* Equipment : Adjustment Remote Controller
(1) Push the IN-START key in the Adjust R/C.
(2) Enter Password number. The value of Password is “0 0 0
(1) Push the IN-START key in the Adjust R/C.
(2) Enter Password number. The value of Password is “0 0 0
0”.
(3) Input the Option Number that was specified in the BOM,
into the Shipping area.
(4) Select “Tool Option/ Area Option” by using
D
/
E
(CH+/-) key,
and press the number key(0~9) consecutively
ex) If the value of Tool Option1 is 4, input the data using
ex) If the value of Tool Option1 is 4, input the data using
number key “4” (Fig. 3)
Caution: Don’t Push “IN-STOP” key after PCB assembly
adjustment.
9. Adjustment of White Balance
9-1. Purpose and Principle for Adjustment
of the Color Temperature
(1) Purpose: Adjust the color temperature to reduce the
deviation of the module color temperature.
(2) Principle : To adjust the white balance without the
saturation, Fix the one of R/G/B gain to C0 and decrease
the others.
the others.
(3) Adjustment mode: Two modes of Cool, Warm and Medium
9-2. Required Equipment
(1) Remote controller for adjustment
(2) Color Analyzer : CA-100+ or CA-210 or same product
(2) Color Analyzer : CA-100+ or CA-210 or same product
- PLASMA TV(ch : 10)
(3) Auto W/B adjustment instrument(only for Auto adjustment)
- Do the white balance adjustment under the 10LUX
* Notice: When using the Color Analyzer with PDP,
recommend the CA-100 more than CA-210.
If CA-100 can not available, it is also good to use the CA-210.
If CA-100 can not available, it is also good to use the CA-210.
(4) PC (for communication through RGB)
(5) Pattern Generator (MSPG-925FA etc.)
(5) Pattern Generator (MSPG-925FA etc.)
-Before white balance, press the ADJ key and select third
row like (Fig. 5)
-To enter White-balance mode, Enter Password Number “0
0 0 0” and select third row.
* Caution: System control Host should be “DDC” for adjustment.
(6) Adjust W/B DATA, for all CSM, choose ‘COPY ALL’
9-3. Connecting Diagram of Equipment for
Measuring
(For Automatic Adjustment)
(Method 2, using RS-232C, You connect RS-232C Cable)
(1) Enter the adjustment mode of the white balance
- Enter the white balance adjustment mode at the same time
heat-run mode when pushing the power on by power only
key
key
- Maintain the white balance adjustment mode with same
condition of Heat-run
- Maintain after AC off/on in status of Heat-run pattern display
(2) Release the white balance adjustment mode
- Release the adjust mode after AC off/on or std-by off/on in
status of finishing the Hear-run mode
- Release the Adjust mode when receiving the aging off
command(F3 00 00) from adjustment equipment)
(3) Enter the adjust mode of white balance
- Enter the white balance adjustment mode with aging
command(F3, 00, FF)
- 13 -
EZ ADJUST
0. ADC CALIBRATION : TV
1. ADC ADJUST
2. SUB B/C ADJUST
2. SUB B/C ADJUST
3. W/B ADJUST
4. WHITE PATTERN : OFF
5. EDID D/L
5. EDID D/L
(Fig. 5)
3. W/B ADJUST
ModeZZZ
: TV
TEMPERATUREZZ
: Medium
R-Gain.ZZZ
: 192
G-Gain.ZZZ
: 192
B-Gain.ZZZ
: 192
R-OffsetZZZ
: 128
G-OffsetZZZ
: 128
B-OffsetZZZ
: 128
COPY ALL
(Fig. 6)
Method 2-(RS-232C)
9-4. Adjustment of White Balance for
Manual Adjustment
(method 3)
Adjustment mode: Three modes of Cool, Medium(Vivid) and
Warm
Warm
- Equipment
1) Color analyzer(CA100+, CA210) should be used in the
calibrated ch by CS-1000(PDP : CH10)
2) Adjustment remocon
- For manual adjustment, it is also possible by the following
sequence.
Operate the zero-calibration of the CA-100+ or CA-210, then
stick sensor to the module when adjusting.
Operate the zero-calibration of the CA-100+ or CA-210, then
stick sensor to the module when adjusting.
