DOWNLOAD LG 47LH30 (CHASSIS:LA92A) Service Manual ↓ Size: 5.1 MB | Pages: 34 in PDF or view online for FREE

Model
47LH30 (CHASSIS:LA92A)
Pages
34
Size
5.1 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD
File
47lh30-chassis-la92a.pdf
Date

LG 47LH30 (CHASSIS:LA92A) Service Manual ▷ View online

- 13 -
LG Electronics. Inc. All right reserved. 
C
2009
12. POWER 
No
Item
Min Typ
Max 
Unit 
Remark
1.
Power On/Off 
10000
times
2.
DC Voltage
Inverter Voltage 
21.6 
24 
26.4 
V
Logic Voltage(Vcc)
4.7 
5
5.3 
V
Sound Amp Vcc 
14.0
15.0 
16.0 
14~25V
19
20
21
V
20V: Lips
23
24
25
V
24V: Normal PSU
Micom B+
3.25
3.4
3.55
V
Tuner           5V
4.75 
5.0 
5.25 
V
VSC Vcc  
24V
23.0
24.0
22.0
V
Normal PSU
20V
19.0
20.0
21.0
V
Lips 
12V
11.0 12.0 13.0  V
5V
4.5
5.0
5.5 
V
Inside Temp.Under 20deg. 
No operation 
0.5 
3.
AC Power Shut Down Voltage 
90 
264 
V
Wide Range PSU
13. Mechanical Specification.
No
Item
Content
Unit
Protrusion
Satisfy appearance inspection 
LG(51)G2-2001
Appearance quality 
Satisfy appearance inspection 
LG(51)G1-1030
Print specification 
Distinguish printed matter at a distance of 40cm
Product 
Before Packing
1140.6 (W)X 723 (H)X 99 (D)
mm
Without Stand
Dimension 
After Packing
1250 (W)X 885 (H)X 245 (D)
mm
Without Stand
Product 
Only SET 
21.9 
Kg
Without Stand
Weight
With BOX 
24.5
Kg
Without Stand
6 Stand 
Ass’y SWIVEL
(±)20
degree
Fixed 
Stand
11. DIGITAL PART
No Item  Standard 
Unit
Remark
1.
VSB Receiving 
CH.2 ~69CH
1 ~135CH(CATV)
1 ~135CH(CADTV))
2.
Video Resolution 
ATSC 18 FORMAT
3.
Audio Bit Resolution
32,40,48,56,64,80,96,112,128,160,
Kbps
192,224,256,320,384,448,512,576,640
4.
VSB RF Input
75
unbalanced, F type Connector input
5.
Sync Stable Time 
Under 3.0 
SEC
LG Electronics. Inc. All right reserved. 
C
2009
- 14 -
ADJUSTMENT INSTRUCTION
1. Application range
This spec. sheet applies to LA92A Chassis applied LCD TV all
models manufactured in TV factory
2.Specification
1) Because this is not a hot chassis, it is not necessary to use an
isolation transformer.However, the use of isolation
transformer will help protect test instrument.
2) Adjustment must be done in the correct order.
3) The adjustment must be performed in the circumstance of 25
±50ºC of temperature and 65±10% of relative humidity if there
is no specific designation.
4) The input voltage of the receiver must keep 100~240V,
50/60Hz. 
5) The receiver must be operated for about 5 minutes prior to the
adjustment when module is in the circumstance of over 15°C
- In case of keeping module is in the circumstance of 0°C, it
should be placed in the circumstance of above 15°C for 2 hours.
- In case of keeping module is in the circumstance of below -
20°C, it should be placed in the circumstance of above 15°C
for 3 hours.
*Caution) When still image is displayed for a period of 20
minutes or longer (especially where W/B scale is strong.
Digital pattern 13ch and/or Cross hatch pattern 09ch), there
can some afterimage in the black level area.
3. Adjustment items 
1) Main PCB check process
• Adjust 480i Comp1
• Adjust 1024*768 RGB
Above adjustment items can be also performed in Final
Assembly if needed. Both Board-level and Final assembly
