- 5 -
V
Model General Specification
 
 
 
 
 
 
 
 
 
 
- 6 -
ADJUSTMENT INSTRUCTION
1. Application
This spec. sheet is applied to all of the PD91A chassis.
2. Specification
[Caution: The module keeping condition]
1.  The  module  keeping  condition:  The  normal  temperature
condition(more than 15°C)
--> Immediately the line supply.
2. The module keeping condition: 0°C
-->  The module must be kept for more than 2 hours at the
normal temperature.
3. The module keeping condition: -20°C
-->  The module must be kept for more than 3 hours at the
normal temperature.
4. The case of Gu-mi factory at the winter season.
-->    The  module  must  be  kept  for  more  than  5  minutes  at
the heating zone(40°C~45°C).
(1)  The  adjustment  is  according  to  the  order  which  is
designated  and  which  must  be  followed,  according  to  the
plan which can be changed only on agreeing.
(2) If there is no specific designation, the adjustment must be
performed  in  the  circumstance  of  25±5°C  of  temperature
and 65±10% of relative humidity.
(3)  The  input  voltage  of  the  set  must  keep  100~240V,
50/60Hz.
(4) Input signal Unit: Product Specification Standard.
(5) The set must be operated for about 5 minutes prior to the
adjustment.
O
After  turning  on  RGB  Full  Window  pattern  in  HEAT-RUN
Mode, the receiver must be operated.
O
Enter into HEAT-RUN MODE 
1) Press the ‘POWER ON’ button on R/C for adjustment.
2) Press the ‘ADJ’ button on R/C and enter EZ ADJUST
Select “7. Test Pattern” by using 
D
/
E
(CH +/-) and press
ENTER(
V
)
Select  “White”  by  using 
F
/
G
(VOL  +/-)  and  press
ENTER(
V
)
- Set heat run should be activated without a signal generator. 
- Single color patterns (RED / BLUE / GREEN) of HEAT RUN
MODE are used to check a plasma panel. 
-  Caution:  If  you  turn  on  a  still  screen  more  than  20  minutes
(Especially  digital  pattern,  cross  hatch  pattern),  an  after
image may be made in the black level part of the screen.
[Caution] 
- Use ‘power on’ button of a service R/C to power on TV set.
-  Do  not  connect  any  external  input  cable  if  there  is  no  any
specifics.
3. Update S/W using Auto Download
through the USB
Caution:  S/W  version  of  USB  file  (xxx.epk)  must  be  bigger  than
one which is downloaded previously.
(1) Insert the USB stick to the USB socket 
(2)  A  downloaded  file  in  USB  stick  will  be  detected
automatically.
(3)  If  S/W  version  of  USB  file  (xxx.epk)  is  bigger  than  one
which  is  downloaded  previously,  the  message,  “Copying
files from memory”, will appear. 
(4)  If  an  update  procedure  was  completed,  TV  set  will  be
turned off and on automatically.
(5) If TV set is turned on, check an updated version.
* If a downloaded version is more bigger than one of which
TV  set  had,  TV  set  can  lost  channel  data.  In  this  case,
you have to scan channels again. 
4. After Downloading S/W, Adjust 
TOOL OPTION
(1) Push “IN-START” button on a service R/C.
(2) Select “Tool Option 1” and Push “OK” button.
(3) Put the number of a below table in order of a suffix of the
“Tool Option(X)”. 
(Each model has a different number.)
5. ADC Calibration Procedure
(1) Input the component (480i/Horizontal Color Bar) signal to a
TV set.
1) Input Signal Timing : Component 480i 
(Other  external  connection  is  unnecessary  except  the
