DOWNLOAD LG 50PG20-UA (CHASSIS:PU84A) Service Manual ↓ Size: 10.03 MB | Pages: 48 in PDF or view online for FREE

Model
50PG20-UA (CHASSIS:PU84A)
Pages
48
Size
10.03 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / Plasma
File
50pg20-ua-chassis-pu84a.pdf
Date

LG 50PG20-UA (CHASSIS:PU84A) Service Manual ▷ View online

- 7 -
4-3. Confirmation
(1) We confirm whether “0xBF(480i)/0xC8(1080i)” address of
EEPROM “0xA2” is “0xAA” or not. 
(2) If “0xBF(480i)/0xC8(1080i)” address of EEPROM “0xA2”
isn’t “0xAA”, we adjust once more
(3) We can confirm the ADC values from “0xB9 ~ 0xBE(480i) /
0xC2 ~ (1080i)” addresses in a page “0xA2”
[
Manual ADC Confirmation using Service Remocon. After enter
Service Mode by pushing “INSTART” key.
Caution: Each PCB assembly must be checked by check JIG set.
(Because power PCB Assembly damages to PDP
Module, especially be careful)
Caution: Set up “RF mode(noise)” before voltage adjustment.
5. POWER PCB Ass’y Voltage 
Adjustment
(Va, Vs voltage Adjustment)
5-1. Test Equipment:
D.M.M 1EA
5-2. Connection Diagram for Measuring
Refer to Fig.1, Fig 2
5-3. Adjustment Method 
(1) 50” Va Adjustment (refer fig.1)
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D.M.M. to Va pin of P802,
connect-terminal to GND pin of P802.
3) After turning VR902,voltage of D.M.M adjustment as
same as Va voltage which on label of panel right/top
(deviation; ±0.5V)
(2) 50” Vs Adjustment (refer fig.1)
1) Connect + terminal of D.M.M. to Vs pin of P802, connect
-terminal to GND pin of P802.
2) After turning VR901, voltage of D.M.M adjustment as
same as Vs voltage which on label of panel right/top
(deviation ; ±0.5V)
(3) 42” Va Adjustment (refer fig.2)    
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D.M.M. to Va pin of P811, connect
-terminal to GND pin of P811.
3) After turning VR901,voltage of D.M.M adjustment as
same as Va voltage which on label of panel right/top
(deviation; ±0.5V)
(4) 42” Vs Adjustment (refer fig.2)
1) Connect + terminal of D. M..M. to Vs pin of P811,
connect -terminal to GND pin of P811.
2) After turning VR951, voltage of D.M.M adjustment as
same as Vs voltage which on label of panel right/top
(deviation ; ±0.5V)
ADJUSTMENT INSTRUCTIONS
(Fig. 1) 50inch Power PCB Assy Voltage Adjustment
(Fig. 2) 42inch Power PCB Assy Voltage Adjustment
- 8 -
6. DDC EDID Write 
(MODEL NAME:  LG TV)
Caution: Press the POWER ON KEY on R/C before EDID download.
EDID download is processed automatically through RS-232C
PC(for communication through RS-232C), UART baud rate:
115200 bps
O
EDID Download Protocol (RS-232C)
O
HDMI-1 EDID DATA
O
HDMI-2 EDID DATA
O
HDMI-3 EDID DATA
O
RGB EDID DATA
ADJUSTMENT INSTRUCTIONS
- 9 -
7. Adjustment of White Balance
Caution: Press the POWER ON KEY on R/C before W/B adjustment.
7-1. Test Equipment
- Color Analyzer (CS-1000, CA-100+(CH.10), CA-210(CH.10))
[
Please adjust CA-100+ / CA-210 by CS-1000 before measuring
--> You should use Channel 10 which is Matrix compensated
(White, Red, Green, Blue revised) by CS-1000 and adjust
in accordance with White balance adjustment coordinate.
O
Color temperature standards according to CSM and Module 
O
Change target luminance and range of the Auto adjustment
W/B equipment.
O
White balance adjustment coordinate and color temperature
7-2. Connecting Picture of the Measuring 
Instrument
(On Automatic control )
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push control R/C ADJ Key—> Enter the
mode of White-Balance, the pattern will come out.
7-3. Auto-control Interface and Directions
(1) Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10ux).
(2) In case of PDP: Measure and adjust after sticking the Color
Analyzer (CA-100+, CA210) to the side of the module. 
In case of LCD: Adhere closely  the Color Analyzer (
CA210 ) to the module less than 10cm distance, keep it
with the surface of the Module and Color Analyzer’s Prove
vertically.(80~100°).
(3) Aging time  
1) After aging start, keep the power on (no suspension of
power supply) and heat-run over 15 minutes.
2) In case of PDP, keep white pattern using inside pattern.
3) In case of LCD, using ’no signal’ or ‘full white pattern’ or
the others, check the back light on.
O
Auto Adjustment Map(RS-232C)
7-4. Manual White Balance 
1) Press the ADJ KEY on R/C and enter EZ ASJUST
Select “3. Test Pattern” by using 
D
/
E
(CH +/-) and press
ENTER(
V
)
Select “White” by using 
F
/
G
(VOL +/-) and press
ENTER(
V
) and heat run over 15 minutes.
2) Zero Calibrate CA-100+ / CA-210, and when controlling,
stick the sensor to the center of PDP module surface.
3) Press the ADJ KEY on R/C and enter EZ ASJUST
Select “2. White Balance” and press 
G
(VOL +)
Set test-pattern on and display inside pattern. 
4) Control is carried out on three color temperatures, COOL,
MEDIUM, WARM. 
(Control is carried out three times)
<Temperature: COOL>
- R-Cut / G-Cut / B-Cut is set to 64
- Control R-Gain and G-Gain.
- Each gain is limited to 192
<Temperature: MEDIUM>
- R-Cut / G-Cut / B-Cut is set to 64
- Control R-Gain and G-Gain.
- Each gain is limited to 192
ADJUSTMENT INSTRUCTIONS
- 10 -
<Temperature: WARM>
- R-Cut / G-Cut / B-Cut is set to 64
- Control G-Gain and B-Gain.
- Each gain is limited to 192
8. HDCP(High-Bandwidth Digital
Contents Protection) SETTING
(1) Connect D-sub Signal Cable to D-Sub Jack
(2) Input HDCP key with HDCP-key- in-program
(3) HDCP Key value is stored on EEPROM(AT24C512) which
is 80~A1 addresses of  0xA0~0xA2 page
(4) AC off/ on and on HDCP button of MSPG925 and confirm
whether picture is displayed or not of using MSPG925
(5) HDCP Key value is different among the sets. 
9. RS-232C 
Press In-start key and select 3.Baud Rate menu. Check RS-
232C after changing Baud Rate 115200.
10. OPTION
(1) Press ADJ R/C In-start key and select 0.AREA OPTION
(2) Select Country by using 
F
/
G
(VOL +/-) in accordance with
destination
ADJUSTMENT INSTRUCTIONS
Page of 48
Display