O
HDMI-2 EDID table(Full HD)
O
HDMI-3 EDID table(HD)
O
HDMI-3 EDID table(Full HD)
O
Analog (RGB) EDID table(HD)
O
Analog (RGB) EDID table(Full HD)
See Working Guide if you want more information about EDID
communication.
- 13 -
7. Adjustment Color Temperature  
(White balance)
7-1. Using Instruments
(1) Color Analyzer: CA-210 (CH 9)
- Using LCD color temperature, Color Analyzer (CA-210)
must use CH 9, which Matrix compensated (White, Red,
Green, Blue compensation) with CS-2100. See the
Coordination bellowed one. 
(2) Auto-adjustment Equipment (It needs when Auto-
adjustment - It is availed communicate with RS-232C :
Baud rate: 115200) 
(3) Video Signal Generator MSPG-925F 720p, 216Gray
(Model: 217, Pattern 78)
7-2. Connection Diagram (Auto Adjustment)
(1) Using Inner Pattern
(2) Using HDMI input
7-3. White Balance Adjustment 
If you can’t adjust with inner pattern, then you can adjust it
using HDMI pattern. You can select option at “Ez-Adjust Menu
- 7. White Balance” there items “NONE, INNER, HDMI”. It is
normally setting at inner basically. If you can’t adjust using
inner pattern you can select HDMI item, and you can adjust.
In manual Adjust case, if you press ADJ button of service
remocon, and enter “Ez-Adjust Menu - 7. White Balance”,
then automatically inner pattern operates. (In case of “Inner”
originally “Test-Pattern. On” will be selected in The “Test-
Pattern. On/Off”. 
(1) Connect all cables and equipments like (Fig. 1)
(2) Set Baud Rate of RS-232C to 115200. It may set 115200
orignally.
(3) Connect RS-232C cable to set
(4) Connect HDMI cable to set
O
RS-232C Command (Commonly apply) 
- “wb 00 00”: Start Auto-adjustment of white balance.
- “wb 00 10”: Start Gain Adjustment (Inner pattern) 
- “jb 00 c0” : 
-  ...
- “wb 00 1f”: End of Adjustment
- If it needs, offset adjustment (wb 00 20-start, wb 00 2f-end)
- “wb 00 ff”: End of white balance adjustment (inner pattern
disappear)
Notice) Adjustment Mapping information
O
When Color temperature (White balance) Adjustment
(Automatically)
- Press “Power only key” of service remocon and operate
automatically adjustment.
- Set BaudRate to 115200.
O
You must start “wb 00 00” and finish it “wb 00 ff”.
O
If it needs, then adjustment “Offset”.
- 14 -
 
(Fig. 1) Connection Diagram for Adjustment White balance
7-4. White Balance Adjustment (Manual
Adjustment)
(1) Test Equipment: CA-210
Using PDP color temperature, Color Analyzer (CA-210)
must use CH 10, which Matrix compensated (White, Red,
Green, Blue compensation) with CS-2100. See the
Coordination bellowed one. 
(2) Manual adjustment sequence is like bellowed one.
1) Turn to “Ez-Adjust” mode with press ADJ button of
service remocon.
2) Select “10.Test Pattern” with CH+/- button and press
enter. Then set will go on Heat-run mode. Over 30
minutes set let on Heat-run mode.
3) Let CA-210 to zero calibration and must has gap more
10cm from center of PDP module when adjustment. 
4) Press “ADJ” button of service remocon and select
“7.White-Balance” in “Ez-Adjust” then press “
G
” button
of navigation key.
(When press “
G
” button then set will go to full white
mode)
5) Adjust at three mode (Cool, Medium, Warm)
6) If “cool” mode 
Let B-Gain to 192 and R, G, B-Cut to 64 and then
control R, G gain adjustment High Light adjustment.
7) If “Medium” and “Warm” mode Let R-Gain to 192 and R,
G, B-Cut to 64 and then control G, B gain adjustment
High Light adjustment.
8) All of the three mode 
Let R-Gain to 192 and R, G, B-Cut to 64 and then
control G, B gain adjustment High Light adjustment.
9) With volume button (+/-) you can adjust.
