- 15 -
4.4.6.  Reference (White Balance Adj. coordinate and 
color temperature)
▪ Luminance: 204 Gray
▪  Standard  color  coordinate  and  temperature  using  CS-1000 
(over 26 inch)
Mode
Coordinate
Temp
uv
X
Y
Cool
0.269
0.273
13,000K
0.0000 
Medium
0.285
0.293
9,300K
0.0000 
Warm
0.313
0.329
6,500K
+0.0030  
▪  Standard color coordinate and temperature using CA-210(CH 18) - ALEF
Mode
Coordinate
Temp
uv
X
Y
Cool
0.269±0.002
0.273±0.002
13,000K
0.0000 
Medium
0.285±0.002
0.293±0.002
9,300K
0.0000 
Warm
0.313±0.002
0.329±0.002
6,500K
+0.0030  
▪ Standard color coordinate and temperature using CA-210(CH 14) - LGD
Mode
Coordinate
Temp
uv
X
Y
Cool
0.269±0.002
0.273±0.002
13,000K
0.0000 
Medium
0.285±0.002
0.293±0.002
9,300K
0.0000 
Warm
0.313±0.002
0.329±0.002
6,500K
0.0000 
4.4.6.1 ALELF&EDGE LED&IOL White balance table 
▪  Edge LED module change color coordinate because of aging time 
▪  apply under the color coordinate table, for compensated aging time
 Edge (LM860X)
GP4 Aging time
(Min)
Cool
Medium
Warm
X
Y
X
Y
X
Y
269
273
285
293
313
329
1
0-2
283
293
299
313
320
339
2
3-5
282
291
298
311
319
337
3
6-9
281
290
297
310
318
336
4
10-19
279
289
295
309
316
335
5
20-35
277
284
293
304
314
330
6
36-49
274
279
290
299
311
325
7
50-79
271
277
287
297
308
323
8
80-149
270
274
286
294
307
320
9
Over 150
269
273
285
293
306
319
4.4.7 THX Adjustment (For US Models)
For THX models, White Balance 4 point automatic control can 
be done through the below steps. (Warm axis)
(1) 100 IRE White Balance Adjustment done.
(2) Control Backlight so the Maximum brightness
*In  case  of  100  IRE  adjustment,  backlight  target  value  is 
125cd/m2.
(3) 4 Point gamma and W/B adjustment done.
* With  the  controlled  maximum  brightness,  adjust  the  Gamma 
2.2 (60, 40, and 20 IRE / do not adjust at 80 IRE)
*For 10 IRE, set R, G, B gain to 0, 0, and 0, respectively.
4.5. Option selection per country
4.5.1. Overview
(1)  Press ADJ  key  on  the Adj.  R/C,  and  then  select  Country 
Group Menu.
(2)  Depending  on  destination,  select  KR  or  US,  then  on  the 
lower Country option, select US, CA, MX. Selection is done 
using +, - KEY
4.6. Tool Option Inspection
▪ Method: Press Adj. key on the Adj. R/C, then select Tool option. 
Model
Tool 1 Tool 2 Tool 3 Tool 4 Tool 5 Tool 6 Tool 7
47LM8600-UC 32983 41026 30509 12333 23055 1324 62731
55LM8600-UC 32985 41026 30509 12333 23055 1323 62731
4.7. Local Dimming Inspection (Optional)
4.7.1. ALEF models with local dimming
(1)  Press  ‘TILT”  key  of  the  Adj.  R/C  and  check  moving 
patterns. The black bar patterns moves from top to bottom.
      If a local dimming function does not work, a whole screen 
shows full white
4.8. Ship-out mode check (In-stop)
▪  After final inspection, press In-Stop key of the Adj. R/C and 
check that the unit goes to Stand-by mode.
▪ After final inspection, Always turn on the Mechanical S/W.
4.9. WIFI MAC ADDRESS CHECK
a. Using RS232
Command
Set ACK
Transmission
[A][l][][Set ID][][20][Cr]
[O][K][x]  or  [N][G]
b. check the menu on in-start
Note that there are Wi-Fi MAC and MAC address.
Wi-Fi MAC is used for wireless network and MAC address is used 
for wired network
- 16 -
5.1. Method
   - Check that Power Cord is fully inserted to the SET.
     (If loose, re-insert)
    -  Unit  fully  inserted  Power  cord; Antenna  cable  and A/V 
arrive to the auto-check process. 
    - Connect D-terminal to AV JACK TESTER
    - Auto CONTROLLER (GWS103-4) ON
    - Perform GND TEST
    - If NG, Buzzer will sound to inform the operator.
    - If OK, changeover to I/P check automatically.
      (Remove CORD, A/V form AV JACK BOX)
    - Perform I/P test
    - If NG, Buzzer will sound to inform the operator.
    -  If OK, Good lamp will lit up and the stopper will allow the 
pallet to move on to next process.
5.2. Checkpoint
(1) Test voltage
    - GND: 1.5KV/min at 100mA
    - SIGNAL: 3KV/min at 100mA
(2) TEST time: 1 second
(3) TEST POINT
    -  GND  Test  =  POWER  CORD  GND  and  SIGNAL  CABLE 
GND.
    - Hi-pot Test = POWER CORD GND and LIVE & NEUTRAL.
(4) LEAKAGE CURRENT: At 0.5mArms
6. EYE-Q Operation check
Step 1) Turn on the TV..
Step 2)  Press  'EYE  button'  on  the  adjustment  remote-
controller.
Step 3)  Cover  'Eye  Q  sensor'  on  the  front  of  set  with  your 
hands, hold it for 6 seconds.
Step 4)  Check "the Sensor Data" on the screen, make certain 
that  Data  is  below  10.  If  Data  isn’t  below  10  in  6 
seconds,  Eye  Q  sensor  would  be  bad.  You  should 
change Eye Q sensor.
Step 5)  Uncover  your hands  from Eye Q sensor, hold  it for 6 
seconds.
Step 6)  Check  "Back  Light(xxx)"  on  the  screen,  check  data 
increase . You should change Eye Q sensor. 
7. Magic Motion Remote Control Inspection  
-  Required  Instruments:  Inspection  RF-remote  control, 
Inspection IR-KEY-CODE remote control.
-  Prior to the test, AA battery for the RF-remote control should 
be adequate.
  (Change the battery for each LOT is recommended)
- Test procedures
(1) Press the ‘START’ key on the controller to pair with the set.
(2)  Press the ‘OK’ key in the controller and check whether the 
cursor appears on the set.
(3) Press ‘Vol+ (STOP)’ key to de-pair with the set. 
8. 3D function test 
 
