LG 50PG60D-SA (CHASSIS:PB82C) Service Manual ▷ View online

- 5 -
<HEAT RUN>
O
Preliminary action is applied to the test for afterimage
discharge detection, and 100% FULL WHITE PATTERN
must be operated automatically.
(1) Pressing Power On key on the adjustment R/C
(2) Full Test Pattern(2 min 30sec) --> Full Black
Pattern(30sec) --> Full White Pattern
(Full White Pattern when the main power is turned on
again after being turned off) 
(3) Pattern Mode is deselected by pressing CH +/-, Exit Key.
[
Set is activated HEAT-RUN without signal generator in this
mode.
5. Voltage Adjustment(50” Model)
5-1. Test Equipment  
(1) D.M.M 1EA
(2) Voltage adjustment bar 
5-2. Connection Diagram for Measuring
Refer to Fig 1.
5-3. Adjustment
(1) Va Voltage Adjustment 
1) Connect + terminal of D.M.M to Va pin of P811 and
connect – terminal  to GND pin of P811.
2) Adjust VR901 voltage to match that of the label on the
Top/Right of the panel. (Deviation : ±0.5V)
(2) 
Vs Voltage Adjustment 
1) Connect + terminal of D.M.M to Vs pin of P811 and
connect – terminal  to GND pin of P811.
2) Adjust VR951 voltage to match that of the label on the
Top/Right of the panel. (Deviation : ±0.5V)
Test Pattern 2min 30sec
Test Pattern 30sec
If you turn on a still screen more than 20 minutes (Especially
Digital pattern(13 CH), Cross Hatch Pattern), an afterimage
may occur in the black level part of the screen.
Each PCB Assy must be checked by Check JIG Set before
assembly. (Especially, be careful Power PCB Assy which can
cause Damage to the PDP Module.)
<Fig. 1>  Connection Diagram for Measuring (Power Board):
LGIT 50” EAY39190301
- 6 -
6EDID(The Extended Display 
Identification Data)/DDC
(Display Data Channel) Download
It is the feature to implement the “Plug and Play” which
automatically reconfigures the user’sl environment to directly
use by exchanging information without any command directly
to the PC or the monitor by the user, which is established by
the VESA
6-1. HDMI EDID Data Input
(1) Required Test Equipment
1) PC, Jig for adjusting DDC. (PC serial to D-sub
Connection equipment)
2) S/W for writing DDC(EDID data write & read)
3) D-Sub cable
4) Jig for HDMI Cable connection
(2) Preparation for Adjustments & 
Setting of Device
1) Set devices as below and turn on the PC and JIG.
2) Open S/W for writing DDC (EDID data write & read).
(operated in DOS mode)
6-2. EDID DATA for 50PG60D-SA
:
EDID for HDMI-1 (DDC (Display Data Channel) Data)
EDID table =
:
EDID for HDMI-2 (DDC (Display Data Channel) Data)
EDID table =
:
EDID for HDMI-3 (DDC (Display Data Channel) Data)
EDID table =
:
EDID Data for RGB 
EDID table =
LCD TV SET
(or Digital Board)
- 7 -
7. Adjustment of White Balance
7-1. Required Test Equipment
(1) Color Analyzer : CA-210 (CH 10), CA-100, CA-100+
=> To adjust color temperature of PDP, CS-1000 is the
Color Analyzer(CA-210) and should be set to use CH 10
in which white, red, green, and blue color are corrected.
Conduct the adjustment according to the coordinates for
White Balance adjustment in the table below.
(2) Computer for adjusting (necessary for the automatic
adjustment, possible to communicate with the RS-232C,
Baud Rate : 115200)
(3) Video Signal Generator MSPG-925F 720p, 216Gray
(Model :217, Pattern 78)
[Full white 216gray]
[
Adjustment Environment and Reference
1) Environment illuminance
Adjust it to 10 LUX or less at the place where the light
source such as lamp should be blocked at maximum.
2) Probe location
- PDP: Locate the Color Analyzer (CA-100, CA-100+,
CA210) close to the module surface to measure and
adjust
- LCD: Maintain the Color Analyzer (CA-210) close to the
module surface by 10cm or less and keep the probe of
the Color Analyzer perpendicular to the module surface
(80°~ 100°).
