- 10 -
Auto adjustment Map(RS-232C)
13. Adjustment of White Balance
(Manual white Balance)
V  
One of R Gain/ G Gain/ B Gain should be kept on 80, and
others are controlled lowering from 80
(1) Press ‘power on’ of the control R/C, set heat run to white
by pressing and heat run over 15 minutes.(Set: RS-232
Host: PC, Baud Rate: 115200bps, Download: Cortez) 
(2) Zero Calibrate CA-100+, and stick the sensor to the center
of PDP module surface when you adjust.
(3) Double click In-start key on Controlling R/C and get in
‘white balance’.
(4) Set test-pattern on and display inside pattern. Control is
carried out on three color temperature, COOL, MEDIUM,
WARM. (Control is carried out three times.)
(5) When the R/G/B GAIN is 80 on OSD, it is the FULL
DYNAMIC Range of the Module. In order to control white
balance without the saturation of FULL DYNAMIC Range
and DATA, one of R Gain / G Gain / B Gain should be kept
on 80, and other two is controlled lowering from 80.
* Color Temperature: Cool, Medium, Warm
(1) When R GAIN is set to 80
- Control G GAIN and B GAIN by lowering from 80. 
(2) When B GAIN is set to 80
- Control R GAIN and G GAIN by lowering from 80.
(3) When G GAIN is set to 80
- Control R GAIN and B GAIN by lowering from 192.
One of R Gain / G Gain / B Gain should be kept on 80, and
adjust other two lower than 80.
(When R/G/B GAIN are all 80, it is the FULL DYNAMIC
Range of Module) 
14. Input the Shipping Option Data 
1) Push the IN-START key in a Adjust Remocon.
2) Input the Option Number that was specified in the BOM, into
the Shipping area.
3) The work is finished, Push 
V
Key.
15. Set Information(Serial No& Model name)
15-1. Setting up ‘Tool OPTION1,2’
(After setting white balance, this is set)
(1) Press ADJ Key in the R/C for adjustment
(2) Insert Option value by a number key 
(3) Press the Enter Button
15-2. Check the serial number & Model Name
(1) Push the menu button in DTV mode.
- Select the SETUP-> Diagnostics -> To set.
(2) Check the Serial Number.
16. Set factoring condition
(1) This Adjustment is setting factory shipment mode.
(2) Push the IN-STOP key of adjustment remote controller
before the factory shipment.
Type
Baud Rate
115200
Index
R Gain
G Gain
B Gain
R Offset
G Offset
B Offset
Data bit
8
Cmd1 Cmd2
j
a
j
b
j
c
j
d
j
e
j
f
Stop bit
1
Parity
NONE
PD75A/C
Protocol
Setting
Data
Min Value
00(00)
00(00)
00(00)
00(00)
00(00)
00(00)
Max Value
128(80)
128(80)
128(80)
128(80)
128(80)
128(80)
Model
Name
60PF95
Tool
Option1
2379
1977
0
14
2
1
192
Tool
Option2
Area
Option
Option1 Option2 Option3 Option4
- 11 -
TROUBLE SHOOTING GUIDE
1. Power Board 
1-1. The full flowchart for the voltage output
Start check
Manufacture’s model
passage
1. Check the Power Off
status.
Does the whole
screen appear?
Is it 
identical to when the
power is off?
No
Yes
No
Yes
Yes
Yes
Yes
2. Check the Interface
signal status.
Is the Interface 
signal operating?
Yes
3. Check the St-by 5V
signal circuit.
Does the 
low pressure output
appear?
Does the 
St-by 5V signal 
appear?
No
No
Yes
4. Check the 5V Monitor
signal circuit.
Does the 
5V Monitor signal 
appear?
No
7. Check the VSC Vs-ON
signal 
Does the 
high tension output
appear?
Does the 
VSC signal Vs-ON
appear?
No
No
Does the
high tension 
output voltage
occur?
When
removing  the Y B/D
Module input connector,
does output voltage
drop?
When the
Y, Z B/D Module
input connector, does Power
Board high tension 
output voltage drop?
No
No
No
9. Check the Power
Board Output high
tension circuit
Yes
10. Check the Z B/D
Module output circuit
Yes
When 
removing the Z B/D
Module input connector,
does output voltage
drop?
11. Check the Y B/D
Module output circuit
Yes
Yes
8. Check the Vs, Va
voltage output circuit.
Does the 
Vs, Va voltage output
appear?
No
Yes
Yes
5. Check the VSC RL-ON
signal.
Does the 
VSC signal RL-ON
appear?
No
6. Check the VSC low
pressure output
Does the 
VSC low pressure
output appear?
No
- 12 -
1-2. 60” Power Board Structure ( LGIT )
(1) Pin Layout
(2) Pin Spec
- 13 -
2. No Power
(1) Symptom
1) Does not  minute discharge at module. 
2) Non does not come into the front LED. 
(2) Procedure check
Is the power cord plugged in?
Plug in the power cord.
Yes
No
Is the Line Filter and Power
Board Cable connected?
Connect the Cable.
Yes
No
Is the appropriate Fuse(F101) on
the Power Board?
Replace the Fuse.
Yes
No
Is the Power Board and 13P of
VSC Board Cable connected?
Connect the Cable.
Yes
No
After removing the cables, connect them to the Power Board(except the
SC101 connection cable), and change the AC voltage marking to manual.
When ST-BY 5V does not operate, replace the Power Board.
Page of 46