- 6 -
5. Factory Adjustment
->  PU21A/PB21A  :  USE  INTERNAL ADC(LM1)  :  using  internal 
pattern.
5.1.  Auto Adjust Component 480i/1080p RGB 
1080p 
■ Summary :  Adjustment  component  480i/1080i  and  RGB 
1080p is Gain and Black level setting at Analog 
to  Digital  converter,  and  compensate  the  RGB 
deviation
■ Using instrument 
●  Adjustment  remocon,  801GF(802B,  802F,  802R)  or 
MSPG925FA pattern generator
  ( It  can  output  480i/1080i  horizontal  100%  color  bar 
pattern  signal,  and  its  output  level  must  setting 
0.7V±0.1V p-p correctly)
●  You  must  make  it  sure  its  resolution  and  pattern  cause 
every instrument can have different setting
●  Adjustment  method  480i  Comp1, Adjust  1080p  Comp1/
RGB (Factory adjustment)
● ADC 480i Component1 adjustment
- Check connection of Component1 
- MSPG-925FA -> Model: 209, Pattern 65
●  Set  Component  480i  mode  and  100%  Horizontal  Color 
Bar  Pattern(HozTV31Bar),  then  set  TV  set  to 
Component1 mode and its screen to “NORMAL” 
● ADC 1080p Component1 / RGB adjustment
- Check connection both of Component1 and RGB
- MSPG-925FA -> Model: 225, Pattern 65
●  Set Component 1080p mode and 100% Horizontal Color 
Bar  Pattern(HozTV31Bar),  then  set  TV  set  to 
Component1 mode and its screen to “NORMAL” 
●  After get each the signal, wait more a second and enter 
the  “IN-START”  with  press  IN-START  key  of  Service 
remocon.  After  then  select  “7.  External  ADC”  with 
navigator button and press “Enter”. 
●  After Then  Press  key  of  Service  remocon  “Right Arrow 
(VOL+)”
● You can see “ADC Component1 Success”
● Component1 1080p, RGB 1080p Adjust is same method.
●  Component  1080p Adjustment  in  Component1  input 
mode
● RGB 1080p adjustment in RGB input mode
●  If  you  success  RGB  1080p Adjust. You  can  see  “ADC 
RGB-DTV Success”
* caution : Set Volume 0 after adjustment
-  ADJ(EZ  ADJUST)  ->  6.ADC  Calibration  ->  ADC 
Calibration(START) 
*  EDID  (The  Extended  Display  Identification  Data)/DDC 
(Display Data Channel) Download.
■ Summary
●  It is established in VESA, for communication between 
PC  and  Monitor  without  order  from  user  for  building 
user  condition.  It  helps  to  make  easily  use  realize 
“Plug and Play” function. 
● For EDID data write, we use DDC2B protocol.
- Auto Download
■ After enter Service Mode by pushing “ADJ” key,
■ Enter EDID D/L mode.
■ Enter “START” by pushing “OK” key. 
Caution: 
-  Never  connect  HDMI  &  D-sub  Cable  when  the  user 
downloading .
- Use the proper cables below for EDID Writing
< Adjustment pattern : 480i / 1080p 60Hz Pattern >
- 7 -
(PU21A)
* Edid data and Model option download(RS232)
- Manual Download 
■ Write HDMI EDID data
● Using instruments
-  Jig.  (PC  Serial  to  D-Sub  connection)  for  PC,  DDC 
adjustment.
- S/W for DDC recording (EDID data write and read)
- D-sub jack
- Additional HDMI cable connection Jig.
● Preparing and setting.
-  Set instruments and Jig. Like pic.5), then turn on PC 
and Jig. 
- Operate DDC write S/W (EDID write & read)
- It will operate in the DOS mode.
■ EDID data (Model name = LG TV)
 - RGB FHD 
- South Centural America _2D_FHD HDMI  
NO
Enter  
download MODE
EDID data Model
option download
Item
download ‘Mode In’
download
CMD 1
A
A
CMD 2
A
E
Data 0
0
00
0
10
When transfer the  
‘Mode In’,
Carry the command.
