● When Color temperature (White balance) Adjustment
(Automatically)
- Press “Power only key” of service remocon and operate
automatically adjustment.
- Set BaudRate to 115200.
● You must start “wb 00 00” and finish it “wb 00 ff”.
● If it needs, then adjustment “Offset”.
■ White Balance Adjustment (Manual adjustment)
● Test Equipment: CA-210
- Using PDP color temperature, Color Analyzer (CA-210)
must use CH 10, which Matrix compensated (White, Red,
Green, Blue compensation) with CS-2100. See the
Coordination bellowed one.
● Manual adjustment sequence is like bellowed one.
- Turn to “Ez-Adjust” mode with press ADJ button of service
remocon.
- Select “10.Test Pattern” with CH+/- button and press
enter. Then set will go on Heat-run mode. Over 30
minutes set let on Heat-run mode.
- Let CA-210 to zero calibration and must has gap more
10cm from center of PDP module when adjustment.
- Press “ADJ” button of service remocon and select
“7.White-Balance” in “Ez-Adjust” then press “►” button of
navigation key. (When press “►” button then set will go to
full white mode)
- Adjust at three mode (Cool, Medium, Warm)
- If “cool” mode
Let B-Gain to 192 and R, G, B-Cut to 64 and then control
R, G gain adjustment High Light adjustment.
- If “Medium” and “Warm” mode Let R-Gain to 192 and R,
G, B-Cut to 64 and then control G, B gain adjustment
High Light adjustment.
- All of the three mode
Let R-Gain to 192 and R, G, B-Cut to 64 and then control
G, B gain adjustment High Light adjustment.
- With volume button (+/-) you can adjust.
- After all adjustment finished, with Enter (■ key) turn to
Ez-Adjust mode. Then with ADJ button, exit from
adjustment mode
* Attachment: White Balance adjustment coordination and
color temperature.
● Using CS-1000 Equipment.
- COOL : T=11000K, ∆uv=0.000, x=0.276 y=0.283
- MEDIUM : T=9300K, ∆uv=0.000, x=0.285 y=0.293
- WARM : T=6500K, ∆uv=0.000, x=0.313 y=0.329
● When tester will measure on Cool condition, adjust W30 on
TV display menu.
● When tester will measure on medium condition, adjust 0 on
TV display menu.
● When tester will measure on warm condition, adjust W30 on
TV display menu.
● Using CA-210 Equipment. (10 CH)
- Contrast value: 216 Gray
- Brightness spec.
5.3. Test of RS-232C control.
- Press In-Start button of Service Remocon then set the
“4.Baud Rate” to 115200. Then check RS-232C control and
5.4. Selection of Country option.
model (Not allowed Korean model). It is selection of Country
about Rating and Time Zone.
■ Models: All models which PU31A Chassis (See the first
page.)
■ Press “In-Start” button of Service Remocon, then enter the
“Option” Menu with “PIP CH-“ Button
■ Select one of these three (USA, CANADA, MEXICO) de-
pends on its market using “Vol. +/-“button.
* Caution : Don’t push The INSTOP KEY after completing the
function inspection.
* Caution : Inspection only PAL M / NTSC
Color
temperature
Test
Equipment
Color Coordination
x
y
COOL
CA-210
0.276 ± 0.002 0.283 ± 0.002
MEDIUM
CA-210
0.285 ± 0.002 0.293 ± 0.002
WARM
CA-210
0.313 ± 0.002 0.329 ± 0.002
Item
White average
brightness
Brightness uniformity
Min
49
-20
Typ
60
Max
+20
Unit
cd/m²
%
Remark - 100% Window White
Pattern
- 100IRE(255Gray)
- Picture: Vivid(Medium)
- 85IRE(216Gray) 100%
Window White Pattern
- Picture: Vivid(Medium)
- 10 -
6. GND and ESD Testing
6.1. Prepare GND and ESD Testing.
■ Check the connection between set and power cord
6.2. Operate GND and ESD auto-test.
■ Fully connected (Between set and power cord) set enter the
Auto-test sequence.
■ Connect D-Jack AV jack test equipment.
■ Turn on Auto-controller(GWS103-4)
■ Start Auto GND test.
■ If its result is NG, then notice with buzzer.
■ If its result is OK, then automatically it turns to ESD Test.
■ Operate ESD test
■ If its result is NG, then notice with buzzer.
■ If its result is OK, then process next steps. Notice it with
Good lamp and STOPER Down.
6.3. Check Items.
■ Test Voltage
● GND: 1.5KV/min at 100mA
● Signal: 3KV/min at 100mA
■ Test time: just 1 second.
■ Test point
● GND test: Test between Power cord GND and Signal
cable metal GND.
● ESD test: Test between Power cord GND and Live and
neutral.
■ Leakage current: Set to 0.5mA(rms)
6.4. POWER PCB Ass’y Voltage adjustment
(Va, Vs voltage adjustment)
6.4.1. Test equipment :
: D.M.M 1EA
6.4.2. Connection Diagram for Measuring
: refer to fig.1
<XPOWER4 60R5 PSU>
6.4.3. Adjustment method
6.4.3.1. Vs adjustment (refer fig.1)
(1) Connect + terminal of D.M.M. to Vs pin of P811, connect
-terminal to GND pin of P811
(2) After turning VR901, voltage of D.M.M adjustment as same
as Vs voltage which on label of panel left/top ( deviation ;
±0.5V)
6.4.3.2. Va adjustment (refer fig.1)
(1) After receiving 100% Full White Pattern, HEAT RUN.
(2) Connect + terminal of D.M.M. to Va pin of P811, connect
-terminal to GND pin of P811
(3) After turning VR502,voltage of D.M.M adjustment as same
as Va voltage which on label of panel left/top (deviation;
±0.5V)
7. Default Service option.
7.1. ADC-Set.
■ R-Gain adjustment Value (default 128)
■ G-Gain adjustment Value (default 128)
■ B-Gain adjustment Value (default 128)
■ R-Offset adjustment Value (default 128)
■ G-Offset adjustment Value (default 128)
■ B-Offset adjustment Value (default 128)
7.2. White balance. Value.
7.3. Temperature Threshold
■ Threshold Down Low
20
■ Threshold Up Low
23
■ Threshold Down High
70
■ Threshold Up High
75
8. USB DOWNLOAD(*.epk file download)
■ Put the USB Stick to the USB socket
■ Press Menu key, and move OPTION
■ Press “FAV” Press 7 times
(fig.1) PCB Assy Voltage adjustment
Center(Default)
COOL
Mid
Warm
R Gain
192
192
192
G Gain
192
192
192
B Gain
192
192
192
R Cut
64
64
64
G Cut
64
64
64
B Cut
64
64
64
- 11 -
■ Select download file (epk file)
■ After download is finished, remove the USB stick.
■ Press “IN-START” key of ADJ remote control, check the
S/W version.
9. Tool option
Model
60PN6500-SC
60PN6500-SX
Tool option 1
49312
Tool option 2
21776
Tool option 3
3313
Tool option 4
50310
Tool option 5
2058
Country code
3
Country Group
BR
Country
N/A
- 12 -
BLOCK DIAGRAM
Click on the first or last page to see other 60PN6500-SC / 60PN6500-SX (CHASSIS:PB31A) service manuals if exist.