- 5 -
V
Model General Specification
No
Item
Specification
Remark
1
Market
2
Broadcasting system
50/60PK*50-AA
PAL B 
DVB-T
50/60PK*50-TA
PAL/SECAM-BG/DK , PAL-I
DVB-T
50/60PK*50R-TA PAL/SECAM-BG/DK, PAL-I
3
Receiving system
Analog : Upper Heterodyne
Digital : COFDM
4
Video Input (2EA)
PAL, SECAM, NTSC
5
Component Input (2EA)
Y/Cb/Cr, Y/ Pb/Pr
6
RGB Input
RGB-PC
Analog (D-Sub 15Pin)
7
HDMI Input (4EA)
HDMI-PC
HDMI1/DVI 1,2,3,4 
HDMI-DTV
Upper 70 tool, 
But under 60 tool HDMI 3EA.
8
Audio Input (5 EA)
RGB/DVI Audio, Component, AV
L/R Input
9
SPDIF Out(1 EA)
SPDIF Out
10
USB(2.0)
For SVC, S/W Download, X-Studio, DivX
11
Bluetooth
Bluetooth Phone(JPEG, MP3), 
Profile : A2DP, BIP, FTP, GAVDP, 
Bluetooth Headset(mono, stereo)
HSP, OPP
Only 50/60PK*50R-TA
12
Ethernet LAN
- 6 -
ADJUSTMENT INSTRUCTION
1. Application Range
This spec sheet is applied to all of the PA02A chassis. 
2. Specification
(1) Because this is not a hot chassis, it is not necessary to use
an  isolation  transformer.  However,  the  use  of  isolation
transformer will help protect test instrument.
(2) Adjustment must be done in the correct order.
(3) The adjustment must be performed in the circumstance of
25 °C ± 5 °C of temperature and 65 % ± 10 % of relative
humidity if there is no specific designation.
(4) The  input  voltage  of  the  receiver  must  keep  100  V  ~  240
V, 50 / 60 Hz.
(5) The receiver must be operated for about 5 minutes prior to
the adjustment when module is in the circumstance of over
15 °C
- In case of keeping module is in the circumstance of 0 °C,
it  should  be  placed  in  the  circumstance  of  above  15  °C
for 2 hours
- In case of keeping module is in the circumstance of below
-20 °C, it should be placed in the circumstance of above
15 °C for 3 hours,.
O
After  RGB  Full  White  in  HEAT-RUN  Mode,  the  receiver
must be operated prior to the adjustment.
O
Enter into HEAT-RUN MODE 
1) Press the POWER ON KEY on R/C for adjustment.
2) OSD display and screen display PATTERN MODE.
- Set is activated HEAT run without signal generator in this
mode. 
- Single color pattern ( WHITE ) of HEAT RUN MODE uses
to check panel. 
- Caution  :  If  you  turn  on  a  still  screen  more  than  20
minutes  (Especially  digital  pattern,  cross  hatch  pattern),
an after image may be occur in the black level part of the
screen.
3. MAC Address.
Except 50PK550-TA model.
* Connect  TV  SET  and  PC  which  download  MAC  Address
Writing program by RS232C-Cable
(1) Start  “MAC+CIKeyl.exe”Program  and  Click  (3)  Button  to
connect TV and PC.
(2) Click (4) to download MAC Address.
(3) When download succeed, you can see “OK” on (6)
* Each  Chassis  has  it’  own  MAC  Address.  Please  be  careful  of
download.
3-2. Ping TEST
* This test is to check Network operation.
(1) Press  "Power  on"  button  of  a  service  R/C.(Baud  rate  :
115200 bps)
(2) Connect RS232-C Signal Cable.
(3). Connect LAN cable to MAIN PCB Assembly.      
(4) When network operates normally, you can see “OK”. 
3-3.  ADC Adjustment
Auto-control adjustment protocol(RS-232C)
(1) Adjustment of RGB
1) Convert to PC in Input-source.
2) Signal equipment displays
Output Voltage:  700 mVp-p
Impress Resolution XGA (1920 x 1080 @ 60Hz) 
Model : 60    in Pattern Generator
Pattern : 65   in Pattern Generator 
(MSPG-925 SERISE) 
3) Adjust by commanding AUTO_COLOR_ADJUST
(2) COMPONENT input ADC 
V
Convert to Component in Input-source.