Automatically download
(The use of a internal 
pattern)
< For write EDID data, setting Jig and another instruments >
00 FF FF FF FF FF FF 00 1E 6D 01 00 01 01 01 01 
01 16 01 03 68 A0 5A 78 0A EE 91 A3 54 4C 99 26 
0F 50 54 A1 08 00 31 40 45 40 61 40 81 80 D1 C0 
01 01 01 01 01 01 1A 36 80 A0 70 38 1F 40 30 20 
25 00 40 84 63 00 00 1A 66 21 50 B0 51 00 1B 30 
40 70 36 00 40 84 63 00 00 1E 00 00 00 FD 00 3A 
3E 1E 53 10 00 0A 20 20 20 20 20 20 00 00 00 FC 
00 4C 47 20 54 56 0A 20 20 20 20 20 20 20 00 ED 
00 FF FF FF FF FF FF 00 1E 6D 01 00 01 01 01 01 
01 16 01 03 80 A0 5A 78 0A EE 91 A3 54 4C 99 26 
0F 50 54 A1 08 00 31 40 45 40 61 40 81 80 D1 C0 
01 01 01 01 01 01 1A 36 80 A0 70 38 1F 40 30 20 
25 00 40 84 63 00 00 1A 66 21 50 B0 51 00 1B 30 
40 70 36 00 40 84 63 00 00 1E 00 00 00 FD 00 3A 
3E 1E 53 10 00 0A 20 20 20 20 20 20 00 00 00 FC 
00 4C 47 20 54 56 0A 20 20 20 20 20 20 20 01 D4 
02 03 27 F1 4F 90 1F 04 13 05 14 03 02 12 20 22 
15 11 16 01 26 15 07 50 09 57 07 67 03 0C 00 10 
00 B8 2D E3 05 03 01 02 3A 80 18 71 38 2D 40 58 
2C 45 00 40 84 63 00 00 1E 01 1D 80 18 71 1C 16 
20 58 2C 25 00 40 84 63 00 00 9E 01 1D 00 72 51 
D0 1E 20 6E 28 55 00 40 84 63 00 00 1E 0E 1F 00 
80 51 00 1E 30 40 80 37 00 40 84 63 00 00 1C 00 
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 4B 
- 8 -
- South Centural America _2D_FHD HDMI 2
- South Centural America _2D_FHD HDMI 3
-  See Working Guide if you want more information about EDID 
communication.
- Adjustment Color Temperature(White balance)
■ Using Instruments
● Color Analyzer: CA-210 (CH 10)
-  Using LCD color temperature, Color Analyzer (CA-
210) must use CH 10, which Matrix compensated 
(White, Red, Green, Blue compensation) with CS-
2100. See the Coordination bellowed one. 
●  Auto-adjustment Equipment (It needs when Auto-adjust-
ment – It is availed communicate with RS-232C : Baud 
rate: 115200) 
●  Video Signal Generator MSPG-925F 720p, 216Gray 
(Model: 217, Pattern 78)
■ Connection Diagram (Auto Adjustment)
● Using Inner Pattern
● Using HDMI input
■ White Balance Adjustment 
If you can’t adjust with inner pattern, then you can adjust 
it using HDMI pattern. You can select option at “Ez-Adjust 
Menu – 7. White Balance” there items “NONE, INNER, 
HDMI”. It is normally setting at inner basically. If you can’t 
adjust using inner pattern you can select HDMI item, and 
you can adjust.
In manual Adjust case, if you press ADJ button of service 
remocon, and enter “Ez-Adjust Menu – 7. White Balance”, 
then automatically inner pattern operates. (In case of 
“Inner” originally “Test-Pattern. On” will be selected in The 
“Test-Pattern. On/Off”. 
● Connect all cables and equipments like Pic.5)
●  Set Baud Rate of RS-232C to 115200. It may set 115200 
orignally.
● Connect RS-232C cable to set
● Connect HDMI cable to set
< connection Diagram for Adjustment White balance >
00 FF FF FF FF FF FF 00 1E 6D 01 00 01 01 01 01 
01 16 01 03 80 A0 5A 78 0A EE 91 A3 54 4C 99 26 
0F 50 54 A1 08 00 31 40 45 40 61 40 81 80 D1 C0 
01 01 01 01 01 01 1A 36 80 A0 70 38 1F 40 30 20 
25 00 40 84 63 00 00 1A 66 21 50 B0 51 00 1B 30 
40 70 36 00 40 84 63 00 00 1E 00 00 00 FD 00 3A 
3E 1E 53 10 00 0A 20 20 20 20 20 20 00 00 00 FC 
00 4C 47 20 54 56 0A 20 20 20 20 20 20 20 01 D4 
02 03 27 F1 4F 90 1F 04 13 05 14 03 02 12 20 22 
15 11 16 01 26 15 07 50 09 57 07 67 03 0C 00 20 
00 B8 2D E3 05 03 01 02 3A 80 18 71 38 2D 40 58 
2C 45 00 40 84 63 00 00 1E 01 1D 80 18 71 1C 16 
20 58 2C 25 00 40 84 63 00 00 9E 01 1D 00 72 51 
D0 1E 20 6E 28 55 00 40 84 63 00 00 1E 0E 1F 00 
80 51 00 1E 30 40 80 37 00 40 84 63 00 00 1C 00 
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 3B 
00 FF FF FF FF FF FF 00 1E 6D 01 00 01 01 01 01 
01 16 01 03 80 A0 5A 78 0A EE 91 A3 54 4C 99 26 
0F 50 54 A1 08 00 31 40 45 40 61 40 81 80 D1 C0 
01 01 01 01 01 01 1A 36 80 A0 70 38 1F 40 30 20 
25 00 40 84 63 00 00 1A 66 21 50 B0 51 00 1B 30 
40 70 36 00 40 84 63 00 00 1E 00 00 00 FD 00 3A 
3E 1E 53 10 00 0A 20 20 20 20 20 20 00 00 00 FC 
00 4C 47 20 54 56 0A 20 20 20 20 20 20 20 01 D4 
02 03 27 F1 4F 90 1F 04 13 05 14 03 02 12 20 22 
15 11 16 01 26 15 07 50 09 57 07 67 03 0C 00 30 
00 B8 2D E3 05 03 01 02 3A 80 18 71 38 2D 40 58 
2C 45 00 40 84 63 00 00 1E 01 1D 80 18 71 1C 16 
20 58 2C 25 00 40 84 63 00 00 9E 01 1D 00 72 51 
D0 1E 20 6E 28 55 00 40 84 63 00 00 1E 0E 1F 00 
80 51 00 1E 30 40 80 37 00 40 84 63 00 00 1C 00 
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 2B 
- 9 -
■ RS-232C Command (Commonly apply)
● “wb 00 00”: Start Auto-adjustment of white balance.
