- 5 -
4. POWER PCB Assy Voltage
Adjustment
(Va, Vs voltage adjustment)
4-1. Test equipment:
D.M.M 1EA
4-2. Connection Diagram for Measuring
Refer to fig. 4
4-3. Adjustment Method
(1) Va Adjustment
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D. M..M. to Va pin of P807, connect -
2) Connect + terminal of D. M..M. to Va pin of P807, connect -
terminal to GND pin of P807.
3) After turning RV501,voltage of D.M.M adjustment as same as
Va voltage which on label of panel right/top (deviation; ±0.5V)
(2) Vs Adjustment
1) Connect + terminal of D. M..M. to Vs pin of P807, connect -
terminal to GND pin of P807.
2) After turning RV 401, voltage of D.M.M adjustment as same as
Vs voltage which on label of panel right/top (deviation; ±0.5V)
5. EDID(The Extended Display
Identification Data) / DDC(Display
Data Channel) Download
Data Channel) Download
5-1. Required Test Equipment
(1) Adjusting PC with S/W for writing EDID Data(S/W: EDID
TESTER Ver.2.5)
(2) A Jig for EDID Download
(3) Cable : Serial(9Pin or USB) to D-sub 15Pin cable, D-sub
(3) Cable : Serial(9Pin or USB) to D-sub 15Pin cable, D-sub
15Pin cable, DVI to HDMI cable.
5-2. Setting of Device
5-3. Preparation for Adjustment
(1) As above <Fig. 5>, Connect the Set, EDID Download Jig,,
PC & Cable
(2) Turn on the PC & EDID Download Jig. And Execute the
S/W : EDID TESTER Ver.2.5
(3) Set up the S/W option
Repeat Number : 5
Device Address : A0
Device Address : A0
PageByte : 8
(4) Power on the Set
<Fig. 5> Connection Diagram of DDC Download
<Fig. 4-1> 42 inch: 6709900019A
<Fig. 4-2> 42 inch: EAY32808901
<Fig. 4-3> 50 inch: 6709900020A
Connection Diagram of Power Adjustment for Measuring
Caution: Each PCB assembly must be checked by check JIG
set. (Because power PCB Assembly damages to PDP Module,
especially be careful)
set. (Because power PCB Assembly damages to PDP Module,
especially be careful)
- 6 -
5-4. Sequence of Adjustment
(1) EDID Download
1) Init the data
2) Load the EDID data.(Open File)
3) Set the S/W as below.
4) Push the “Write Data & Verify” button. And confirm “Yes”.
5) If the writing is finished, you will see the “ OK” message.
4) Push the “Write Data & Verify” button. And confirm “Yes”.
5) If the writing is finished, you will see the “ OK” message.
6) If TV has two HDMI, you must download two times for each
HDMI.
5-5. EDID Data
(1) ANALOG RGB
(2) HDMI_1
(3) HDMI_2
O
Product ID
O
Serial No: Controlled on production line.
O
Month, Year: Controlled on production line
ex) Monthly: ‘01’ ==> ‘01’
Year : ‘2007’ ==> ‘11’
O
Checksum: Changeable by total EDID data
[Anaolg file] (for RGB)
[Digital file] (for HDMI)
- 7 -
6. Select Panel size and tool.
Before AV ADC Calibration, should be select the “Tool Option ”
(1) Press ADJ Key in the Adjust remocon.
(2) Select “Tool Option1” by using
(2) Select “Tool Option1” by using
D
/
E
(CH+/-) key, and
press
A
(ENTER).
(3) Change “Inch” and “Tool” according to the inch of model
name.
(4) After changing the panel size, push the EXIT Key.
7. ADC Calibration
[
Caution:
- System control RS-232 Host should be “PC” for
adjustment.
- Before AV ADC Calibration, execute the “Panel size
selection”
8. Auto AV(CVBS) Color Balance
8-1. Requirement
(1) This AV color balance adjustment should be performed
before White Balance Adjustment.