V
Signal equipment displays
Impress Resolution 480i
MODEL: 209   in Pattern Generator(480i Mode) 
PATTERN : 65  in Pattern Generator
(MSPG-925 SERISE) 
Impress Resolution 1080i
MODEL: 225   in Pattern Generator(1080P Mode)
PATTERN: 65  in Pattern Generator
(MSPG-925 SERISE) 
3-4. Insert Tool OPTION 
and Model Name download.
(1) Press IN_START key on R/C to insert Tool OPTION
(2) On the “ Tool Option ”, Insert Tool Option by a number key
(3) Press the ENTER(
V
)
(4) Press ENTER(
V
) again.
(5) Select “OK to Download” by using 
F
/
G
(VOL +/-) and press
G
(VOL +)
1) 50/60PK**0-AA
2) 50/60PK**0-TA
3) 50/60PK**R-TA
3-5. EDID(The Extended Display
Identification Data) download
(1) Press the ADJ KEY on R/C and enter EZ ADJUST.
(2) Select  “5.EDID  D/L”  by  using 
D
/
E
(CH  +/-)  and  press
ENTER(
V
).
(3) Select “Start” and press navigation key(
G
).
(4) EDID download is executed automatically.
(5) Press EXIT key on R/C
* Caution
- Never  connect  HDMI  &  D-sub  Cable  when  the  user
download EDID .
V
Use the proper cables below for EDID Writing.
* Edid data and Model option download(RS232)
- 7 -
Model 
Country  Tool 
Tool 
Tool 
Tool 
Tool 
Name
Group Value 1 Value 2 Value 3 Value 4 Value 5
50PK950-AA
AU
36864
31831
54920 24940
2866
60PK950-AA
49152
50PK750-AA
36896
60PK750-AA
49184
Model 
Tool 
Tool 
Tool 
Tool 
Tool 
Name
Value 1
Value 2 Value 3
Value 4 Value 5
50PK950-TA
36864
31831
54920
24940
2866
60PK950-TA
49152
50PK750-TA
36896
50PK550-TA
49184
23638
54912
28936
2098
Market
Area Code
Singapore
SG
ZA
Indonesia
ID
Malaysia
MY
A-ASIA
Model 
Country  Tool 
Tool 
Tool 
Tool 
Tool 
Name
Group Value 1 Value 2 Value 3 Value 4 Value 5
31831
63112 24940
2866
60PK950R-TA
49152
50PK760R-TA
37408
Market
Area Code
India
800
- 8 -
* EDID DATA
(1) Analog RGB
(2) HDMI 1
(3) HDMI 2
(4) HDMI 3
(4) HDMI 4
3-6. Confirmation
(1) Press ‘InStart’ Key on Factory SVC Remote Controller. 
And MUST check ADC & EDID ADJ status is OK.
4. SET assembly adjustment method
* Caution : Each  PCB  assembly  must  be  checked  by  check  JIG
set. (Because power PCB Assembly damages to PDP
Module, especially be careful)
4-1.POWER  PCB  Assembly  Voltage
adjustment (Va/Vs Voltage Adjustment)
Test equipment : D.M.M 1EA
Connection Diagram for Measuring : refer to fig.4
Adjustment method 
(1) Va adjustment 
1) Connect  +  terminal  of  D.  M.M.  to  Va  pin  of  P811,
connect -terminal to GND pin of P811.
2) After  turning  VR901,voltage  of  D.M.M  adjustment  as
same  as  Va  voltage  which  on  label  of  panel  right/top
(deviation; ±0.5V)
(2) Vs adjustment 
1) Connect  +  terminal  of  D.  M..M.  to  Vs  pin  of  P811,
connect -terminal to GND pin of P811.
2) After  turning  VR951,  voltage  of  D.M.M  adjustment  as
same  as  Vs  voltage  which  on  label  of  panel  right/top    (
deviation ; ±0.5V)
4-2. Download Serial number (RS-232C)
V
Press “Power on” key of service R/C.
(Baud rate : 115200 bps)
V
Connect RS232 Signal Cable to RS-232 Jack.
V
Write Serial number by use RS-232.
V
Must check the serial number at the Diagnostics of SET UP
menu. 
(Refer to below ‘6.SET INFORMATION’).