LG 50PK550C-UD (CHASSIS:PU01A) Service Manual ▷ View online
- 9 -
ADJUSTMENT INSTRUCTION
1. Application Range
This spec sheet is applied to all of the PU01A Chassis.
2. Specification
1) Because this is not a hot chassis, it is not necessary to use
an isolation transformer. However, the use of isolation
transformer will help protect test instrument.
transformer will help protect test instrument.
(2) Adjustment must be done in the correct order.
(3) The adjustment must be performed in the circumstance of
(3) The adjustment must be performed in the circumstance of
25
c
C ± 5 cC of temperature and 65 % ± 10 % of relative
humidity if there is no specific designation.
(4) The input voltage of the receiver must keep
100 V ~ 240 V, 50 / 60 Hz.
(5) The receiver must be operated for about 5 minutes prior to
the adjustment when module is in the circumstance of over
15 cC
15 cC
- In case of keeping module is in the circumstance of 0 cC,
it should be placed in the circumstance of above 15 cC for
2 hours
2 hours
- In case of keeping module is in the circumstance of below
-20 cC, it should be placed in the circumstance of above
15 cC for 3 hours.
15 cC for 3 hours.
1) Press the POWER ON KEY on R/C for adjustment.
2) Press the ADJ KEY on R/C and enter EZ ADJUST.
2) Press the ADJ KEY on R/C and enter EZ ADJUST.
Select “4. WHITE PATTERN” by using
D
/
E
(CH +/-) and
select “White” by using
F
/
G
(VOL +/-)
- Set is activated HEAT run without signal generator in this
mode.
- Single color pattern (RED / BLUE / GREEN) of HEAT
RUN MODE uses to check panel.
Caution: If you turn on a still screen more than 20 minutes
(Especially digital pattern, cross hatch pattern), an after
image may be occur in the black level part of the
screen.
image may be occur in the black level part of the
screen.
3. PCB assembly adjustment method
* Caution: Set up “RF mode(noise)” after PCB assembly
adjustment.
*Download
(1) Execute ISP program “Mstar ISP Utility” and then click
(1) Execute ISP program “Mstar ISP Utility” and then click
“Config” tab.
(2) Set as below, and then click “Auto Detect” and check “OK”
message
If display “Error”, Check connect computer, jig, and set.
(3) Click “Connect” tab. If display “Can’t ”, Check connect
computer, jig, and set.
(4) Click “Read” tab, and then load download file(XXXX.bin)
by clicking “Read”
(5) Click “Auto” tab and set as below
(6) Click “Run”.
(7) After downloading, check “OK” message.
(6) Click “Run”.
(7) After downloading, check “OK” message.
(1)
(3)
(2)
OK
vr
Please Check the Speed :
To use speed between from 200KHz to 400KHz
(4)
filexxx.bin
(5)
(6)
(7) ÉÉÉ.OK
4. ADC Process
4-1. Auto ADC Process (using DFT)
PC (for communication through RS-232C) UART Baud rate
: 115200 bps
Command : aa 00 00 (Start factory mode)
Command : ad 00 10 (working Auto ADC)
Command : aa 00 90 (End of Auto ADC Process)
: 115200 bps
Command : aa 00 00 (Start factory mode)
Command : ad 00 10 (working Auto ADC)
Command : aa 00 90 (End of Auto ADC Process)
4-2. Manual ADC Process using Service
Remocon
After enter Service Mode by pushing “ADJ” key, execute
“ADC Adjust” by pushing “
“ADC Adjust” by pushing “
G
” key at “0. ADC CALIBRATION”.
4-3. Confirmation
(1) We confirm whether “0xBF(480i)/0xC8(1080i)” address of
EEPROM “0xA2” is “0xAA” or not.
(2) If “0xBF(480i)/0xC8(1080i)” address of EEPROM “0xA2”
isn’t “0xAA”, we adjust once more
(3) We can confirm the ADC values from “0xB9 ~ 0xBE(480i) /
0xC2 ~ (1080i)” addresses in a page “0xA2”
* Manual ADC Confirmation using Service Remocon. After
enter Service Mode by pushing “INSTART” key,
5. DDC EDID Write Confirmation
6. Total Assembly line process
* Caution : Each PCB assembly must be checked by check JIG
set.(Because power PCB Assembly damages to PDP
Module, especially be careful)
Module, especially be careful)
* Caution: Set up “RF mode(noise)” before voltage adjustment.
6-1. POWER PCB Ass’y Voltage
adjustment
(Va, Vs voltage adjustment)
(1) Test equipment : D.M.M 1EA
(2) Connection Diagram for Measuring : refer to fig.1
(2) Connection Diagram for Measuring : refer to fig.1
(fig.1 : Power PCB Assy Voltage adjustment)
6-2. Adjustment method
(1) Vs adjustment (refer fig.1)
1) Connect + terminal of D.M.M. to Vs pin of
P812(42”:P811), connect -terminal to GND pin of
P812(42”:P811)
P812(42”:P811)
2) After turning VR901, voltage of D.M.M adjustment as
same as Vs voltage which on label of panel left/top (
deviation ; ±0.5V)
deviation ; ±0.5V)
(2) Va adjustment (refer fig.1)
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D.M.M. to Va pin of
2) Connect + terminal of D.M.M. to Va pin of
P812(42”:P811), connect -terminal to GND pin of
P811(42”:P812).
P811(42”:P812).
