- 8 -
9. POWER PCB Assy Voltage
Adjustments 
(Va, Vs Voltage adjustments)
9-1. Test Equipment :
D.M.M. 1EA
9-2.Connection Diagram for Measuring
: refer to Fig.1
9-3. Adjustment Method
(1) Va Adjustment
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D.M.M to Va pin of P811, connect
- terminal to GND pin of P811.
3)  After  turning  VR901,  voltage  of  D.M.M  adjustment  as
same  as  Va  voltage  which  on  label  of  panel  right/top.
(Deviation; ±0.5V)
(2) Vs Adjustment
1) Connect + terminal of D.M.M to Vs pin of P811, connect
– terminal to GND pin of P811.
2)  After  turning  VR951,  voltage  of  D.M.M  adjustment  as
same  as  Va  voltage  which  on  label  of  panel  right/top.
(Deviation; ±0.5V)
10. Adjustment of White Balance
10-1. Required Equipment
(1)  Color  Analyzer  :  CS-100,  CA-100+(CH.10),  CA-
210(CH.10))
*  Please  adjust  CA-100+/CA-210  by  CS-1000  before
measuring.
->  You  should  use  Channel  10  which  is  Matrix
compensated.
Color temperature standards according to CSM and Module.
Change  target  luminance  and  range  of  the  Auto  adjustment
W/B equipment.
White balance adjustment coordinate and color temperature.
Each PCB assembly must be checked by check JIG set.
(Because power PCB Assembly damages to PDP Module,
especially be careful)
(Fig.1) Connection diagram of power adjustment for measuring
* Before adjusting White-balance, the AV ADC should be done.
If ADC status were “NG”, Need to ADC adjustment.
PLASMA
Remark
11000K
9300K
6500K
Cool
Normal
Warm
CSM
65
20
Range
Target luminance
0.276
0.283
0.000
0.276±0.002
0.283±0.002
0.000
0.276±0.002
0.283±0.002
0.000
X
y
uv
Cool
CS-1000
CA-100+(CH.10) CA-210(CH.10)
0.285
0.293
0.000
0.285±0.002
0.293±0.002
0.000
0.285±0.002
0.293±0.002
0.000
X
y
uv
Medium
CS-1000
CA-100+(CH.10) CA-210(CH.10)
0.313
0.329
0.003
0.313±0.002
0.329±0.002
0.003
0.313±0.002
0.329±0.002
0.003
X
y
uv
Warm
CS-1000
CA-100+(CH.10) CA-210(CH.10)
- 9 -
10-2.  Connection Picture of the Measuring
Instrument(On Automatic control)
(1) Inside PATTERN is used when W/B is controlled. Connect
to auto controller or push control R/C IN-START -> Enter
the mode of White-Balance, the pattern will come out.
10-3. Auto-control interface and directions
(1) Adjust in the place where the influx of light like floodlight
around is blocked.(illumination is less than 10ux)
(2) Measure and adjust after sticking the Color Analyzer(CA-
100+, CA210) to the side of the module.
(3) Aging time
- After aging start, keep the power on(no suspension of
power supply) and heat-run over 15 minutes.
- keep white pattern using inside pattern.
Auto adjustment Map(RS-232C)
11. Adjustment of White Balance
(1) Press ADJ KEY on R/C and enter EZ ADJUST.
Select “3. Test Pattern” by using 
D
/
E
(CH+/-) and press
ENTER(
V
)
Select “White” by using 
F
/
G
(VOL+/-) and press ENTER(
V
)
and heat run over 15minutes.
(2)  Zero  Calibrate  CA-100+/CA-210,  and  when  controlling,
stick the sensor to the center of PDP module.
(3) Press ADJ KEY on R/C and enter EZ ADJUST.
Select “2. White Balance” and press 
G
(VOL +).
Set test-pattern on and display inside pattern.
(5) Control is carried out on three color temperatures, COOL,
MEDIUM,WARM.
(Control is carried out thress times)
<Temperature : COOL>
- R-Cut / G-Cut / B-Cut is set to 64/
- Control R-Gain and G-Gain.
- Each Gain is limited to 192.
<Temperature : MEDIUM>
- R-Cut / G-Cut / B-Cut is set to 64/
- Control R-Gain and G-Gain.
- Each Gain is limited to 192.
<Temperature : WARM>
- R-Cut / G-Cut / B-Cut is set to 64/
- Control G-Gain and B-Gain.
- Each Gain is limited to 192.
12. Input the Shipping Option Data 
1) Push the IN-START key in a Adjust Remocon.
2) Input the Option Number that was specified in the BOM, into
the Shipping area.
3) The work is finished, Push 
V
Key.
13. Set Information
(Serial No& Model name)
13-1. Check the serial number & Model Name
(1) Push the menu button in DTV mode.