(1) Select white pattern of heat-run by pressing “POWER ON”
key on remote control for adjustment then operate heat run
longer than 5 minutes. (recommend)
(If not executed this step, the condition for W/B will be
different)
longer than 5 minutes. (recommend)
(If not executed this step, the condition for W/B will be
different)
(2) Changing to the AV mode by remote control.(Push front-
AV)
(3) Input external pattern(85% white pattern).
(4) Stick sensor to center of the screen and select each items
(4) Stick sensor to center of the screen and select each items
(Red/Green/Blue Gain and Offset) using
D
/
E
(CH +/-) key on
R/C..
(5) Adjust R/ G/ B Gain using
F
/
G
(VOL +/-) key on R/C.
(6) Adjust three modes of Cool, Medium(Vivid) and Warm as
below figure.
(Fix the one of R/G/B and change the others)
- Push the “VOL + “ key : Cool, Medium, Warm
(Fix the one of R/G/B and change the others)
- Push the “VOL + “ key : Cool, Medium, Warm
* Refer to the below case to know what value is fixed.
[CASE]
First adjust the coordinate much away from the target value(x, y).
First adjust the coordinate much away from the target value(x, y).
1. x, y > target
1) Decrease the R, G.
2. x, y < target
1) First decrease the B gain,
2) Decrease the one of the others.
2) Decrease the one of the others.
- In case of decreasing the x, decreasing the R : fix G
- In case of decreasing the y , decreasing the G : fix R
- In case of decreasing the y , decreasing the G : fix R
3. x > target , y < target
1) First decrease B, so make y a little more than the target.
2) Adjust x value by decreasing the R
2) Adjust x value by decreasing the R
4. x < target , y > target
1) First decrease B, so make x a little more than the target.
2) Adjust x value by decreasing the G
2) Adjust x value by decreasing the G
(7) When adjustment is completed, Exit adjustment mode
using EXIT key on R/C.
9-5. Connecting diagram of Equipment for
Measuring
(For Automatic Adjustment)
(method 1, using IIC, You connect RGB Cable)
(1) Enter the adjustment mode of the white balance
- Enter the white balance adjustment mode at the same time
heat-run mode when pushing the power on by power only
key
key
- Maintain the white balance adjustment mode with same
condition of Heat-run
- Maintain after AC off/on in status of Heat-run pattern display
(2) Release the white balance adjustment mode
- Release the adjust mode after AC off/on or std-by off/on in
status of finishing the Hear-run mode
- push the “power on” key(IIC Mode) on Adjust remote-
controller.
- Release the Adjust mode when receiving the aging off
command(F3 00 00) from adjustment equipment)
(3) Enter the adjust mode of white balance
- Enter the white balance adjustment mode with aging
command(F3, 00, FF)
O
Color Temperature & Color Coordinates Setting
- When adjusting the Color Temperature, Color Analyzer CA-
210(Matrix should be corrected through CH10 of CS-1000)
should be used. When CA-210 have used, it don’t need to fit
the CH10.
should be used. When CA-210 have used, it don’t need to fit
the CH10.
- Adjust the Color Temperature based below adjustment color
coordinates.
O
Target Value CA-210(LCD : CH 9, PDP : CH10), CA-100(PDP)
(Standard color coordinate and temperature when using the
CA-100+ or CA210 equipment)
O
Above optical characteristics are should be measured by
following condition
- 14 -
+0.003
6,500K
Warm
+0.000
9,300K
Medium
+0.000
11,000K
Cool
0.276±0.002
0.285±0.002
0.293±0.002
0.329±0.002
0.313±0.002
0.283±0.002
Y
X
uv
Temp
Color coordinate
Mode
Method 1-(I
2
C)
+0.003
6,500K
Warm
+0.000
9,300K
Medium
+0.000
11,000K
Cool
0.276±0.002
0.285±0.002
0.293±0.002
0.329±0.002
0.313±0.002
0.283±0.002
Y
X
uv
Temp
Color coordinate
Mode
- 15 -
O
DDC Adjustment Command Set
[ R/G/B GAIN max value : C0
Adjustment
Adjustment
Adjustment
- 16 -
BLOCK DIAGRAM