component before executing ADC calibration.)
2) Input Signal Pattern
@ MODEL: 209 in Pattern Generator(480i Mode)
@  PATTERN  :  65  in  Pattern  Generator(MSPG-925
SERISE) 
(2) Push “ADJ” button on a service R/C.
(3) Enter internal ADC mode by selecting ‘5. ADC Calibration’.
(4)  If  you  select  ‘Start’  on  a  dialog  box  of  the  screen,  ADC
calibration will be begun.
Caution:  Don’t  connect  any  external  input  cable  except  the
component  input(480i/Horizontal_Color_Bar)  to  adjust
ADC calibration
O
Auto ADC Calibration Map(RS-232C)
# Adjust Sequence
- aa 00 00  [Enter Adjust Mode]
- xb 00 40  [Component1 Input (480i)]
- ad 00 10  [Adjust 480i Comp1]
- xb 00 60  [RGB Input (1024*768)]
- ad 00 10  [Adjust 1024*768 RGB]
- aa 00 90  End Adjust mode
6. EDID Download Procedure
(1) Push “ADJ” button on a service R/C.
(2)  Enter  EDID  auto  download  mode  by  selecting  ‘8.  EDID
D/L’.
(3)  If  you  select  ‘Start’  on  a  dialog  box  of  the  screen,  EDID
download will be begun automatically.
(4) Press ‘EXIT’ button on a service R/C.
(5) EDID Data
1) HDMI (256 bytes)
2) RGB (128 bytes)
O
EDID Data detailing (
ⓐ, ⓑ, ⓒ, ⓓ, ⓔ, ⓕ)
- 7 -
<Horizontal Color Bar pattern>
NO
Item
CMD1
A
A
0
0
0
1
D
A
CMD2 Data0
Enter  
Adjust MODE
Adjust 
‘Mode In’
When transfer the ‘Made
In’, Carry the command.
Automatically adjustment
(The use of a internal
pattern)
ADC
Adjust
ADC Adjust
ⓐ Product ID 
ⓑ Serial No
=> Controlled on production line
ⓒ Month, Year
=> Controlled on production line:  
ⓓ Model Name
ⓔ Checksum
=> Changeable by total EDID data
ⓕ HDMI Port No.
O
Auto EDID Download Map(RS-232C)
7. PCMCIA CARD Check
You must adjust DTV 29 Channel and insert PCMCIA CARD
to socket.
- If PCMCIA CARD works normally, video signals will appear
on screen.
But  it  works  abnormally,  “No  CA  module”  will  appear  on
screen.
[ Caution: Set up “RF mode” before launching products.
8. POWER Supply Unit PCB Ass’y 
Va/Vs Voltage Adjustment
Caution: Both Vs and Va voltage adjustment are necessary.
8-1. Model name:
50PS7000-ZA, 60PS7000-ZA, 50PS8000-ZA, 60PS8000-ZA
8-2. Va/Vs Adjustment Procedure
(1) Connect positive(+) terminal of DMM to Vs/Va pin, connect
negative(-) terminal to GND.
(2)  Turning  ‘Vs/Va  Adjust’  and  adjust  Vs/Va  voltages  to  a
value  which  is  written  on  a  right/top  label  of  a  module.
(deviation ; ±0.5V)
[Caution]
- Each Power Supply Unit PCB assembly must be checked by
check JIG set. (Because power PCB Ass’y damages to PDP
Module, especially be careful)
- Set up “RF mode(noise)” before a voltage adjustment.
- Test equipment: DMM 1EA
9. White Balance Adjustment
Caution:  Press  the  POWER  ON  KEY  on  R/C  before  W/B
adjustment.
O
Test Equipment
Color Analyzer (CS-1000, CA-100+(CH.10), CA-210(CH.10))
O
Please  adjust  CA-100+  /  CA-210  by  CS-1000  before
measuring
You  should  use  Channel  10  which  is  Matrix  compensated
(White, Red, Green, Blue revised) by CS-1000 and adjust
in accordance with White balance adjustment coordinate.
9-1. Color Temperature Standards According
to CSM and Module
- 8 -
NO
Item
CMD1
A
A
0
0
10
00
E
A
CMD2 Data0
Enter  
download
MODE
Download
‘Mode In’
When transfer the ‘Made
In’, Carry the command.
Automatically download
(The use of a internal
Data)
Download
EDID data and
Model option
download
6500K
Warm
9300K
Medium
11000K
Cool
PLASMA
CSM
Page of 44