- 5 -
V
Model General Specification
(1) Central and South America (MA)
No
Item
Specification
Remark
1.
Market
Central and South America
2.
Broadcasting system
PAL/SECAM-BG/I/DK, NTSC-M
3.
Available Channel
BAND
PAL
NTSC
China(DK)
Australia(BG)
VHF/UHF
E2 ~ C69
2~78
VHF/UHF
C1~C62
C1~C75
CATV
S21 ~ S41
1~71
CATV
S1~S41
S2~S44
4.
Receiving system
Upper Heterodyne
5.
Video Input (2EA)
PAL,SECAM, NTSC
Rear 1EA, Side 1EA
6.
Component Input (2EA)
Y/Cb/Cr, Y/ Pb/Pr
7.
RGB Input (1EA)
RGB-PC 
8.
HDMI Input          2ea
HDMI-DTV , Only PCM MODE
Side HDMI(1), Rear HDMI(1) 
: 42/50PT250R-MA only
3ea
Side HDMI(1), Rear HDMI(2)
9.
Audio Input (5EA)
L/R Input(PC 1EA, Component 2EA, 
Rear 1EA, Side 1EA)
10.
RS-232C (1EA)
Remote control 
11.
USB Input (1EA)
SD DivX, MP3, JPEG,
- 6 -
ADJUSTMENT INSTRUCTION
1. Application Range
This spec sheet is applied to all of the PP11K chassis. 
2. Specification
(1) Because this is not a hot chassis, it is not necessary to use
an  isolation  transformer.  However,  the  use  of  isolation
transformer will help protect test instrument.
(2) Adjustment must be done in the correct order.
(3) The adjustment must be performed in the circumstance of
25 °C ± 5 °C of temperature and 65 % ± 10 % of relative
humidity if there is no specific designation.
(4) The  input  voltage  of  the  receiver  must  keep  100  V
~ 240 V, 50 / 60 Hz.
(5) The receiver must be operated for about 5 minutes prior to
the adjustment when module is in the circumstance of over
15 °C
- In case of keeping module is in the circumstance of 0 °C,
it  should  be  placed  in  the  circumstance  of  above  15  °C
for 2 hours
- In case of keeping module is in the circumstance of below
-20 °C, it should be placed in the circumstance of above
15 °C for 3 hours,.
3. S/W Program Download
3-1. Profile
This  is  for  downloading  the  s/w  to  the  flash  memory  of  the
IC402
3-2. Equipment 
(1) PC
(2) ISP_tool program
(3) Download jig
3-3. Connection Structure
3-4. Connection Condition
(1) IC name and circuit number : Flash Memory and IC402
(2) Use voltage : 3.3V (5 pin)
(3) SCL : 15 pin
(4) SDA : 12 pin
(5) Tact time : about 2min and 30seconds
3-5. Download Method (By using MSTAR JIG)
- Preliminary Steps
(1) Download method (PCB Ass’y)
- HD
1) Connect the download jig to D-sub jack
2) Connect the PC to USB jack
(2) Download Steps
1) Execute ‘ISP Tool’ program in PC, then a main window
will be opened
2) Click the connect button and confirm “Dialog Box”
Double click
- 7 -
3) Click the Config button and Change speed
E2PROM Device setting : over the 350Khz
4) Read and write bin file
Click  “(1)Read”  tab,  and  then  load  download
file(XXXX.bin) by clicking “Read”.
5) Click “Auto(2)” tab and set as below
6) Click “Run(3)”.
7) After downloading, check “OK(4)” message. 
3-6. Download Method (By using USB 
Memory Stick) 
* Caution
- Using ‘power on’ button of the control R/C, power on TV.
- USB  file  (EPK)  version  must  be  bigger  than  downloaded
version of main B/D.
- It should be only one SW binary file in USB Stick 
(1) Using ‘Power ON’ button of the control R/C, Power on TV.
(2) Insert the USB memory stick to the SET.
(3) Display  USB  loding  message  then,  push  the  ‘Exit’  Key  of
control R/C
(4) Push  the  ‘MENU’  Key  and  move  the  cusor  ‘OPTION’  of
OSD ( Fig. 1)
* Caution : Don’t  push  the  ‘OK’  key.Just  cusor  is  on  the
‘OPTION’ menu.
(5) Push the “7” key of control R/C continuously.
Then, Display “TV Software Update” Pop-up menu. (Fig. 2)
(6) Select SW file (XXXX.bin) you want, push the “OK” Key.
(7) S/W download process is excuted automatically.
( Fig. 1)
( Fig. 2)
- 8 -
4. PCB Assembly Adjustment Method
4-1. Option Adjustment Following BOM 
Tool Option
Area Option
Option 1
Option 2
Option 3(Available for EU & Non EU model)
* Profile: Must  be  changed  the  option  value  because  being
different with some setting value depend on module,
inch and market 
* Equipment : Adjustment Remote Controller
(1) Push the IN-START key in the Adjust R/C.
(2) Enter Password number. The value of Password is “0 0 0
0”.
(3) Input  the  Option  Number  that  was  specified  in  the  BOM,
into the Shipping area.
(4) Select  “Tool  Option”  by  using 
D
/
E
(CH+/-)  key,  and  press
the number key(0~9) consecutively
ex) If  the  value  of  Tool  Option1  is  4,  input  the  data  using
number key “4” (Fig. 3)
(5) if  it  is  EU  model  (  such  as  42/50PJ**R-ZA  ),  select  “Area
option”  by  using 
D
/
E
(CH+/-)  key  ,  and  press  the  number
key(0~9) consecutively.
ex) If  the  value  of  Area  Option  is  40,  input  the  data  using
number key “40” (Fig. 3)
Caution
- Don’t  Push  “IN-STOP”  key  after  PCB  assembly
adjustment.
* PP01A/B/C Tool option
(6) EDID D/L Method
- After  software  D/L  or  PCBA  manufacturing,  you  can
download EDID Data.
- When you adjust Tool Option, H6 Model EDID download
process is executed automatically
* If the model don’t have HDMI 3, HDMI 3 will be disappeared
at OSD Window.
[Caution]
- When  you  adjust  tool  option,  don’t  connect  HDMI  or  D-
sub cable. 
- If  you  connect  some  cable,  EDID  D/L  process  will  be
failed. 
(7) Adjustment method    
Before  PCBA  check,  have  to  change  the  Tool  option  and
Area option  
[ About PDP
After  done  all  adjustments,  Press  IN-START  button  and
compare Tool option and Area option value with its BOM, if
it  is  correctly  same  then  Change  “RF  mode”  and  then
unplug the AC cable.
If it is not same, then correct it same with BOM and unplug
AC cable. 
For  correct  it  to  the  model’s  module  from  factory  JIG
model.
[ Don’t push The IN-STOP KEY after completing the function
inspection.
5. EDID(The Extended Display
Identification Data)  
Caution 
- Never    Use  the  cable(  HDMI  or  D-sub  cable)  for  EDID
Writing. 
- Automatically PP01A/B/C Model EDID download process
is executed when you adjust Tool Option.
( Fig. 3)
Model
Tool option
Area Option
42PT250R-TA
13
1
Inch
Tool
SIDE AV
0/1
HDMI
0/1/2/3
Side HDMI
0/1
COMP2
0/1
RGB
0/1
RS232C
0/1
Local Key
0 (7KEY) / 1 (8KEY)
LED TYPE
0 (RED) / 1 (RED/White) / 2 (Reserve)
USB TYPE
0 (NONE) / 1 (PHOTO, MUSIC) 
/ 2 (PHOTO, MUSIC, DivX)
Page of 33