- 13 -
8-4. Manual White Balance 
(1)  Press  the  POWER  ON  KEY  on  R/C  for  adjustment  and
heat run over 5 minutes.
(2)  Zero  Calibrate  CA-100+  /  CA-210,  and  when  controlling,
stick the sensor to the center of PDP module surface.
(3) Press the ADJ KEY on R/C and enter EZ ASJUST
Select “3.W/B ADJUST” and press ENTER(
V
)
Set test-pattern on and display inside pattern. 
(4) Control is carried out on three color temperatures, COOL,
MEDIUM, WARM.(Control is carried out three times)
<Temperature: COOL>
- R-offset / G-offset / B-offset is set to 128
- Control R-Gain and G-Gain.
- Each gain is limited to 192
<Temperature: MEDIUM>
- R-offset / G-offset / B-offset is set to 128
- Control R-Gain and G-Gain.
- Each gain is limited to 192
<Temperature: WARM>
- R-offset / G-offset / B-offset is set to 128
- Control G-Gain and B-Gain.
- Each gain is limited to 192
9. HDCP SETTING
(Not necessary) 
Caution: Key is saved in external eeprom. 
10. RS-232C 
Press  In-start  key  and  select  4.Baud  Rate  menu.  Check  RS-
232C after changing Baud Rate 115200.
11. TOOL OPTION
11-1. Using DFT(Auto)
PC  (for  communication  through  RS-232C)  ==>  UART  Baud
rate : 115200 bps
Command : ab 00 00 DATA(Model Number(hexadecimal))
11-2. Setting Manual
Press  ADJ  R/C  In-start  key  and  select  0.TOOL  OPTION,
Select Model Number by using R/C number(0~9) key or select
Model  Number  by  using 
F
/
G
(VOL  +/-)  in  accordance  with
destination.
Finally press 
9
(enter) key.
12. AREA OPTION
12-1. Using DFT(Auto)
PC  (for  communication  through  RS-232C)  ==>  UART  Baud
rate : 115200 bps
Command : ah 00 00 DATA(Area Number(hexadecimal))
12-2. Setting Manual
Press  ADJ  R/C  In-start  key  and  select  1.AREA  OPTION,
Select  Model  Number  by  using 
F
/
G
(VOL  +/-)  in  accordance
with destination
ITEM
DATA(Model Number)
M
0
42PQ20
1
50PQ20
2
42PQ30/42PQ31
3
50PQ30/50PQ31
4
42PQ60
5
50PQ60
TOOL OPTION1
6
50PS30
7
50PS60
8
60PS60
9
60PS11
A
42PQ10
B
50PQ10
1E
50PS11
- 14 -
TROUBLE SHOOTING GUIDE
- 15 -
- 16 -
Page of 53
Display