3) After turning VR502,voltage of D.M.M adjustment as
same as Va voltage which on label of panel left/top
(deviation; ±0.5V)
(deviation; ±0.5V)
- 10 -
<XPOWER4 50R1 PSU>
7. DDC EDID Write
MODEL NAME: LG TV (Not necessary)
Caution: Please only check write status in Instart-menu
7-1. Manual Download(using DFT)
PC(for communication through RS-232C), UART baud rate:
115200 bps
Command : aa 00 00 (Start Factory mode)
Command : ae 00 10 (Download All EDID)
Command : aa 00 90 (End of Factory mode)
115200 bps
Command : aa 00 00 (Start Factory mode)
Command : ae 00 10 (Download All EDID)
Command : aa 00 90 (End of Factory mode)
7-2. Manual EDID D/L using Service Remocon
(1) After enter Service Mode by pushing “ADJ” key, select “4.
EDID D/L”.
(2) Finally execute “START” by pushing “
G
” or “
9
”key.
7-3 Full-HD EDID DATA
RGB EDID DATA
HDMI-1 EDID DATA
HDMI-2 EDID DATA
HDMI-3 EDID DATA
8. Adjustment of White Balance
Caution: Press the POWER ON KEY on R/C before W/B adjustment.
8-1. Test Equipment
- Color Analyzer(CS-1000, CA-100+(CH.10), CA-210(CH.10) )
[ Please adjust CA-100+ / CA-210 by CS-1000 before measuring
--> You should use Channel 10 which is Matrix compensated
(White, Red, Green, Blue revised) by CS-1000 and adjust
in accordance with White balance adjustment coordinate.
in accordance with White balance adjustment coordinate.
O
Color temperature standards according to CSM and Module
O
Change target luminance and range of the Auto adjustment
W/B equipment.
O
White balance adjustment coordinate and color temperature
- 11 -
0.003
0.003
0.003
[ PC (for communication through RS-232C) ==> UART Baud rate : 115200 bps
3uv
0.329±0.002
0.329±0.002
0.329
y
0.313±0.002
0.313±0.002
0.313
x
CA-210 (CH.10)
CA-100+ (CH.10)
CS-1000
Warm
0.000
0.000
0.000
3uv
0.293±0.002
0.293±0.002
0.293
y
0.285±0.002
0.285±0.002
0.285
x
CA-210 (CH.10)
CA-100+ (CH.10)
CS-1000
Medium
0.000
0.000
0.000
3uv
0.283±0.002
0.283±0.002
0.283
y
0.276±0.002
0.276±0.002
0.276
x
CA-210 (CH.10)
CA-100+ (CH.10)
CS-1000
Cool
Target luminance
65
Range
20
- 12 -
8-2. Connecting Picture of the Measuring
Instrument
(On Automatic control )
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push control R/C ADJ Key‡ Enter the mode
of White-Balance, the pattern will come out.
auto controller or push control R/C ADJ Key‡ Enter the mode
of White-Balance, the pattern will come out.
8-3. Auto-control interface and directions
(1) Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10ux).
(2) In case of PDP: Measure and adjust after sticking the
Color Analyzer (CA-100+, CA210 ) to the side of the
module.
module.
In case of LCD: Adhere closely the Color Analyzer
(CA210) to the module less than 10cm distance, keep it
with the surface of the Module and Color Analyzer’s Prove
vertically.(80~100°).
(CA210) to the module less than 10cm distance, keep it
with the surface of the Module and Color Analyzer’s Prove
vertically.(80~100°).
(3) Aging time
1) After aging start, keep the power on (no suspension of
power supply) and heat-run over 5 minutes.
2) In case of PDP, keep white pattern using inside pattern.
3) In case of LCD, using ’no signal’ or ‘full white pattern’ or
3) In case of LCD, using ’no signal’ or ‘full white pattern’ or
the others, check the back light on.
O
Auto adjustment Map(RS-232C)
8-4. Manual white Balance
(1) Press the POWER ON KEY on R/C for adjustment and
heat run over 5 minutes.
(2) Zero Calibrate CA-100+ / CA-210, and when controlling,
stick the sensor to the center of PDP module surface.
(3) Press the ADJ KEY on R/C and enter EZ ASJUST
Select “3.W/B ADJUST” and press ENTER(
V
)
Set test-pattern on and display inside pattern.
(4) Control is carried out on three color temperatures, COOL,
MEDIUM, WARM.(Control is carried out three times)
< Temperature: COOL >
- R-offset / G-offset / B-offset is set to 128
- Control R-Gain and G-Gain.
- Each gain is limited to 192
- Control R-Gain and G-Gain.
- Each gain is limited to 192
< Temperature: MEDIUM >
- R-offset / G-offset / B-offset is set to 128
- Control R-Gain and G-Gain.
- Each gain is limited to 192
- Control R-Gain and G-Gain.
- Each gain is limited to 192
< Temperature: WARM >
- R-offset / G-offset / B-offset is set to 128
- Control G-Gain and B-Gain.
- Each gain is limited to 192
- Control G-Gain and B-Gain.
- Each gain is limited to 192
9. HDCP SETTING
(Not necessary)
Caution: Key is saved in external eeprom.
10. RS-232C
Press In-start key and select 4.Baud Rate menu. Check RS-
232C after changing Baud Rate 115200.
232C after changing Baud Rate 115200.
RS-232C COMMAND
CENTER
[CMD ID DATA]
MIN
(DEFAULT)
MAX
Cool Mid
Warm
Cool
Mid
Warm
R Gain
jg
Ja
jd
00
192
192
192
255
G Gain
jh
Jb
je
00
192
192
192
255
B Gain
ji
Jc
jf00
192
192
192
255
R Cut
128
128
128
255
G Cut
128
128
128
255
B Cut
128
128
128
255