(2) Select the SETUP -> Diagnostics -> To set.
(3) Check the Serial Number.
(Fig.6) Auto AV(CVBS) Color Balance Test Pattern
Full White Pattern
RS-232C Communication
CA-210
Color
ANALYZER
TYPE : CA-210
R Gain
G Gain
B Gain
R Offset
G Offset
B Offset
Cool
MedWarm
Cool
Med
Warm
jg
Ja
js
00
192
192
192
255
jh
Jb
je
00
192
192
192
255
ji
Jc
jf
00
192
192
192
255
62
63
66
128
58
57
62
128
71
71
64
128
RS-232C COMMAND
[CMD ID DATA]
Min
CENTER
(DEFAULT)
MAX
50PG1
- 10 -
14. SET factoring condition
(1) This adjustment is setting factory shipment mode.
(2) Push the IN-STOP key of adjustment remote controller before
the factory shipment.
15. Flash Memory Download
15-1. Configuration Environment
(1) To installation the ‘LG Term’, extract ‘lgterm.zip’ to a folder.
(2) Execute ‘lgterm.exe’.
(3) Before downloading epk file, change the baud-rate value.
1) Press the ‘IN-START’ button.
2) Select the ‘System’ menu.
3) Enter ‘115200bps’ on the ‘Baudrate’.
4) Exit the menu.
15-2. Download epk file using ‘LG Term’
(1) Execute ‘lgterm.exe’
(2) Select a serial port and change a baud-rate value.
1)  Select  a  serial  port  which  is  connected  through  a  RS-
232 cable on ‘Setup’ Menu.
* If the selected port is not connected, a warning message
will appear.
2)  Change  the  baud-rate  from  a  default  value  to
‘115200bps’ on ‘Setup’ Menu.
(3) Press the OK button.
(4) Turn on the TV set and press the ‘Enter’ key at the same
time.
(5) Douglas prompt will appear.
(6) Insert ‘swuhz’ and enter.
(7) Change the baud-rate to ‘460800bps’ on ‘Setup’ Menu.
(8) Press ‘Alt+F’, ‘T’, ‘Z’, ‘S’ in order.
(9) Select the epk file.
(10) It will take 4~5 minutes.
(11) To apply last epk file, TV set should be restarted.
1
2
3
4
5
6
7
8
9
10
Antenna
10
Off
16:9
1
Vivid
Medium
Off
Auto
Standard
Off
0
On
On
--
Off
On
Off
Normal
Off
Item
Condition
No
Remark
Input Mode
Volume Level
Mute
Aspect Ratio
SET ID
Picture  PSM
Color Temp.
Advanced
Cinema
Black level
SoundSSM
AVL
Balance
TV Speaker
Time
Auto Clock
Manual Clock
Off Timer / On Timer
Sleep Timer / Auto Off
Option
SIMPLINK
Key Lock
ISM Method
Power Saving
Channel Memory    Analog
Digital
- 11 -
TROUBLE SHOOTING GUIDE
1. Power Board 
1-1. The whole flowchart which it follows in voltage output state
Start check
Manufacture enterprise
meaning of a passage
1. Check the Power Off
condition.
Doesn't the 
screen whole come
out?
Is it identical 
with Power Off
condition?
Yes
Yes
No
No
No
No
No
2. Check the Interface
signal condition.
Is the Interface 
signal operated?
Yes
3. Check the St-by 5V
signal circuit.
Doesn't the 
low pressure output
come out?
Doesn't the 
St-by 5V signal 
come out?
Yes
Yes
No
4. Check the 5V Monitor
signal circuit.
Doesn't the 
5V Monitor signal 
come out?
Yes
7. Check the VSC Vs-ON
signal 
Doesn't the 
high tension output
come out?
Doesn't the 
VSC signal Vs-ON
come out?
Yes
Yes
Does
high tension 
output voltage Drop
occur?
When the
Y B/D Module
input connector is
removed, does output
voltage drop
occur?
When the
Y, Z B/D Module
input connector is remove,
does Power Board hightension 
output voltage Drop
occur?
Yes
No
No
9. Check the Power
Board Output high
tension circuit
Yes
10. Check the Z B/D
Module output circuit
Yes
When the
Z B/D Module 
input connector is
removed, does output
voltage Drop 
occurs?
11. Check the Y B/D
Module output circuit
Yes
No
8. Check the Vs, Va
voltage output circuit.
Doesn't the 
Vs, Va voltage output
come out?
Yes
No
No
5. Check the VSC RL-ON
signal.
Doesn't the 
VSC signal RL-ON
come out?
Yes
6. Check the VSC low
pressure output
Doesn't the 
VSC low pressure
output come out?
Yes
Page of 34
Display