LG 50PZ570B-SB (CHASSIS:PB12A) Service Manual ▷ View online
■ Power check
1. PSU voltage check
1. Power-Up Boot Fail Trouble Shooting
L501 : Multi 5V
L503 : 17V
L504 : 5V ST
2. BCM IC power check
■ BCM 0.9V (IC501)
Measure point
Typ. 0.95V
■ BCM 3.3V (IC505)
Measure point
Typ. 3.35V
■ BCM 2.5V (IC502)
Measure point
Typ. 2.54V
■ BCM 1.5V (IC504)
Measure point
Typ. 2.54V
1. Power-Up Boot Fail Trouble Shooting
3. 3D block & Tuner block power check
■ 3D 1V (IC1700)
Measure point
Typ. 1.01V
■ 3D 1.8V (IC1704)
Measure point
Typ. 1.80V
■ Tuner 7V (IC500)
Measure point
Typ. 1.80V
■ Tuner 1.26V (IC2103)
Measure point
Typ. 1.26V
1. Power-Up Boot Fail Trouble Shooting
■ PSU protection check
1. Power-Up Boot Fail Trouble Shooting
■ OVP : Over-voltage protection
UVP : Under-voltage protection
OCP : Over-current protection
Click on the first or last page to see other 50PZ570B-SB (CHASSIS:PB12A) service manuals if exist.