(2) Mandatory point : All models are adjusted twice of NTSC
and PAL in AV mode.
8-2. Required Equipment
(1) Remote controller for adjustment
(2) MSPG-925FS Pattern Generator (Which has Video Signal:
(2) MSPG-925FS Pattern Generator (Which has Video Signal:
7 Color Bar Pattern shown in Fig. 7).
Model: 207 / Pattern: 65 Case 2) EC and FC model use
NTSC_J (composite signal)
Model: 207 / Pattern: 65 Case 2) EC and FC model use
NTSC_J (composite signal)
8-3. Method of Auto RF / AV / S-VIDEO
Color Balance(NTSC_J)
(1) Input the Video signal: 7 color Bar signal into AV1.
(2) Set the PSM to Dynamic mode in the Picture menu
(2) Set the PSM to Dynamic mode in the Picture menu
(3) Press INSTART key on R/C for adjustment.
(4) Press the
(4) Press the
G
(Vol. +) key operate to set, then it becomes
automatically.
(5) Auto-RGB OK means completed adjustment.
9. Adjustment of Component
9-1. Required Equipment
(1) Remote controller for adjustment
(2) MSPG-925FS Pattern Generator (Which has Video Signal:
(2) MSPG-925FS Pattern Generator (Which has Video Signal:
7 Color Bar Pattern shown in Fig. 7).
Model: 216 / Pattern: 65
Model: 216 / Pattern: 65
9-2. Method of Auto Component Color Balance
(1) Input the Component 720p/60Hz 7 Color Bar(MSPG-
925FS model:216, pattern:65) signal into Component.
(2) Set the PSM to Dynamic mode in the Picture menu.
<Fig. 6> Color Bar Signal
<Fig. 7> Color Bar Signal
(3) Press IN-START key on R/C for adjustment.
(4) Press the
(4) Press the
G
(Vol. +) key to operate the set, then it
becomes automatically.
(5) Auto-RGB OK means the adjustment is completed.
10. Adjustment of RGB
10-1. Required Equipments
(1) Remote controller for adjustment
(2) MSPG-925FS Pattern Generator
(2) MSPG-925FS Pattern Generator
(Which has XGA [1024*768] 60Hz, 7 color bar 100%
shown in Fig. 8)
shown in Fig. 8)
10-2. Method of Auto RGB Color Balance
(1) Input the PC 1024x768 @ 60Hz 7 color bar 100% (MSPG-
925FS, Model:60, Pattern:65) into RGB. (using D-sub to D-
sub cable)
sub cable)
(2) Set the PSM to Dynamic mode in Picture menu.
(3) Press the IN-START key on R/C for adjustment.
(3) Press the IN-START key on R/C for adjustment.
(4) Press the
G
(Vol. +) key to operate the set, then it
becomes automatically
(5) Auto-RGB OK means the adjustment is completed
11. Adjustment of White Balance
Before adjusting White-balance , the AV ADC should be done.
11-1. Required Equipment
(1) Remote controller for adjustment
(2) Color Analyzer ( CA-100+ or same product ) : CH 10
(2) Color Analyzer ( CA-100+ or same product ) : CH 10
(PDP) , CH 9 (LCD)
(3) Auto W/B adjustment instrument(only for Auto adjustment)
(4) AV Pattern Generator
(4) AV Pattern Generator
O
Color temperature standards according to CSM and Module
O
White balance adjustment coordinate and color temperature
PC (for communication through RS-232C) ==> UART Baud
rate : 115200 bps
rate : 115200 bps
[
Connecting picture of the measuring instrument (On
Automatic control )
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push control R/C IN-START
==> Enter the mode of White-Balance, the pattern will come
out.
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push control R/C IN-START
==> Enter the mode of White-Balance, the pattern will come
out.
O
Auto Adjustment Map(RS-232C)
- 8 -
<Fig. 8> Color Bar Signal
<Fig. 9> Connecting Picture(On Automatic Control)