LG 60PK200-UA (CHASSIS:PU01A) Service Manual ▷ View online

4. ADC Process
4-1. Auto ADC Process (using DFT)
PC (for communication through RS-232C)     UART Baud rate
: 115200 bps
Command : aa 00 00 (Start factory mode)
Command : ad 00 10 (working Auto ADC)
Command : aa 00 90 (End of Auto ADC Process)
4-2. Manual ADC Process using Service 
Remocon
After  enter  Service  Mode  by  pushing  “ADJ”  key,  execute
“ADC Adjust” by pushing “
G
” key at “0. ADC CALIBRATION”. 
4-3. Confirmation
(1) We  confirm  whether  “0xBF(480i)/0xC8(1080i)”  address  of
EEPROM “0xA2” is “0xAA” or not. 
(2) If  “0xBF(480i)/0xC8(1080i)”  address  of  EEPROM  “0xA2”
isn’t “0xAA”, we adjust once more
(3) We can confirm the ADC values from “0xB9 ~ 0xBE(480i) /
0xC2 ~ (1080i)” addresses in a page “0xA2”
* Manual  ADC  Confirmation  using  Service  Remocon.  After
enter Service Mode by pushing “INSTART” key,
5. DDC EDID Write Confirmation
6. Total Assembly line process 
* Caution  :  Each  PCB  assembly  must  be  checked  by  check  JIG
set.(Because  power  PCB  Assembly  damages  to  PDP  Module,
especially be careful)
* Caution: Set up “RF mode(noise)” before voltage adjustment.
6-1. POWER PCB Ass’y Voltage 
adjustment
(Va, Vs voltage adjustment)
(1) Test equipment : D.M.M 1EA
(2) Connection Diagram for Measuring : refer to fig.1
(fig.1 : Power PCB Assy Voltage adjustment)
6-2. Adjustment method 
(1) Vs adjustment (refer fig.1)
1) Connect  +  terminal  of  D.M.M.  to  Vs  pin  of
P812(42”:P811),  connect  -terminal  to  GND  pin  of
P812(42”:P811)
2) After  turning  VR901,  voltage  of  D.M.M  adjustment  as
same  as  Vs  voltage  which  on  label  of  panel  left/top    (
deviation ; ±0.5V)
(2) Va adjustment (refer fig.1)                                               
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect  +  terminal  of  D.M.M.  to  Va  pin  of
P812(42”:P811),  connect  -terminal  to  GND  pin  of
P811(42”:P812).
3) After  turning  VR502,voltage  of  D.M.M  adjustment  as
same  as  Va  voltage  which  on  label  of  panel  left/top
(deviation; ±0.5V)
- 10 -
<XPOWER4 60R1 PSU>
7. DDC EDID Write
MODEL NAME:  LG TV (Not necessary)
Caution: Please only check write status in Instart-menu
7-1. Manual Download(using DFT)
PC(for  communication  through  RS-232C),  UART  baud  rate:
115200 bps
Command : aa 00 00 (Start Factory mode)
Command : ae 00 10 (Download All EDID)
Command : aa 00 90 (End of Factory mode)
7-2. Manual EDID D/L using Service Remocon
(1) After enter Service Mode by pushing “ADJ” key, select “4.
EDID D/L”.
(2) Finally execute “START” by pushing “
G
” or “
9
”key. 
7-3 Full-HD EDID DATA
RGB EDID DATA
HDMI-1 EDID DATA
HDMI-2 EDID DATA
HDMI-3 EDID DATA
8. Adjustment of White Balance
Caution: Press the POWER ON KEY on R/C before W/B adjustment.
8-1. Test Equipment
- Color Analyzer(CS-1000, CA-100+(CH.10), CA-210(CH.10) )
[ Please adjust CA-100+ / CA-210 by CS-1000 before measuring
--> You should use Channel 10 which is Matrix compensated
(White, Red, Green, Blue revised) by CS-1000 and adjust
in accordance with White balance adjustment coordinate.
O
Color temperature standards according to CSM and Module 
O
Change  target  luminance  and  range  of  the  Auto  adjustment
W/B equipment.
O
White balance adjustment coordinate and color temperature
- 11 -
0.003
0.003
0.003
[ PC (for communication through RS-232C) ==> UART Baud rate : 115200 bps
3uv
0.329±0.002
0.329±0.002
0.329
y
0.313±0.002
0.313±0.002
0.313
x
CA-210 (CH.10)
CA-100+ (CH.10)
CS-1000
Warm
0.000
0.000
0.000
3uv
0.293±0.002
0.293±0.002
0.293
y
0.285±0.002
0.285±0.002
0.285
x
CA-210 (CH.10)
CA-100+ (CH.10)
CS-1000
Medium
0.000
0.000
0.000
3uv
0.283±0.002
0.283±0.002
0.283
y
0.276±0.002
0.276±0.002
0.276
x
CA-210 (CH.10)
CA-100+ (CH.10)
CS-1000
Cool
Target luminance
65
Range
20
- 12 -
8-2. Connecting Picture of the Measuring 
Instrument
(On Automatic control )
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push control R/C ADJ Key‡ Enter the mode
of White-Balance, the pattern will come out.