10) After all adjustment finished, with Enter (
V
key) turn to
Ez-Adjust mode. Then with ADJ button, exit from
adjustment mode
O
White Balance adjustment coordination and color temperature.
(1) Using CS-1000 Equipment. 
- COOL : T=11000K, 
uv=0.000, x=0.276 y=0.283 
- MEDIUM  : T=9300K, 
uv=0.000, x=0.285 y=0.293 
- WARM  : T=6500K, 
uv=0.000, x=0.313 y=0.329 
(2) Using CA-210 Equipment. (10 CH) 
Contrast value: 216 Gray 
O
Brightness Spec.
8. Test of RS-232C Control
Press In-Start button of Service Remocon then set the
“4.Baud Rate” to 115200. Then check RS-232C control and 
9. Selection of Country Option
(1) Models: All models which PB91A/PB92A Chassis. 
(2) Press “In-Start” button of Service Remocon, then enter
the “Option” Menu with “PIP CH-” Button 
(3) Select one of these three (USA, CANADA, MEXICO)
defends on its market using “Vol. +/-” button.
[
Caution : Don’t push The INSTOP KEY after completing the
function inspection.
10. GND and ESD Testing
10-1. Prepare GND and ESD Testing
Check the connection between set and power cord
10-2. Operate GND and ESD auto-test
(1) Fully connected (Between set and power cord) set enter
the Auto-test sequence.
(2) Connect D-Jack AV jack test equipment.
(3) Turn on Auto-controller(GWS103-4)
(4) Start Auto GND test.
(5) If its result is NG, then notice with buzzer.
(6) If its result is OK, then automatically it turns to ESD Test.
(7) Operate ESD test
(8) If its result is NG, then notice with buzzer.
(9) If its result is OK, then process next steps. Notice it with
Good lamp and STOPER Down.
- 15 -
 
10-3. Check Items
(1) Test Voltage 
- GND: 1.5KV/min at 100mA
- Signal: 3KV/min at 100mA
(2) Test time: just 1 second.
(3) Test point
- GND test: Test between Power cord GND and Signal
cable metal GND.
- ESD test: Test between Power cord GND and Live and
neutral.
(4) Leakage current: Set to 0.5mA(rms)
10-4. POWER PCB Assy Voltage Adjustment 
(Va, Vs voltage adjustment) <— ONLY PDP
(1) Profile
To supply the Va, Vs voltage that the module want.
(2) Equipment :
Stick for adjustment, DMM
(3) 42Inch/50Inch Adjustment method for Power board
- After Changing RF snow noise.
1) Connection Diagram for measuring
2) Vs Adjustment 
Connect + terminal of D. M..M. to Vs pin of P811,
connect - terminal to GND pin of P811.
After turning VR901, voltage of D.M.M adjustment as
same as Vs voltage which on label of panel right/top  (
deviation ; ±0.5V)
(4) 50FHD Adjustment method for Power board
- After Changing RF snow noise.
1) Connection Diagram for measuring
2) Va Adjustment 
Connect + terminal of D. M..M. to Va pin of P811,
connect - terminal to GND pin of P811.
After turning VR501, voltage of D.M.M adjustment as
same as Va voltage which on label of panel right/top  (
deviation ; ±0.5V)
3) Vs Adjustment 
Connect + terminal of D. M..M. to Vs pin of P811,
connect - terminal to GND pin of P811.
After turning VR901, voltage of D.M.M adjustment as
same as Vs voltage which on label of panel right/top  (
deviation ; ±0.5V)
(5) 60FHD Adjustment method for Power board
- After Changing RF snow noise.
1) Connection Diagram for measuring
2) Va Adjustment 
Connect + terminal of D. M..M. to Va pin of P812,
connect - terminal to GND pin of P812.
After turning VR901, voltage of D.M.M adjustment as
same as Va voltage which on label of panel right/top  (
deviation ; ±0.5V)
3) Vs Adjustment 
Connect + terminal of D. M..M. to Vs pin of P812,
connect - terminal to GND pin of P812.
After turning VR951, voltage of D.M.M adjustment as
same as Vs voltage which on label of panel right/top  (
deviation ; ±0.5V)
- 16 -
Connection Diagram of power adjustment for measuring.
Connection Diagram of power adjustment for measuring.
Connection Diagram of power adjustment for measuring.
Page of 65