DOWNLOAD LG 50PV350T-ZD (CHASSIS:PD11L) Service Manual ↓ Size: 9.21 MB | Pages: 72 in PDF or view online for FREE

Model
50PV350T-ZD (CHASSIS:PD11L)
Pages
72
Size
9.21 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / Plasma
File
50pv350t-zd-chassis-pd11l.pdf
Date

LG 50PV350T-ZD (CHASSIS:PD11L) Service Manual ▷ View online

- 5 -
V
Model General Specification
No
Item
Specification
Remarks
1
Market
Albania, Austria, Belgium, Bosnia, Bulgaria, Coratia, 
36 Country
Czech, Denmark, Estonia, Finland, France, Germany, 
Greece, Hungary, Ireland, Italy, Kazakhstan, Latvia, 
Lithuania, Luxembourg, Morocco, Netherlands, Norway, 
Poland, Portugal, Romania, Russia, Serbia, Slovenia, 
Spain, Sweden, Slovakia, Switzerland, Turkey, Ukraine, 
UK
2
Broadcasting system
1) PAL/SECAM BG
EU (PAL Market)
2) PAL/SECAM DK
3) PAL 
Ⅰ/Ⅱ
4) SECAM L/L’
5) DVB T 
6) DVB C
3
Receiving system
Analog : Upper Heterodyne
Digital : COFDM
4
Scart Jack (1EA)
PAL, SECAM
5
Video Input (1EA)
PAL, SECAM, NTSC
Side AV
6
Component Input (1EA)
Y/Cb/Cr, Y/ Pb/Pr
7
RGB Input
RGB-PC
Analog (D-Sub 15Pin)
8
HDMI Input (4EA)
HDMI-PC
HDMI/DVI,HDMI2, HDMI3 
HDMI-DTV
9
Audio Input (3 EA)
RGB/DVI Audio, Component, AV
L/R Input
10
SPDIF Out(1 EA)
SPDIF Out
11
USB(1EA)
For SVC, S/W Download, DivX
12
LAN
For UK models
- 6 -
ADJUSTMENT INSTRUCTION
1. Application Range
This spec sheet is applied to all of the PDP TV with PD11L
chassis. 
2. Specification
(1) The adjustment is according to the order which is
designated and which must be followed, according to the
plan which can be changed only on agreeing.
(2) Power adjustment : Free Voltage. (100 V ~ 240 V, 50 Hz /
60 Hz.)
(3) Magnetic Field Condition: Nil.
(4) Input signal Unit: Product Specification Standard.
(5) Reserve after operation: Above 5 Minutes (Heat Run)
Temperature : at 25 °C ± 5 °C 
Relative humidity  65 % ± 10 % 
Input voltage : 220 V,  60 Hz.
(6) Adjustment equipments : Color Analyzer (CA-210 or CA-
110), DDC Adjustment Jig equipment, SVC remote
controller.
(7) The receiver must be operated for about 5 minutes prior to
the adjustment when module is in the circumstance of over
15 °C
- In case of keeping module is in the circumstance of 0 °C,
it should be placed in the circumstance of above 15 °C
for 2 hours
- In case of keeping module is in the circumstance of below
-20 °C, it should be placed in the circumstance of above
15 °C for 3 hours,.
O
After RGB Full White in HEAT-RUN Mode, the receiver
must be operated prior to the adjustment.
O
Enter into HEAT-RUN MODE 
1) Press the POWER ON KEY on R/C for adjustment.
2) OSD display and screen display PATTERN MODE.
- Set is activated HEAT run without signal generator in this
mode. 
- Single color pattern ( WHITE ) of HEAT RUN MODE uses
to check panel. 
- Caution : If you turn on a still screen more than 20
minutes (Especially digital pattern, cross hatch pattern),
an after image may be occur in the black level part of the
screen.
(8) Push The “IN STOP KEY” - For memory initialiLAtion.
Case1 : Software version up
1) After downloading S/W by USB , TV set will reboot
automatically
2) Push “In-stop” key
3) Push “Power on” key
4) Function inspection
5) After function inspection, Push “In-stop” key.
Case2 : Function check at the assembly line
1) When TV set is entering on the assembly line, Push
“In-stop” key at first.
2) Push “Power on” key for turning it on.
-> If you push “Power on” key, TV set will recover
channel information by itself.
3) After function inspection, Push “In-stop” key.
3. Main PCB check process 
* APC - After Manual-Insert, executing APC
3-1. Boot file Download 
(1) Execute ISP program “Mstar ISP Utility” and then click
“Config” tab.
(2) Set as below, and then click “Auto Detect” and check “OK”
message
If “Error” is displayed, Check connection between computer,
jig, and set.
(3) Click “Read” tab, and then load download file (XXXX.bin)
by clicking “Read”
(4) Click “Connect” tab. If “Can’t” is displayed, Check
connection between computer, jig, and set.
(5) Click “Auto” tab and set as below.
(6) Click “Run”.
(7) After downloadng, check “OK” message.
- 7 -
4. USB DOWNLOAD
(*.epk file download)
(1) Put the USB Stick to the USB socket 
(2) Automatically detecting update file in USB Stick
- If your downloaded program version in USB Stick is Low,
it didn
’t work.
But your downloaded version is High, USB data is
automatically detecting
(3) Show the message 
“Copying files from memory”
(4) Updating is staring.
(5) Updating Completed, The TV will restart automatically.
