DOWNLOAD LG 55LM4600 (CHASSIS:LT21B) Service Manual ↓ Size: 5.9 MB | Pages: 46 in PDF or view online for FREE

Model
55LM4600 (CHASSIS:LT21B)
Pages
46
Size
5.9 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD
File
55lm4600-chassis-lt21b.pdf
Date

LG 55LM4600 (CHASSIS:LT21B) Service Manual ▷ View online

- 11 -
* USB DOWNLOAD(*.epk file download)
(1) Put the USB Stick to the USB socket.
(2) Automatically detecting update file in USB Stick.
-  If your downloaded program version in USB Stick is Low, 
it didn't work. But your downloaded version is High, USB 
data is automatically detecting
(3) Show the message "Copying files from memory"
(4) Updating is staring.
(5)  After updating is complete, The TV will restart automatically.
(6)  If TV turns on, check your updated version and Tool option. 
(refer to the next page about tool option)
*  If  downloading  version  is  higher  than  your TV  have, TV 
can  lost  all  channel  data.  In  this  case,  you  have  to 
channel recover. If all channel data is cleared, you didn't 
have a DTV/ATV test on production line.
*  After  downloading,  have  to  adjust  Tool 
Option again.
(1) Push "IN-START" key in service remote controller.
(2) Select "Tool Option 1" and Push "OK" button.
(3) Punch in the number. (Each model has their number.)
(4) Completed selecting Tool option.
Model
Module
Tool 
option1
Tool 
option2
Tool 
option3
Tool 
option4
Tool 
option5
47LM5800-DB
LGD
103
2525
9499
13224
5122
42LM5800-DB
LGD
102
2525
9499
13224
7170
32LM5800-DB
LGD
100
35293
9499
13224
5154
55LM4600-DB
LGD
89
2525
9499
13224
5122
47LM4600-DB
LGD
87
2525
9499
13224
5122
42LM3400-DB
LGD
2525
9499
13224
5154
32LM3400-DB
LGD
2525
9499
13224
5154
32LS5600-DA
LGD
340
35293
9499
13224
5154
47LS4600-DA
LGD
327
2525
9499
13224
5122
42LS4600-DA
LGD
326
2525
9499
13224
5122
32LS4600-DA
LGD
324
2525
9499
13224
5154
32LS3500-DA
LGD
292
494
9499
13224
736
32LS3500-DA
AUO
4388
494
9499
13224
736
42LS3400-DA
LGD
494
9499
13224
736
32LS3400-DA
LGD
494
9499
13224
736
42CS560-DA
AUO
4134
494
9243
13224
736
42CS560-DA
LGD
38
494
9243
13224
704
32CS560-DA
LGD
36
494
9243
13224
737
42CS460-DA
LGD
22
494
9243
13224
704
42CS460-DA
AUO
4118
494
9243
13224
736
32CS460-DA
LGD
20
494
9243
13224
736
- 12 -
3.1. ADC Process
3.1.1. ADC
■ Enter Service Mode by pushing “ADJ” key,
Calibration”
=> Caution :  Using  ‘power  on’  button  of  the Adjustment  R/C, 
power on TV.
 ADC Calibration Protocol (RS232C/USB)
NO
Item
CMD 1 CMD 2 Data 0
Enter
Adjust MODE
Adjust 
‘Mode In’
A
A
0
0 When transfer the  
‘Mode In’,
Carry the command.
ADC adjust
ADC 
Adjust
A
D
1
0 Automatically adjust-
ment
(The use of a inter-
nal pattern)
 Adjust Sequence
▪ aa 00 00  [Enter Adjust Mode]
▪ xb 00 40  [Component1 Input (480i)]
▪ ad 00 10  [Adjust 480i Comp1]
▪ xb 00 60  [RGB Input (1024*768)]
▪ ad 00 10  [Adjust 1024*768 RGB]
▪ aa 00 90  End Adjust mode
* Required equipment : Adjustment R/C. 
3.2. Function Check
3.2.1. Check display and sound 
■ Check Input and Signal items. (cf. work instructions)
(1) TV
(2) AV (CVBS)
(3) COMPONENT (480i)
(4) RGB (PC : 1024 x 768 @ 60hz)
(5) HDMI
(6) PC Audio In 
* Display and Sound check is executed by Remote controller.
3.2.2. MAC Address 
3.2.2.1. Equipment & Condition
▪ Play file: Serial.exe
▪ MAC Address edit
▪ Input Start / End MAC address
3.2.2.2 Download method
3.2.2.2.1. Communication Prot connection
Connect: 
Connection :  PCBA  (USB  Port)  ->  USB  to  Serial  Adapter 
(UC-232A) -> RS-232C cable -> PC(RS-232C port)
3.2.2.2.2. MAC Address Download
▪ Com 1,2,3,4 and 115200(Baudrate)
    
