LG 50PK750-ZA / 50PK750N-ZA (CHASSIS:PD01A) Service Manual ▷ View online

PLASMA TV
SERVICE MANUAL
CAUTION
BEFORE SERVICING THE CHASSIS,
READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
CHASSIS : PD01A
MODEL : 50PK750
50PK750-ZA
MODEL :
50PK750N
50PK750N-ZA
P/NO : MFL62881208(1003-REV00)
- 2 -
CONTENTS
CONTENTS ............................................................................................................................... 2
SAFETY PRECAUTIONS ...........................................................................................................3
SPECIFICATION.........................................................................................................................4
ADJUSTMENT INSTRUCTION ..................................................................................................7
TROUBLESHOOTING GUIDE .................................................................................................12
BLOCK DIAGRAM ...................................................................................................................23
EXPLODED VIEW  ...................................................................................................................24
SVC. SHEET  ................................................................................................................................
- 3 -
SAFETY PRECAUTIONS
Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by      in the
Schematic Diagram and Exploded View. 
It is essential that these special safety parts should be replaced with the same components as recommended in this manual to prevent
X-RADIATION, Shock, Fire, or other Hazards. 
Do not modify the original design without permission of manufacturer.
General Guidance
An  isolation  Transformer  should  always  be  used during  the
servicing  of  a  receiver  whose  chassis  is  not  isolated  from  the  AC
power  line.  Use  a  transformer  of  adequate  power  rating  as  this
protects  the  technician  from  accidents  resulting  in  personal  injury
from electrical shocks.
It  will  also  protect  the  receiver  and  it's  components  from  being
damaged  by  accidental  shorts  of  the  circuitry  that  may  be
inadvertently introduced during the service operation.
If any fuse (or Fusible Resistor) in this monitor is blown, replace it
with the specified.
When replacing a high wattage resistor (Oxide Metal Film Resistor,
over 1W), keep the resistor 10mm away from PCB.
Keep wires away from high voltage or high temperature parts.
Due  to  high  vacuum  and  large  surface  area  of  picture  tube,
extreme care should be used in handling the Picture Tube.
Do not lift the Picture tube by it's Neck.
Leakage Current Cold Check(Antenna Cold Check)
With the instrument AC plug removed from AC source, connect an
electrical  jumper  across  the  two  AC  plug  prongs.  Place  the  AC
switch in the on position, connect one lead of ohm-meter to the AC
plug prongs tied together and touch other ohm-meter lead in turn to
each  exposed  metallic  parts  such  as  antenna  terminals,  phone
jacks, etc. 
If  the  exposed  metallic  part  has  a  return  path  to  the  chassis,  the
measured resistance should be between 1MΩ and 5.2MΩ. 
When  the  exposed  metal  has  no  return  path  to  the  chassis  the
reading must be infinite.
An  other  abnormality  exists  that  must  be  corrected  before  the
receiver is returned to the customer.
Leakage Current Hot Check 
(See below Figure) 
Plug the AC cord directly into the AC outlet.
Do not use a line Isolation Transformer during this check. 
Connect  1.5K/10watt  resistor  in  parallel  with  a  0.15uF  capacitor
between  a  known  good  earth  ground  (Water  Pipe,  Conduit,  etc.)
and the exposed metallic parts.
Measure  the  AC  voltage  across  the  resistor  using  AC  voltmeter
with 1000 ohms/volt or more sensitivity.
Reverse plug the AC cord into the AC outlet and repeat AC voltage
measurements  for  each  exposed  metallic  part.  Any  voltage
measured must not exceed 0.75 volt RMS which is corresponds to
0.5mA.
In  case  any  measurement  is  out  of  the  limits  specified,  there  is
possibility  of  shock  hazard  and  the  set  must  be  checked  and
repaired before it is returned to the customer.
Leakage Current Hot Check circuit
1.5 Kohm/10W
To Instrument's
exposed 
METALLIC PARTS
Good Earth Ground
such as WATER PIPE,
CONDUIT etc.
AC Volt-meter
IMPORTANT SAFETY NOTICE
0.15uF
- 4 -
SPECIFICATION
NOTE : Specifications and others are subject to change without notice for improvement.
V
Application Range
This spec is applied to PDP TV used PD01A  Chassis.
Specification
Each part is tested as below without special appointment.
(1) Temperature : 25 °C ± 5 °C (77 °F ± 9 °F), CST : 40 ± 5
(2) Relative Humidity: 65 % ± 10 %
(3) Power Voltage: Standard Input voltage (100 V - 240 V ~, 50 / 60 Hz)
* Standard Voltage of each product is marked by models.
(4) Specification  and  performance  of  each  parts  are  followed  each  drawing  and  specification  by  part  number  in  accordance  with
SBOM.
(5) The receiver must be operated for about 20 minutes prior to the adjustment.
V
Test Method
(1) Performance : LGE TV test method followed.
(2) Demanded other specification 
Safety : CE, IEC specification
EMC : CE, IEC
V
Module Specification
(1) 50” FHD
No
Item
Specification
Remark
1
Display Screen Device
127 cm (50 inch) wide Color Display Module
PDP
2
Aspect Ratio
16:9
3
PDP Module
PDP50R1####, 
RGB Closed (Well) Type, Glass Filter (38%)
Pixel Format: 1920 horiz By 1080 ver
4
Operating Environment
1) Temp.   : 0 deg ~ 40 deg
2) Humidity : 20 % ~ 80%
5
Storage Environment
3) Temp.   : -20 deg ~ 60 deg
LGE SPEC
4) Humidity : 10 % ~ 90 %
6
Input Voltage
AC 100 V ~ 240 V, 50 / 60 Hz
Maker LG
Model Name
50PK750(N)-ZA
Brand
LG
Market
Albania, Austria, Belgium, Bosnia, Bulgaria, Coratia, Czech, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy,
Kazakhstan, Latvia, Lithuania, Luxembourg, Morocco, Netherlands, Norway,
Poland, Portugal, Romania, Russia, Serbia, Slovakia, Slovenia, Spain,
Sweden, Switzerland, Turkey, Ukraine, UK
Model Name
50PK750(N)-ZA
Brand
Safety : IEC/EN60065
EMI : EN55013
EMS : EN55020
Market
Albania, Austria, Belgium, Bosnia, Bulgaria, Coratia, Czech, Denmark,
Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy,
Kazakhstan, Latvia, Lithuania, Luxembourg, Morocco, Netherlands,
Norway, Poland, Portugal, Romania, Russia, Serbia, Slovakia,
Slovenia, Spain, Sweden, Switzerland, Turkey, Ukraine, UK
Page of 35
Display

LG 50PK750-ZA / 50PK750N-ZA (CHASSIS:PD01A) Service Manual ▷ Download

  • DOWNLOAD LG 50PK750-ZA / 50PK750N-ZA (CHASSIS:PD01A) Service Manual ↓ Size: 16 MB | Pages: 35 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG 50PK750-ZA / 50PK750N-ZA (CHASSIS:PD01A) in PDF for free, which will help you to disassemble, recover, fix and repair LG 50PK750-ZA / 50PK750N-ZA (CHASSIS:PD01A) Plasma. Information contained in LG 50PK750-ZA / 50PK750N-ZA (CHASSIS:PD01A) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.