(6) If your TV is turned on, check your updated version and
Tool option. (explain the Tool option, next stage)
* If downloading version is more high than your TV have,
TV can lost all channel data. In this case, you have to
channel recover. if all channel data is cleared, you didn
’t
have a DTV/ATV test on production line.
* After downloading, have to adjust TOOL OPTION again.
(1) Push "IN-START" key in service remote controller.
(2) Select "Tool Option 1" and Push “OK” button.
(3) Punch in the number. (Each of models has their number.)
(4) Completed selecting Tool option.
5. ADC Process
5-1. ADC
G
” key at “5. ADC
Calibration”
* Caution: Using ‘power on’ button of the Adjustment R/C , power
on TV.
* ADC Calibration Protocol (RS232)
Adjust Sequence
- aa 00 00  [Enter Adjust Mode]
- xb 00 40  [Component1 Input (480i)]
- ad 00 10  [Adjust 480i Comp1]
- xb 00 60  [RGB Input (1024*768)]
- ad 00 10  [Adjust 1024*768 RGB]
- aa 00 90  End Adjust mode
* Required equipment : Adjustment R/C. 
6. Function Check
6-1. Check display and sound
- Check Input and Signal items. (cf. work instructions) 
(1) TV
(2) AV (SCART1/SCART2/ CVBS)
(3) COMPONENT (480i)
(4) RGB (PC : 1024 x 768 @ 60hz)
(5) HDMI
(6) PC Audio In 
* Display and Sound check is executed by Remote
controller.
* Caution : Not to push the INSTOP KEY after completion if the
function inspection.
Model
Module
Tool Tool  Tool  Tool  Tool 
option1 option2   option3  option4 option5
50PV350T-Z* 50R3
37216
21582
54144
28940
544
NO
Item
CMD 1 CMD 2 Data 0
Enter   Adjust 
A
A
0    0
When transfer the
Adjust 
‘Mode In’
‘Mode In’
Mode
Carry the
command.
ADC 
ADC 
A
D
1    0
Automatically
adjust
Adjust
adjustment
(The use of 
a internal pattern)
- 8 -
7. Total Assembly line process
7-1. POWER PCB Assy voltage adjustment
(Vs voltage adjustment)
Required Equipment for adjustment
- D.M.M
Condition for adjustment
- No signal with the snow noise in RF mode)
7-2. Adjustment Preparation
- Required Equipment
O
Remote controller for adjustment 
Color Analyzer ( CS-1000, CA-100,100+,CA-210 or same
product : CH 10 (PDP) 
* Please adjust CA-210, CA-100+ by CS-1000 before
measuring
O
Auto W/B adjustment instrument(only for Auto adjustment)
9 Pin D-Sub Jack(RS232C) is connected to the AUTO W/B
EQUIPMENT.
Before Adjust of White Balance, Please press POWER ONLY
key
Adjust Process will start by execute RS232C Command.
Color temperature standards according to CSM and Module 
O
CS-1000/CA-100+/CA-210(CH 10) 
White balance adjustment coordinates and color temperature.
* Connecting picture of the measuring instrument (On
Automatic control)
- Inside PATTERN is used when W/B is controlled. Connect
to auto controller or push Adjustment R/C POWER-ON
->Enter the mode of White-Balance, the pattern will come
out.
* Auto-control interface and directions
(1) Adjust in the place where the influx of light like floodlight
around is blocked. (Illumination is less than 10ux).
(2) Measure and adjust after sticking the Color Analyzer (CA-
100+, CA210 ) to the side of the module. 
(3) Aging time  
After aging start, keep the Power on (no suspension of
power supply) and heat-run over 5 minutes 
Auto adjustment Map(RS-232C)
RS-232C COMMAND
[ CMD    ID    DATA ]    
Wb     00       00       White Balance Start
Wb     00        ff        White Balance End   
* Caution 
- Color Temperature : COOL, Medium, Warm.
- One of R Gain/G Gain/ B Gain should be kept on 0xC0, and
adjust other two lower than C0.
(when R/G/B Gain are all C0, it is the FULL Dynamic Range
of Module)
* Manual W/B process using adjusts Remote control.
(1) After enter Service Mode by pushing “ADJ” key,
(2) Enter White Balance by pushing “
G
” key at “. White
Balance”
(3) Stick the sensor to the center of the screen and select
each items(Red/Green/Blue Gain) using 
D
/
(CH +/-) key
on R/C.
(4) Adjust R/G/B Gain using 
F
/
(VOL +/-) key on R/C.
(5) Adjust three modes all(Cool/Medium/Warm) : Fix the one
of R/G/B Gain and Change the others.
(6) When the adjustment is completed, Enter “COPY ALL”.
(7) Exit adjustment mode using EXIT key on R/C.
CSM
PLASMA
Cool
11000K
Medium
9300K
Warm
6500K
CSM
Color Coordinate
Temp
±Color Coordinate
x
y
Cool
0.276
0.283
11000K
0.002
Medium
0.285
0.293
9300K
0.002
Warm
0.313
0.329
6500K
0.002
RS-232C COMMAND
CENTER
[CMD ID DATA]
MIN
(DEFAULT)
MAX
Cool Mid
Warm
Cool
Mid
Warm
R Gain
jg
Ja
jd
00
192
192
192
192
G Gain
jh
Jb
je
00
192
192
192
192
B Gain
ji
Jc
jf
00
192
192
192
192
R Cut
64
64
64
128
G Cut
64
64
64
128
B Cut
64
64
64
128
Page of 72
Display