LG 60PS80FD-GA (CHASSIS:PE91A) Service Manual ▷ View online
- 5 -
V
Module Specification
(1) 50” FHD
(2) 60” FHD
Display Screen Device
Aspect Ratio
PDP Module
Operating Environment
Storage Environment
Input Voltage
1
2
3
4
5
6
No
Item
Specification
Remark
50 inch Wide Color Display Module
16:9
PDP50H3####,
RGB Closed(Well) Type, Glass Filter(38%)
Pixel Format: 1920 horiz. By 1080 ver.
1) Temp.
: 0 ~ 40deg
2) Humidity : 20 ~ 80%
3) Temp. : -20 ~ 60deg
4) Humidity : 10 ~ 90%
AC100-240V~, 50/60Hz
PDP
LGE SPEC.
Maker LG
Display Screen Device
Aspect Ratio
PDP Module
Operating Environment
Storage Environment
Input Voltage
1
2
3
4
5
6
No
Item
Specification
Remark
60 inch Wide Color Display Module
16:9
PDP60H3####,
RGB Closed(Well) Type, Glass Filter(38%)
Pixel Format: 1920 horiz. By 1080 ver.
1) Temp.
: 0 ~ 40deg
2) Humidity : 20 ~ 80%
3) Temp. : -20 ~ 60deg
4) Humidity : 10 ~ 90%
AC100-240V~, 50/60Hz
PDP
LGE SPEC.
Maker LG
- 6 -
V
Module General Specification
No
Item
Min
Typ
Max
Unit
Remark
1. Display area
1324.8 (H) * 745.2 (V) ±0.5
mm
2. Outline dimension
1390 (W) x 811 (H) x 58 (D)
±
1
mm
3. Number of Pixels
1920 (H) x 1080(V)
1Pixel=3RGB Cells
4. Cell pitch
230um (H) x 690um (V)
um
Green Cell Basis
5. Color arrangement
RGB closed type
6. Weight(net)
21.5
22.5
23.5
Kg
Net 1EA
7. Weight(gross)
252
255
258
Kg
8EA 1Box
Temperature
0 ~ 60
deg
Humidity
20 ~ 80
%
8.
Operating
Environment
Environment
Pressure
800 ~ 1100
hPa
Altitude : 0 to 2000M
Temperature
-20 ~ 60
deg
Humidity
10 ~ 90
%
9.
Storage
Environment
Environment
Pressure
700 ~ 1100
hPa
Altitude : 0 to 3000M
Start time
4.5
5
5.5
min
10.
Image stick
minimization
mode
minimization
mode
Low Brightness
Arrival Time
14
16
min
15
V
Model General Specification
- 7 -
A
Chroma & Brightness (Optical)
(1) FHD module(60H3 module, Glass Filter, 50Hz-This data at 50Hz is about 80% level of 60Hz data)
No
Item
Min
Typ
Max
Unit
Remark
(*) Peak Brightness Mode
- 1/ 100 white window Pattern
(typically 1% window size)
241
284
- 100 IRE (255Gray)
1
White peak Brightness
cd/ m
2
- Picture Mode : Vivid(Mediem)
- Input: HDMI-PC(1920*1080 60Hz)
Peak Brightness Condition may
Slightly different between sets.
126
142
- 25/ 100 white window pattern
- 100% Window White Pattern
2
White average brightness
41
46
cd/ m
2
- 100IRE (255Gray)
- Picture Mode : Vivid (Medium)
3
Brightness uniformity
-15
0
+15
- 85IRE (216Gray) 100% White Pattern
- Picture Mode: Vivid (Medium)
White
X
0.270
0.285
0.300
Y
0.278
0.293
0.308
- White: 85IRE(216Gray)
Red
X
0.635
0.640
-
100% window white pattern
4
Color
Y
0.318
0.330
0.340
- R/G/B: 100IRE(255Gray)
coordinate
Green
X
0.242
0.300
0.305
100% window white pattern
Y
0.595
0.600
-
- Picture: Vivid (Medium)
Blue
X
-
0.150
0.158
- 100% Window
Y
-
0.060
0.070
5
Contrast ratio at dark room
100,000: 1
1,000,000 :1
- 1/100 White Window Pattern(Peak Mode )
- 100IRE(255Gray)
- Black : Full Black
- Picture Mode : Vivid
6
Color coordinate uniformity
-0.01
Average
+0.01
- 85IRE Full White Pattern
- Picture Mode : Vivid
Cool
X
0.261
0.276
0.291
Y
0.268
0.283
0.298
7
Colour
Medium
X
0.270
0.285
0.300
- 85IRE Full White Pattern
Temperature
Y
0.278
0.293
0.308
- Picture Mode : Vivid
Warm
X
0.298
0.313
0.328
Y
0.314
0.329
0.344
- 8 -
ADJUSTMENT INSTRUCTION
1. Application
This spec. sheet is applied to all of the PE91A chassis.
