SERVICE MANUAL
CAUTION
BEFORE SERVICING THE CHASSIS,
READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
CHASSIS : PP81C
MODEL : 60PG70FR       
60PG70FR-MB
CH
VOL
MENU
INPUT
ENTER
- 2 -
CONTENTS
CONTENTS ............................................................................................................................... 2
SAFETY PRECAUTIONS ...........................................................................................................3
ADJUSTMENT INSTRUCTION ..................................................................................................4
BLOCK DIAGRAM....................................................................................................................13 
EXPLODED VIEW ................................................................................................................... 15
SVC. SHEET  ................................................................................................................................
- 3 -
SAFETY PRECAUTIONS
Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by      in the
Schematic Diagram and Exploded View. 
It is essential that these special safety parts should be replaced with the same components as recommended in this manual to prevent
X-RADIATION, Shock, Fire, or other Hazards. 
Do not modify the original design without permission of manufacturer.
General Guidance
An  isolation Transformer should always be used during the
servicing of a receiver whose chassis is not isolated from the AC
power line. Use a transformer of adequate power rating as this
protects the technician from accidents resulting in personal injury
from electrical shocks.
It will also protect the receiver and it's components from being
damaged by accidental shorts of the circuitry that may be
inadvertently introduced during the service operation.
If any fuse (or Fusible Resistor) in this monitor is blown, replace it
with the specified.
When replacing a high wattage resistor (Oxide Metal Film Resistor,
over 1W), keep the resistor 10mm away from PCB.
Keep wires away from high voltage or high temperature parts.
Due to high vacuum and large surface area of picture tube,
extreme care should be used in handling the Picture Tube.
Do not lift the Picture tube by it's Neck.
Leakage Current Cold Check(Antenna Cold Check)
With the instrument AC plug removed from AC source, connect an
electrical jumper across the two AC plug prongs. Place the AC
switch in the on position, connect one lead of ohm-meter to the AC
plug prongs tied together and touch other ohm-meter lead in turn to
each exposed metallic parts such as antenna terminals, phone
jacks, etc. 
If the exposed metallic part has a return path to the chassis, the
measured resistance should be between 1M
and 5.2M
When the exposed metal has no return path to the chassis the
reading must be infinite.
An other abnormality exists that must be corrected before the
receiver is returned to the customer.
Leakage Current Hot Check 
(See below Figure) 
Plug the AC cord directly into the AC outlet.
Do not use a line Isolation Transformer during this check. 
Connect 1.5K/10watt resistor in parallel with a 0.15uF capacitor
between a known good earth ground (Water Pipe, Conduit, etc.)
and the exposed metallic parts.
Measure the AC voltage across the resistor using AC voltmeter
with 1000 ohms/volt or more sensitivity.
Reverse plug the AC cord into the AC outlet and repeat AC voltage
measurements for each exposed metallic part. Any voltage
measured must not exceed 0.75 volt RMS which is corresponds to
0.5mA.
In case any measurement is out of the limits specified, there is
possibility of shock hazard and the set must be checked and
repaired before it is returned to the customer.
Leakage Current Hot Check circuit
1.5 Kohm/10W
To Instrument's
exposed 
METALLIC PARTS
Good Earth Ground
such as WATER PIPE,
CONDUIT etc.
AC Volt-meter
IMPORTANT SAFETY NOTICE
0.15uF
- 4 -
ADJUSTMENT INSTRUCTION
1. Application Range
This spec. sheet is applied to all of the PP81C Chassis.
2. Specification
(1) Because this is not a hot chassis, it is not necessary to use
an isolation transformer. However, the use of isolation
transformer will help protect test instrument.
(2) Adjustment must be done in the correct order.
(3) The adjustment must be performed in the circumstance of
25±5
c
C of temperature and 65±10% of relative humidity if
there is no specific designation.
(4) The input voltage of the receiver must keep 100~240V,
50/60Hz.
(5) Before adjustment, execute Heat-Run for 30 minutes at RF
no signal.
3. ADC calibration
3-1. PC input ADC 
(1) Auto RGB Gain/Offset Adjustment
1) Convert to PC in Input-source
2) Signal equipment displays
Output Voltage  :  700  mVp-p
Impress Resolution XGA (1024 x 768 @ 60Hz)
Model : 60    in Pattern Generator
(1024 x 768 @ 60Hz Black and White Pattern)
Pattern : 54   in Pattern Generator (MSPG-925 SERISE) 
[1/2 Black & White Pattern (Refer below picture)].
3) Adjust by commanding AUTO_COLOR_ADJUST(0xF1)
0x00 0x02 instruction.
(2) Confirmation
1) We confirm whether “0xF1(offset), 0xF2(gain)” address of
EEPROM “0xBC” is “0xAA” or not. 
2) If “0xF1”, “0xF2” address of EEPROM “0xBC” isn’t “0xAA”,
we adjust once more
3) We can confirm the ADC values from “0x00~0x05”
addresses in a page “0xBC”
[
Manual ADC process using Service Remocon. After enter
Service Mode by pushing “ADJ” key, execute “Auto-RGB” by
pushing “
G
” key at “Auto-RGB”. 
3-2. COMPONENT input ADC 
(1) Component Gain/Offset Adjustment
1) Convert to Component in Input-source
2) Signal equipment displays
Impress Resolution  720P
MODEL : 217   in Pattern Generator(720P/60Hz 100%
Color Bar Mode)
PATTERN : 65  in Pattern Generator( MSPG-925 SERISE) 
3) Adjust by commanding AUTO_COLOR_ADJUST(0xF1)
0x00 0x02 instruction
(2) Confirmation
1) We confirm whether “0xF3(offset), 0xF4(gain)” address of
EEPROM “0xBC” is “0xAA” or not. 
2) If “0xF3”, “0xF4” address of EEPROM “0xBC” isn’t “0xAA”,
we adjust once more
3) We can confirm the ADC values from “0x06~0x0B”
addresses in a page “0xBC”
[
Manual ADC process using Service Remocon. After enter
Service Mode by pushing “ADJ” key, execute “Auto-RGB” by
pushing “
G
” key at “Auto-RGB”.
<Fig. 1> Adjustment pattern(RGB PC)
Adjustment pattern (COMPONENT)
Page of 30
Display

LG 60PG70FR-MB (CHASSIS:PP81C) Service Manual ▷ Download

  • DOWNLOAD LG 60PG70FR-MB (CHASSIS:PP81C) Service Manual ↓ Size: 6.8 MB | Pages: 30 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG 60PG70FR-MB (CHASSIS:PP81C) in PDF for free, which will help you to disassemble, recover, fix and repair LG 60PG70FR-MB (CHASSIS:PP81C) Plasma. Information contained in LG 60PG70FR-MB (CHASSIS:PP81C) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.