- 13 -
3.2.3. LAN Inspection 
3.2.3.1. Equipment & Condition
▪ Each other connection to LAN Port of IP Hub and Jig
3.2.3.2. LAN inspection solution
▪ LAN Port connection with PCB
▪ Network setting at MENU Mode of TV
▪ setting automatic IP
▪ Setting state confirmation
▪  If  automatic  setting  is  finished,  you  confirm  IP  and  MAC 
Address.
3.2.4. LAN PORT INSPECTION(PING TEST) 
3.2.4.1. Equipment setting
1) Play the LAN Port Test PROGRAM.
2) Input IP set up for an inspection to Test 
     Program.
    *IP Number : 12.12.2.2
3.2.4.2. LAN PORT inspection (PING TEST)
 1) Play the LAN Port Test Program.
 2) connect each other LAN Port Jack.
 3) Play Test (F9) button and confirm OK Message.
 4) Remove LAN CABLE
3.2.5. Model name & Serial number Download
3.2.5.1. Model name & Serial number D/L
■  Press  “Power  on”  key  of  service  remocon.(Baud  rate  : 
115200 bps)
■ Connect RS232C/USB cable to Side USB Jack.
■ Write Serial number by use RS-232C to Side USB.
■ Must check the serial number at Instart menu. 
3.2.5.2.  Method & notice
(1) Serial number D/L is using of scan equipment.
(2)  Setting  of  scan  equipment  operated  by  Manufacturing 
Technology Group.
(3)  Serial number D/L must be conformed when it is produced 
in production line, because serial number D/L is mandatory 
by D-book 4.0
 Manual Download (Model Name and Serial Number)
If  the  TV  set  is  downloaded  By  OTA  or  Service  man, 
Sometimes model name or serial number is initialized.
(Not always) It is impossible to download by bar code scan, so 
It need Manual download.
▪ Press the ‘instart’ key of ADJ remote controller.
▪ Go to the menu ‘6.Model Number D/L’ like below photo.
▪  Input  the  Factory  model  name(ex  42LD450-TA)  or  Serial 
number like photo
▪  Check  the  model  name  Instart  menu  ->  Factory  name 
displayed (ex 42LE7500-TA)
▪  Check  the  Diagnostics  (DTV  country  only)  ->  Buyer  model 
displayed (ex 42LE7500-TA)
=> Caution :  Not to push the INSTOP KEY after completion if 
the function inspection.
- 14 -
4. Total Assembly line process
4.1. Adjustment Preparation
■ W/B Equipment condition
    CA210 :  CH 9, Test signal : Inner pattern (80IRE) – in case of 
CCFL back light
    CA210 :  CH14, Test signal : Inner pattern (80IRE) – in case of 
LED back light
■  Above 5 minutes H/run in the inner pattern. (“power on” key of 
adjust remote control)
Color
Temperature
Cool
13,000k K
X=0.269
(±0.002)
Y=0.273
(±0.002) 42/32CS560-DA
42/32CS460-DA
42/32LS4600-DA
(except LGD 
moduel)
<Test signal>
Inner pattern
(204 Gray
80IRE)
Medium 9,300k K
X=0.285
(±0.002)
Y=0.293
(±0.002)
Warm
6,500k K
X=0.313
(±0.002)
Y=0.329
(±0.002)
■  In case of Edge LED module, the color coordinates is changing 
by aging, so you have to use the below table.
H/R Time(Min)
Cool
Medium
Warm
LED Module(LGD).
x
y
x
x
y
x
269 273 285 293 313 329
1
0-2 min
280 291 296 311 319 340
2
3-5 min
278 288 294 308 317 338
3
6-9 min
276 285 292 305 315 335
4
10-19 min
274 282 290 302 313 332
5
20-35 min
273 279 289 299 312 329
6
36-49 min
270 276 287 296 310 326
7
50-79 min
269 273 286 293 308 323
8 Over 80 min 269 273 285 293 308 323
  Connecting picture of the measuring instrument 
     (On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to 
auto controller or push Adjustment R/C POWER-ON -> Enter 
the mode of White-Balance, the pattern will come out.
 Auto-control interface and directions
(1)  Adjust  in  the  place  where  the  influx  of  light  like  floodlight 
around is blocked. (Illumination is less than 10ux).
(2)  Adhere closely  the Color Analyzer ( CA210 ) to the module 
less  than  10cm  distance,  keep  it  with  the  surface  of  the 
Module and Color Analyzer’s Prove vertically.(80~100°).
(3) Aging time
-  After  aging  start,  keep  the  power  on  (no  suspension  of 
power supply) and heat-run over 5 minutes.
-  Using ‘no signal’ or ‘full white pattern’ or the others, check 
the back light on.
● Auto adjustment Map(RS-232C)
   RS-232C COMMAND
   [ CMD    ID    DATA ]    
       Wb     00       00       White Balance Start
       Wb     00       ff        White Balance End  
RS-232C COMMAND
[CMD ID DATA]
MIN
CENTER
(DEFAULT)
MAX
Cool
Mid
Warm
Cool
Mid
Warm
R Gain
jg
Ja
jd
00
172
192
192
192
G Gain
jh
Jb
je
00
172
192
192
192
B Gain
ji
Jc
jf
00
192
192
172
192
R Cut
64
64
64
128
G Cut
64
64
64
128
B Cut
64
64
64
128
** Caution **
Color Temperature : COOL, Medium, Warm.
One  of  R  Gain/G  Gain/  B  Gain  should  be  kept  on  0xC0,  and 
adjust other two lower than C0.
(when R/G/B Gain are all C0, it is the FULL Dynamic Range of  
Module)
*Manual W/B process using adjusts Remote control.
■After enter Service Mode by pushing “ADJ” key,
■Enter White Balance by pushing “►” key at “7. White Balance”.
  After  You  finish  all  adjustments,  Press  “In-start”  button  and 
compare Tool option and Area option value with its BOM, if it is 
correctly same then unplug the AC cable.
     If it is not same, then correct it same with BOM and unplug AC 
cable.  For  correct  it  to  the  model’s  module  from  factory  JIG 
model.
  Push  The  “IN  STOP  KEY”  after  completing  the  function 
inspection. And Mechanical Power Switch must be set “ON”. 
Page of 46
Display

Click on the first or last page to see other 55LM4600 (CHASSIS:LT21B) service manuals if exist.