8.1 Test equipment
(1)  Pattern  Generator  MSHG-600  or  MSPG-6100  (HDMI  1.4 
support)
(2) Pattern: HDMI mode (model No. 872, pattern No. 83)
8.2 Test method
(1) Input 3D test signal as Fig.1.
(2) Press ‘OK” key as a 3D input OSD is shown.
(3)  Check  pattern  as  Fig2  without  3D  glasses.  (3D  mode 
without 3D glasses)
Fig.2
<OK in 3D mode without 3D glasses>
 
<Step 2>
<Step 5>
<Step 6>
<Step 3>
<Step 4>
- 17 -
9. HDMI ARC Function Inspection
 
9.1. Test equipment
- Optic Receiver Speaker          
- MSHG-600 (SW: 1220 ↑) 
- HDMI Cable (for 1.4 version)
9.2 Test method
(1)  Insert  the  HDMI  Cable  to  the  HDMI ARC  port  from  the 
master equipment (HDMI1)
(2) Check the sound from the TV Set
(3)  Check  the  Sound  from  the  Speaker  or  using AV  &  Optic 
TEST program (It’s connected to MSHG-600)
* Remark:  Inspect in Power Only Mode and check SW version 
in a master equipment
.
10. USB S/W Download 
    (optional, Service only)
(1) Put the USB Stick to the USB socket 
(2) Automatically detecting update file in USB Stick
  -  If  your  downloaded  program  version  in  USB  Stick  is  lower 
than  that  of TV  set,  it  didn’t  work.  Otherwise  USB  data  is 
automatically detected.
(3) Show the message “Copying files from memory”
(5) Updating Completed, The TV will restart automatically
(6)  If  your TV  is  turned  on,  check  your  updated  version  and 
Tool option. 
*  If downloading version is more high than your TV have, TV 
can lost all channel data. In this case, you have to channel 
recover. If all channel data is cleared, you didn’t have a DTV/
ATV test on production line.
* After downloading, TOOL OPTION setting is needed again.
(1) Push "IN-START" key in service remote controller.
(2) Select "Tool Option 1" and Push “OK” button.
(3) Punch in the number. (Each model has their number.)
(5) Updating Completed, The TV will restart automatically
(6)  If  your TV  is  turned  on,  check  your  updated  version  and 
Tool option. 
*  If downloading version is more high than your TV have, TV 
can lost all channel data. In this case, you have to channel 
recover. If all channel data is cleared, you didn’t have a DTV/
ATV test on production line.
* After downloading, TOOL OPTION setting is needed again.
(1) Push "IN-START" key in service remote controller.
(2) Select "Tool Option 1" and Push “OK” button.
(3) Punch in the number. (Each model has their number.)
(4) Updating is staring.
- 18 -
EXPLODED VIEW
Many electrical and mechanical parts in this chassis have special safety-related characteristics. These 
parts are identified by       in the Schematic Diagram and EXPLODED VIEW. 
It  is  essential  that  these  special  safety  parts  should  be  replaced  with  the  same  components  as 
recommended in this manual to prevent X-RADIATION, Shock, Fire, or other Hazards. 
Do not modify the original design without permission of manufacturer.
IMPORTANT SAFETY NOTICE
A22
A10
AG
1
* Set + Stand * Stand Base + Body
900
300
301
200
400
700
710
540
521
530
800
810
541
910
560
410
570
120
510
501
500
580
310
LV
1
123
122
Page of 111
Display

Click on the first or last page to see other 47LM8600 / 47LM8650 (CHASSIS:LA23E) service manuals if exist.