2. Specification
[Caution: The module keeping condition]
1. The module keeping condition: The normal temperature
condition(more than 15°C)
--> Immediately the line supply.
--> Immediately the line supply.
2. The module keeping condition: 0°C
--> The module must be kept for more than 2 hours at the
normal temperature.
3. The module keeping condition: -20°C
--> The module must be kept for more than 3 hours at the
normal temperature.
4. The case of Gu-mi factory at the winter season.
--> The module must be kept for more than 5 minutes at
the heating zone(40°C~45°C).
(1) The adjustment is according to the order which is
designated and which must be followed, according to the
plan which can be changed only on agreeing.
plan which can be changed only on agreeing.
(2) If there is no specific designation, the adjustment must be
performed in the circumstance of 25±5°C of temperature
and 65±10% of relative humidity.
and 65±10% of relative humidity.
(3) The input voltage of the set must keep 100~240V,
50/60Hz.
(4) Input signal Unit: Product Specification Standard.
(5) The set must be operated for about 5 minutes prior to the
(5) The set must be operated for about 5 minutes prior to the
adjustment.
O
After turning on RGB Full Window pattern in HEAT-RUN
Mode, the receiver must be operated.
O
Enter into HEAT-RUN MODE
1) Press the ‘POWER ON’ button on R/C for adjustment.
2) Press the ‘ADJ’ button on R/C and enter EZ ADJUST
2) Press the ‘ADJ’ button on R/C and enter EZ ADJUST
Select “7. Test Pattern” by using
D
/
E
(CH +/-) and press
ENTER(
V
)
Select “White” by using
F
/
G
(VOL +/-) and press
ENTER(
V
)
- Set heat run should be activated without a signal generator.
- Single color patterns (RED / BLUE / GREEN) of HEAT RUN
- Single color patterns (RED / BLUE / GREEN) of HEAT RUN
MODE are used to check a plasma panel.
- Caution: If you turn on a still screen more than 20 minutes
(Especially digital pattern, cross hatch pattern), an after
image may be made in the black level part of the screen.
image may be made in the black level part of the screen.
[Caution]
- Use ‘power on’ button of a service R/C to power on TV set.
- Do not connect any external input cable if there is no any
- Use ‘power on’ button of a service R/C to power on TV set.
- Do not connect any external input cable if there is no any
specifics.
3. Update S/W using Auto Download
through the USB
Caution: S/W version of USB file (xxx.epk) must be bigger than
one which is downloaded previously.
(1) Insert the USB stick to the USB socket
(2) A downloaded file in USB stick will be detected
(2) A downloaded file in USB stick will be detected
automatically.
(3) If S/W version of USB file (xxx.epk) is bigger than one
which is downloaded previously, the message, “Copying
files from memory”, will appear.
files from memory”, will appear.
(4) If an update procedure was completed, TV set will be
turned off and on automatically.
(5) If TV set is turned on, check an updated version.
* If a downloaded version is more bigger than one of which
TV set had, TV set can lost channel data. In this case,
you have to scan channels again.
you have to scan channels again.
4. After Downloading S/W, Adjust
TOOL OPTION
(1) Push “IN-START” button on a service R/C.
(2) Select “Tool Option 1” and Push “OK” button.
(3) Put the number of a below table in order of a suffix of the
(2) Select “Tool Option 1” and Push “OK” button.
(3) Put the number of a below table in order of a suffix of the
“Tool Option(X)”.
(Each model has a different number.)
(Each model has a different number.)
Model
Tool Option1 Tool Option2 Tool Option3 Tool Option4
42PQ60D-GA
24768
2120
51436
4352
50PQ60D-GA
37056
2120
51436
4352
50PS80FD-GA
37248
3144
51440
4352
50PS30FD-GA
36928
2120
51436
4352
60PS80FD-GA
49536
3144
51440
4352
Click on the first or last page to see other 60PS80FD-GA (CHASSIS:PE91A) service manuals if exist.