LG 50PT85-ZB (CHASSIS:PD74A) Service Manual ▷ View online

- 5 -
V
Module Specification
Market
Broadcasting system
Receiving system
SCART Jack(2EA)
Video Input (2EA)
S-Video Input (1EA)
Component Input (1EA)
RGB Input
HDMI Input(2EA)
Audio Input(4EA)
1
2
3
4
5
6
7
8
9
10
No
Item
Specification
Remark
UK,France, Germany, Spain, 
Sweden, Finland, Italy
1) PAL-BG
2) PAL - DK
3) PAL - I, I’
4) DVB - T(ID TV)
Analog : Upper Heterodyne
Digital : COFDM
PAL, SECAM
PAL, SECAM, NTSC
PAL, SECAM, NTSC
Y/Cb/Cr, Y/Pb/Pr
RGB-PC
RGB-DTV
HDMI-PC
HDMI-DTV & SOUND
PC Audio, Component, AV(2EA)
UK,France, Germany, Spain, 
Sweden, Finland, Italy
Scart 1 Jack is Full scart and support RF-OUT
(analog)
Scart 2 Jack is Half scart and support MNT-OUT
4 System : PAL, SECAM, NTSC, PAL60
4 System : PAL, SECAM, NTSC, PAL60
L/R Input
- 6 -
ADJUSTMENT INSTRUCTIONS
1. Application Object
These instructions are applied to all of the 50” PLASMA TV,
PD74A Chassis.
2. Note
(1) Because this is not a hot chassis, it is not necessary to use
an  isolation  transformer.  However,  the  use  of  isolation
transformer will help protect test instrument.
(2) Adjustment must be done in the correct order.
(3) The adjustment must be performed in the circumstance of
25±5°C  of  temperature  and  65±10%  of  relative  humidity  if
there is no specific designation.
(4)  The  input  voltage  of  the  receiver  must  keep  100-240V~,
50/60Hz.
(5) Before adjustment, execute Heat-Run for 30 minutes at RF
no signal.
3. Channel memory Setting Method
: You can set channel memory by R/C for adjustment.
1) Press ADJ key of Adjust Remote Controller.(P/N:105-210M)
2)  Select  ‘Channel  Recover’  by  using 
D
/
E
(CH  +/-)  key,  and
press ‘VOL +’.
3) The set is turned off automatically.
4) Press ‘power’ key of Adjust Remote Controller.
4. PCMCIA CARD Checking Method
:  You  must  adjust  DTV  ##(Scrambled)  Channel  and  insert
PCMCIA CARD to socket.
1)  If  PCMCIA  CARD  works  normally,  normal  signals  display
on screen.
But it works abnormally, “No CA module” words display on
screen.
5. POWER PCB Assy Voltage
Adjustments 
(Va, Vs Voltage adjustments)
5-1. Test Equipment :
D.M.M. 1EA
5-2.Connection Diagram for Measuring
: refer to Fig.1
5-3. Adjustment Method
(1) Va Adjustment
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D.M.M to Va pin of P805, connect
- terminal to GND pin of P805.
3)  After  turning  VR901,  voltage  of  D.M.M  adjustment  as
same  as  Va  voltage  which  on  label  of  panel  right/top.
(Deviation; ±0.5V)
(2) Vs Adjustment
1) Connect + terminal of D.M.M to Vs pin of P805, connect
– terminal to GND pin of P805.
2)  After  turning  VR951,  voltage  of  D.M.M  adjustment  as
same  as  Va  voltage  which  on  label  of  panel  right/top.
(Deviation; ±0.5V)
Each PCB assembly must be checked by check JIG set.
(Because power PCB Assembly damages to PDP Module,
especially be careful)
(Fig.1) Connection diagram of power adjustment for measuring
<42” EAY3292701>
- 7 -
6. EDID (The Extended Display
Identification Data)/ DDC (Display
Data Channel) download
* Caution
(1) Use the proper signal cable for EDID Download.
- Analog EDID : Pin3 exists.
- Digital EDID : Pin3 exists.
(2) Never connect HDMI & DVI-D & DVI-A Cable at the same
time.
(3) Use the proper cables below for EDID Writing.
6-1. EDID Data
6-2. Setting of device
6-3. Preparation for Adjustment
1) As above Fig. 2, Connect the Set, EDID Download Jig, PC
& Cable.
2)  Turn  on  the  PC  &  EDID  Download  Jig.  And  Execute  the
S/W : EDID TESTER Ver,2.5.
3) Set up S/W option.
Repeat Number : 5
Device Address : A0
PageByte : 8
4) Power on the Set.
6-4. Sequence of Adjustment
- EDID Download
1) Init the data.
2) Load the EDID data.(Open File).
[Analog file] (for RGB)
[Digital file]  (for HDMI)
3) Set the S/W as below.
4) Push the “Write Data & Verify”button. And confirm “Yes”.
5) If the writing is finished, you will see the “OK” message.
6)  If  TV  has  two  HDMI,  you  must  download  two  times  for
each HDMI.
(Fig. 2) Connection Diagram of DDC download
Open File
Open File
Item
Manufacturer ID
Version
Revision
Condition
GSM
Digital : 1
Digital : 3
Hex Data
1E6D
01
03
For RGB EDID
D-sub to D-sub
For HDMI EDID
DVI-D to HDMI or HDMI to HDMI
- 8 -
- EDID DATA
1) Analog RGB(128Byte).
2) HDMI1 RGB(256Byte).
=> Detail EDID Options are below(
,
,
,
,
-1,
-2,
-1,
-2)
3) HDMI1 RGB(256Byte).
=> Detail EDID Options are below(
,
,
,
,
-1,
-2,
-1,
-2)
1. 
-> Product ID
2. 
-> Serial No :  Controlled on production line
3. 
-> Month, Year : Controlled on production line
ex) Week : '03'     =>  '03' 
Year   : '2006' =>  '10'
4.
-> Model Name(Hex):
5.
-1,
-2,
-1,
-2  -> Checksum    :  Changeable  by  total
EDID data
7. ADC Calibration
Model Name
42PT85-ZB
50PT85-ZB
-1
89
8A
-2
C2
C3
-1
CC
CC
-2
F2
BC
Model
Name
42PT85
50PT85
Product ID
Product ID
EDID table
B69C
B69C
Dec
Hex
9CB6
9CB6
Model Name
42PT85-ZB
50PT85-ZB
Hex Data
000000FC003432505438350A202020202020
000000FC003530505438350A202020202020
- System control RS-232 Host should be “PC“ for adjustment.
- Before AV ADC Calibration, execute the “Panel size selection“
ADC
RF/AV/S-VIDEO
Component
RGB-PC
MSPG925FS PAL
Model:215 (720P)
Model: 60 
INPUT  SELECT     AV3
Pattern:65
(1024*768 60Hz)
Model: 202 (PAL-BGDHI) 720P/50Hz 
Pattern: 65
Pattern: 65
7 Color Bar
PAL 7 Color Bar
Page of 32