
2) Press the ‘ADJ’ button on R/C and enter EZ ADJUST
Select “7. Test Pattern” by using 
D
/
E
(CH +/-) and press
ENTER(
V
)
Select  “White”  by  using 
F
/
G
(VOL  +/-)  and  press
ENTER(
V
)
- Set heat run should be activated without a signal generator. 
- Single color patterns (RED / BLUE / GREEN) of HEAT RUN
MODE are used to check a plasma panel. 
-  Caution:  If  you  turn  on  a  still  screen  more  than  20  minutes
(Especially  digital  pattern,  cross  hatch  pattern),  an  after
image may be made in the black level part of the screen.
[Caution] 
- Use ‘power on’ button of a service R/C to power on TV set.
-  Do  not  connect  any  external  input  cable  if  there  is  no  any
specifics.
3. Update S/W using Auto Download
through the USB
Caution:  S/W  version  of  USB  file  (xxx.epk)  must  be  bigger  than
one which is downloaded previously.
(1) Insert the USB stick to the USB socket 
(2)  A  downloaded  file  in  USB  stick  will  be  detected
automatically.
(3)  If  S/W  version  of  USB  file  (xxx.epk)  is  bigger  than  one
which  is  downloaded  previously,  the  message,  “Copying
files from memory”, will appear. 
(4)  If  an  update  procedure  was  completed,  TV  set  will  be
turned off and on automatically.
(5) If TV set is turned on, check an updated version.
* If a downloaded version is more bigger than one of which
TV  set  had,  TV  set  can  lost  channel  data.  In  this  case,
you have to scan channels again. 
4. After Downloading S/W, Adjust 
TOOL OPTION
(1) Push “IN-START” button on a service R/C.
(2) Select “Tool Option 1” and Push “OK” button.
(3) Put the number of a below table in order of a suffix of the
“Tool Option(X)”. 
(Each model has a different number.)
Model 
Tool Option1 Tool Option2 Tool Option3 Tool Option4 
42PQ60D-GA 
24768 
2120 
51436 
4352 
50PQ60D-GA 
37056 
2120 
51436 
4352 
50PS80FD-GA 
37248 
3144 
 
51440 
4352
50PS30FD-GA 
36928 
2120 
51436 
4352 
60PS80FD-GA 
49536 
3144 
51440 
4352 
Page of 45
Display

Click on the first or last page to see other 60PS80FD-GA (CHASSIS:PE91A) service manuals if exist.