8-3. Auto-control interface and directions
(1) Adjust  in  the  place  where  the  influx  of  light  like  floodlight
around is blocked. (illumination is less than 10ux).
(2) In  case  of  PDP:  Measure  and  adjust  after  sticking  the
Color  Analyzer  (CA-100+,  CA210  )  to  the  side  of  the
module. 
In  case  of  LCD:  Adhere  closely    the  Color  Analyzer
(CA210)  to  the  module  less  than  10cm  distance,  keep  it
with the surface of the Module and Color Analyzer’s Prove
vertically.(80~100°).
(3) Aging time  
1)  After  aging  start,  keep  the  power  on  (no  suspension  of
power supply) and heat-run over 5 minutes.
2) In case of PDP, keep white pattern using inside pattern.
3) In case of LCD, using ’no signal’ or ‘full white pattern’ or
the others, check the back light on.
O
Auto adjustment Map(RS-232C)
8-4. Manual white Balance 
(1) Press  the  POWER  ON  KEY  on  R/C  for  adjustment  and
heat run over 5 minutes.
(2) Zero  Calibrate  CA-100+  /  CA-210,  and  when  controlling,
stick the sensor to the center of PDP module surface.
(3) Press the ADJ KEY on R/C and enter EZ ASJUST
Select “3.W/B ADJUST” and press ENTER(
V
)
Set test-pattern on and display inside pattern. 
(4) Control is carried out on three color temperatures, COOL,
MEDIUM, WARM.(Control is carried out three times)
< Temperature: COOL >
- R-offset / G-offset / B-offset is set to 128
- Control R-Gain and G-Gain.
- Each gain is limited to 192
< Temperature: MEDIUM >
- R-offset / G-offset / B-offset is set to 128
- Control R-Gain and G-Gain.
- Each gain is limited to 192
< Temperature: WARM >
- R-offset / G-offset / B-offset is set to 128
- Control G-Gain and B-Gain.
- Each gain is limited to 192
9. HDCP SETTING
(Not necessary) 
Caution: Key is saved in external eeprom. 
10. RS-232C 
Press  In-start  key  and  select  4.Baud  Rate  menu.  Check  RS-
232C after changing Baud Rate 115200.
RS-232C COMMAND
CENTER
[CMD ID DATA]
MIN
(DEFAULT)
MAX
Cool Mid
Warm
Cool
Mid
Warm
R Gain
jg
Ja
jd
00
192
192
192
255
G Gain
jh
Jb
je
00
192
192
192
255
B Gain
ji
Jc
jf00
192
192
192
255
R Cut
128
128
128
255
G Cut
128
128
128
255
B Cut
128
128
128
255
11. TOOL OPTION
11-1. Using DFT(Auto)
PC  (for  communication  through  RS-232C)  UART  Baud  rate  :
115200 bps
Command : ab 00 00 DATA(Model Number(hexadecimal))
11-2. Setting Manual
Press  ADJ  R/C  In-start  key  and  select  0.TOOL  OPTION,
Select Model Number by using R/C number(0~9) key or select
Model  Number  by  using 
F
/
G
(VOL  +/-)  in  accordance  with
destination.
Finally press 
9
(enter) key.
12. AREA OPTION
12-1. Using DFT(Auto)
PC  (for  communication  through  RS-232C)  ==>  UART  Baud
rate : 115200 bps
Command : ah 00 00 DATA(Area Number(hexadecimal))
12-2. Setting Manual
Press  ADJ  R/C  In-start  key  and  select  1.AREA  OPTION,
Select  Model  Number  by  using 
F
/
G
(VOL  +/-)  in  accordance
with destination
- 13 -
ITEM
DATA(Model Number)
M
TOOL OPTION
0
42PJ350
1
50PJ350
2
42PJ360     
3
50PJ360     
4
42PJ550     
5
50PJ550     
6
50PK360     
7
50PK550
8
60PK550
10
42PJ250     
11
50PJ250     
12
42PJ340     
13
50PJ340     
14
50PK250
15
60PK250     
16
60PK280     
17
50PK350     
18
50PK540     
19
60PK540     
Page of 56
Display

Click on the first or last page to see other 60PK200-UA (CHASSIS:PU01A) service manuals if exist.