LG 47LV5700-CA (CHASSIS:LC12E) Service Manual ▷ View online
LGE LCD Division LG(51)
Establish:
Reform:
LC12E Adjust Specification
C2-2230
LG Electronics
5.4 EYE-Q function check
Step 1) Turn on TV
Step 2) Press EYE key of Adj. R/C
Step 3) Cover the Eye Q II sensor on the front of the using your hand and wait for 6 seconds
Step 4) Confirm that R/G/B value is lower than 10 of the “Raw Data (Sensor data, Back light )” . If after
Step 2) Press EYE key of Adj. R/C
Step 3) Cover the Eye Q II sensor on the front of the using your hand and wait for 6 seconds
Step 4) Confirm that R/G/B value is lower than 10 of the “Raw Data (Sensor data, Back light )” . If after
6 seconds, R/G/B value is not lower than 10, replace Eye Q II sensor
Step 5) Remove your hand from the Eye Q II sensor and wait for 6 seconds
Step 6) Confirm that “ok” pop up.
If change is not seen, replace Eye Q II sensor
Step 6) Confirm that “ok” pop up.
If change is not seen, replace Eye Q II sensor
5.5 Local Dimming Function Check
Step 1) Turn on TV
Step 2) At the Local Dimming mode, module Edge Backlight moving Top to Bottom
Back light of IOP module moving
Step 3) confirm the Local Dimming mode
Step 4) Press “exit” Key
LGE LCD Division LG(51)
Establish:
Reform:
LC12E Adjust Specification
C2-2230
LG Electronics
5.6 Magic Motion Remocon test
- equipment : RF Remocon for test, IR-KEY-Code Remocon for test
- You must confirm the battery power of RF-Remocon before test
- You must confirm the battery power of RF-Remocon before test
(recommend that change the battery per every lot)
- Sequence (test)
a) if you select the ‘start key(Mute)’ on the controller, you can pairing with the TV SET.
b) You can check the cursor on the TV Screen, when select the ‘OK Key’ on the controller
b) You can check the cursor on the TV Screen, when select the ‘OK Key’ on the controller
c) You must remove the pairing with the TV Set by select ‘Vol+(STOP) Key’ on the controller
2) Depending on destination, select Country Group Code 04 or Country Group EU then on
the lower Country option, select US, CA, MX. Selection is done using +,
- or ▶◀
KEY
5.7 Tool Option selection
▪ Method: Press Adj. key on the Adj. R/C, then select Tool option.
5.8 Ship-out mode check (In-stop)
▪ After final inspection, press In-Stop key of the Adj. R/C and check that the unit goes to Stand-
▪ Method: Press Adj. key on the Adj. R/C, then select Tool option.
5.8 Ship-out mode check (In-stop)
▪ After final inspection, press In-Stop key of the Adj. R/C and check that the unit goes to Stand-
LGE LCD Division LG(51)
Establish:
Reform:
LC12E Adjust Specification
C2-2230
LG Electronics
by mode.
LGE LCD Division LG(51)
Establish:
Reform:
LC12E Adjust Specification
C2-2230
LG Electronics
6.1 Method
1) GND & Internal Pressure auto-check preparation
- Check that Power Cord is fully inserted to the SET.
(If loose, re-insert)
- Connect D-terminal to AV JACK TESTER
- Auto CONTROLLER(GWS103-4) ON
- Perform I/P test
- If NG, Buzzer will sound to inform the operator.
- If OK, Good lamp will lit up and the stopper will allow the pallet to move on to next process.