LG 50PZ550-ZA / 50PZ550A-ZA / 50PZ550N-ZA (CHASSIS:PD11A) Service Manual ▷ View online

ⓒ LG Electronics. Inc.2010
Making 
전자 - 6-2
Revision 
4/10
PDP TV
Symptom
A. Picture Problem
Picture broken/Freezing
Repair Process
Y
A21
4
N
Check RF Signal level
Normal 
Signal?
Check RF Cable 
Connection
1. Reconnection
2. Install Booster
Check whether other equipments have problem or not.
(By connecting RF Cable at other equipment)
→ DVD Player ,Set-Top-Box, Different maker TV etc
■ Menu→Setup →Booster
. By using Digital signal level meter
. By using Diagnostics menu on OSD
( Menu→Press red key on R/C →Signal TEST)
- Signal strength (Normal : over 50%)
- Signal Quality  (Normal: over 50%)
Normal 
Picture?
Y
N
Normal 
Picture?
Y
Close
N
N
Check
S/W Version
Booster menu
OnOff: Check
Off
On: Check
S/W Upgrade
SVC 
Bulletin?
Check
Tuner & replace
Main B/D
Normal 
Picture?
Y
N
Y
Close
Normal 
Picture?
Y
Close
N
A6-1, 2
Normal 
Picture?
N
Contact with signal 
distributor or 
broadcaster 
(Cable or Air)
Move 
No Picture/ Sound Ok
Section
2010. 11. 16
ⓒ LG Electronics. Inc.2010
Making 
전자 - 6-2
Revision 
5/10
PDP TV
Symptom
A. Picture Problem
Vertical bar/ Horizontal Bar
Repair Process
Check
defect type
Y
N
Y
5
Vertical
Line/Bar
Regular 
Vertical
Line / Bar
Check Module pattern 
by using “TILT” key
on SVC R/C
A1
Normal 
Pattern?
1.Check CTRL B/D
2.Replace Board
A13
Replace
Module 
Irregular 
Vertical
Line / Bar
1.Check CTRL B/D
2.Replace Board
Normal 
Picture?
Check Main B/D
Replace  Module
(If Main B/D doesn’t cause)
N
Y
Close
1.Connector re-connection
2.Eliminate foreign material on Connector
N
A13
※CTRL B/D: Control board
Check connection
of Connector
(COF,TCP)
on CTRL B/D , X B/D
Check connection
of Connector (FFC)
on Y Drive B/D 
A20
A20
1.Connector re-connection
2.Eliminate foreign material  on FFC
1. Check Y Drive B/D
2. Replace Board     
A16
Normal 
Picture?
N
Y
Close
Replace
Module 
1.Check CTRL B/D
2.Replace Board
Normal 
Picture?
N
Y
Close
N
Y
Normal
Horizontal
Line/Bar
Normal
Half
No picture
1.Check X B/D
2.Replace Board
Normal 
Picture?
A18
Y
Close
Replace
Module 
N
※ H-Line’s Cause is rare CTRL B/D
A19
2010. 11. 16
ⓒ LG Electronics. Inc.2010
Making 
전자 - 6-2
Revision 
6/10
PDP TV
Symptom
B. Power Problem
No Power (Not turn on)
Repair Process
Y
N
Y
N
. Stand-By: Red
. Operating: Blue
6
Power LED
ON?
Check
R/C IR Operation
Normal
A26
Check
Power LED
DC Power on
by pressing Power Key
On Remote control
Normal
Close
Y
N
Y
Repair/Replace
IR B/D
N
Check Power cord 
was inserted properly
N
Normal
?
Close
Y
Check ST-BY 5V
on Power Board
Normal
Voltage?
A22
N
Normal
Signal?
Y
Check Power B/D
Replace Power B/D
Check
AC DET Signal
on Power B/D
A22
Check
RL_ON Signal
on Power B/D
N
Normal
Signal?
Y
Check Main B/D
Replace Main B/D
Check
the other pin’s
Output voltage
on Power B/D
Normal
Close
Y
N
Replace
Power B/D
A22
A22
A23
2010. 11. 16
ⓒ LG Electronics. Inc.2010
Making 
전자 - 6-2
Revision 
7/10
PDP TV
Symptom
B. Power Problem
Turn off (Instant, under watching)
Repair Process
Instant
Turn off
Turn on after pull out connector
between Power B/D & Y-Sus
N
Power LED
Blue?
Y
Check Power B/D
Replace Power B/D
A23
1. Check Y-Sus/ Z-Sus Board
(especially Short or Open)
2. Replace defective B/D
A8~A11
※ To check Power B/D Protection
Check
Power Off History
RCU Off
7
Turn off
Under watching
“Off Timer”
Set?
A24
“Off timer”
Function off
KEY Off
2HOUR  Off
NO Signal Off
Y
N
Don’t appear
Power Off History
Move 
No Power problem
Section
This is not problem
Normal operation
2010. 11. 16
Page of 73
Display