● “wb 00 10”: Start Gain Adjustment (Inner pattern) 
● “jb 00 c0” : 
● …
● “wb 00 1f”: End of Adjustment
*  If it needs, offset adjustment (wb 00 20-start, wb 00 2f-
end)
●  “wb 00 ff”: End of white balance adjustment (inner pattern 
disappear)
■ Adjustment Mapping information
●  When Color temperature (White balance) Adjustment 
(Automatically)
-  Press “Power only key” of service remocon and operate 
automatically adjustment.
- Set BaudRate to 115200.
● You must start “wb 00 00” and finish it “wb 00 ff”.
● If it needs, then adjustment “Offset”.
■ White Balance Adjustment (Manual adjustment)
● Test Equipment: CA-210
-  Using PDP color temperature, Color Analyzer (CA-210) 
must use CH 10, which Matrix compensated (White, Red, 
Green, Blue compensation) with CS-2100. See the 
Coordination bellowed one. 
● Manual adjustment sequence is like bellowed one.
-  Turn to “Ez-Adjust” mode with press ADJ button of service 
remocon.
-  Select “10.Test Pattern” with CH+/- button and press 
enter. Then set will go on Heat-run mode. Over 30 
minutes set let on Heat-run mode.
-  Let CA-210 to zero calibration and must has gap more 
10cm from center of PDP module when adjustment. 
-  Press “ADJ” button of service remocon and select 
“7.White-Balance” in “Ez-Adjust” then press “►” button of 
navigation key. (When press “►” button then set will go to 
full white mode)
- Adjust at three mode (Cool, Medium, Warm)
- If “cool” mode 
   Let B-Gain to 192 and R, G, B-Cut to 64 and then control 
R, G gain adjustment High Light adjustment.
-  If “Medium” and “Warm” mode Let R-Gain to 192 and R, 
G, B-Cut to 64 and then control G, B gain adjustment 
High Light adjustment.
- All of the three mode 
   Let R-Gain to 192 and R, G, B-Cut to 64 and then control 
G, B gain adjustment High Light adjustment.
- With volume button (+/-) you can adjust.
-  After all adjustment finished, with Enter (■ key) turn to 
Ez-Adjust mode. Then with ADJ button, exit from 
adjustment mode
Attachment:  White Balance adjustment coordination and color 
temperature.
● Using CS-1000 Equipment. 
- COOL : T=11000K, ∆uv=0.000, x=0.276 y=0.283 
- MEDIUM  : T=9300K, ∆uv=0.000, x=0.285 y=0.293 
- WARM  : T=6500K, ∆uv=0.000, x=0.313 y=0.329 
●  When tester will measure on Cool condition, adjust W30 on 
TV display menu.
●  When tester will measure on medium condition, adjust 0 on 
TV display menu.
RS-232C 
COMMAND
[CMD ID DATA]
M
I
N
CENTER
(DEFAULT)
M
A
X
Cool Mid Warm
Cool Mid Warm
R Gain
jg
Ja
jd
00
184 192
192
192
G Gain
jh
Jb
je
00
187 183
159
192
B Gain
ji
Jc
jf
00
192 161
95
192
R Cut
64
64
64
127
G Cut
64
64
64
127
B Cut
64
64
64
127
RS-232C COMMAND
[CMD           ID        DATA]
Meaning
wb
00
00
White Balance adjustment start.
wb
00
10
Start of adjust gain
(Inner white pattern)
wb
00
1f
End of gain adjust
wb
00
20
Start of offset adjust
(Inner white pattern)
wb
00
2f
End of offset adjust
wb
00
ff
End of White Balance adjust