7-2.  Connection Diagram of Equipment 
for Measuring 
(Automatic Adjustment)
Use the internal pattern to adjust White Balance. The pattern
is automatically given when the automatic adjustment device
is connected or when a user presses ADJ on the remote
controller to start Ez Adjust and then selects 6.White-Balance.
7-3.  White Balance Adjustment Method
Basically it uses the internal pattern but when internal pattern
is not possible, you can select HDMI input for adjustment.
Through the option at the most bottom part of the Ez Adjust
Menu 7.White Balance menu, you can select NONE, INNER
and HDMI, and the default is set to INNER. When the
adjustment cannot be done with the internal pattern, you can
select HDMI input for adjustment. 
For manual adjustment, press the ADJ KEY of the adjustment
R/C to enter Ez Adjust 7.White-Balance, and the pattern is
automatically displayed. (When you set the Option to INNER,
the default is always set to INNER)
(1) Connect the set according to the internal pattern or HDMI
input in accordance with measuring device connection
diagram. 
(2) Set the Baud Rate of RS-232C to 115200. It is set to
115200 as default.
(3) Connect the RS-232C Cable to the set.
(4) Connect the HDMI Cable to the set. (Limited to the set with
HDMI option)
(5) Select and adjust the model applicable to PB82C chassis
from the adjuster.
7-4. Automatic Adjustment
(1) Execute POWER ON(
Â
) of the adjustment R/C to execute
automatic adjustment or set the Baud Rate to 115200.
(2) Always start adjustment with “wb 00 00” and end
adjustment with “wb 00 ff” (Adjust the offset if necessary)
(3) RS-232C command used for the automatic adjustment
(internal pattern)
Connection Diagram for HDMI Input
wb
wb
wb
wb
wb
wb
00
00
00
00
00
00
00
10
1f
20
2f
ff
White Balance Adjustment Start
Gain Adjustment End
Offset Adjustment End
White Balance Adjustment End
RS-232C COMMAND
[CMD     ID     DATA]
Meaning
- 8 -
Ex) Wb 00 00-----white balance Automatic Adjustment Start 
(4) Adjustment Map
(5) Execute POWER ON(
Â
) of the adjustment R/C to execute
automatic adjustment. 
- Set the Baud Rate to 115200.
- Always start adjustment with “wb 00 00” and end
adjustment with “wb 00 ff” 
- Adjust the offset if necessary
7-5. Manual Adjustment
(1) Required Test Equipment: CA-210 (CH-10), CA-100(CH-
10), CA-100+(CH-10)
=> To adjust color temperature of PDP, CS-1000 is the
Color Analyzer and should be set to use CH 10 in which
white, red, green, and blue color are corrected. Conduct
the adjustment according to the coordinates for White
Balance adjustment in the table below.
(2) Enter the ‘Ez - Adjust’ by pressing the ADJ on the Service
R/C.
(3) Select 10.TEST PATTERN using the CH + / - KEY and
press the Enter KEY to execute a heat run for more than
30 minutes. 
(4) Zero Calibrate CA-100+/CA-100 Probe, and stick the
sensor to the center of PDP module surface when you
adjust.
Execute a Zero Calibration for CA-210 Probe and put it at
distance of less than 10Cm from the PDP module surface
center during the adjustment. 
(5) Select ‘7. White-Balance’ of ‘Ez - Adjust’ by pressing the
ADJ KEY on the Service R/C. Then enter adjustment mode
by pressing the Right KEY (
G
) .
(The internal pattern of full white appears by pressing 
G
)
(6) The adjustment is conducted in three levels of color
temperature; COOL, MEDIUM, and WARM.
1) When R GAIN is set to 192
- Control G GAIN and B GAIN by lowering from 192.
2) When B GAIN is set to 192
- Control R GAIN and G GAIN by lowering from 192.
3) When G GAIN is set to 192
- Control R GAIN and B GAIN by lowering from 192.
One of R Gain / G Gain / B Gain should be kept on 192,
and adjust other two lower than 192.
(When R/G/B GAIN are all 192, it is the FULL DYNAMIC
Range of Module)
(7) Use the Vol. +, - key for adjustment.
(8) When the adjustment is completed, press the ENTER (
Á
KEY) button to move to the Ez –Adjust screen. Press the
ADJ KEY to exit the adjustment mode.