adjustment items can be check using In-Star Menu
1)ADJUST CHECK.
2)  Final assembly adjustment
• EDID/DDC download
• White Balance adjustment
• RS-232C functionality check
• Factory Option setting per destination
• Ship-out mode setting (In-Stop)
3) Etc
• Ship-out mode
• Service Option Default
• USB Download(S/W Update, Option, Service only)
• ISP Download(Option)
4. Automatic Adjustment
4.1 ADC Adjustment
4.1.1 Overview
ADC adjustment is needed to find the optimum black level and
gain in Analog-to-Digital device and to compensate RGB
deviation. 
4.1.2 Equipment & Condition
1) Jig (RS-232C protocol)
2) MSPG-925 Series Pattern Generator(MSPG-925FA)
- Resolution: 480i Comp1(MSPG-925FA model-209, pattern-65)
1024*768 RGB (MSPG-925FA: model-60 , pattern-65)
- Pattern : Horizontal 100% Color Bar Pattern
- Pattern level : 0.7±0.1 Vp-p
4.1.3 Adjustment
4.1.3.1 Adjustment method
• Using RS-232, adjust items listed in 3.1 in the other shown
in “4.1.3.3”
4.1.3.2 Adj. protocol 
Ref.) ADC Adj. RS232C Protocol_Ver1.0
4.1.3.3 Adj. order
• ad 00 00 [Enter ADC adj. mode]
• xb 00 40 [Change input source to Component1(480i)]
• ad 00 10 [Adjust 480i Comp1]
• xb 00 60 [Change input source to RGB(1024*768)]
• ad 00 10 [Adjust 1024*768 RGB]
• ad 00 90 End adj.
Ref) ADC adj. RS232C Protocol_Ver1.0
Protocol     Command 
Set ACK
Enter mode
aa 00 00  d 00 OK00x
Source 
xb 00 40
b 00 OK40x (Adjust 480i Comp1 )
change 
xb 00 60b  00 OK60x (Adjust 1024*768 RGB)
Begin adj. 
ad 00 10
Return 
OKx (Case of Success)
adj. result
NGx (Case of Fail)
Read
(main) (main 
)
adj. data
ad0020 
0000000000000000000000007c007b006dx
(sub ) 
(Sub)
ad 00 21   000000070000000000000000007c00830077x
Confirm adj.  ad 00 99  NG 03 00x (Fail)
NG 03 01x (Fail)
NG 03 02x (Fail)
OK 03 03x (Success)
End adj. 
ad 00 90  d 00 OK90x
5.Manual Adjustment
5.1 ADC(Saturn5) Adjustment
5.1.1 Overview
ADC adjustment is needed to find the optimum black level and
gain in Analog-to-Digital device and to compensate RGB
deviation.
5.1.2 Equipment & Condition
1) Adjust Remocon
2) 801GF(802B, 802F, 802R) or MSPG925FA Pattern Generator
- Resolution: 480i, 1024*768
- Pattern : Horizontal 100% Color Bar Pattern
- Pattern level: 0.7±0.1 Vp-p
3) Must use standard cable
5.1.3 Adjust method
5.1.3.1 ADC 480i Comp1
1) Check connected condition of Comp1 cable to the
equipment
2) Give a 480i Mode, Horizontal 100% Color Bar Pattern to
Comp1.(MSPG-925FA Î Model: 209, Pattern: 65)
3) Change input mode as Component1 and picture mode as
“Standard”
4) Press the In-start Key on the ADJ remote after at least 1
min of signal reception. Then, select  7. External ADC -> 1.
COMP 480i on the menu. Press enter key. The adjustment
will start automatically.
5) If ADC calibration is successful, “ADC RGB Success” is
displayed. 
If ADC calibration is failure, “ADC RGB Fail” is displayed.
6) If ADC calibration is failure, after recheck ADC pattern or
condition retry calibrationError message refer to
5.2 White Balance Adjustment
5.2.1 Overview
• W/B adj. Objective & How-it-works
- Objective: To reduce each Panel’s W/B deviation
- How-it-works: When R/G/B gain in the OSD is at 192, it
means the panel is at its Full Dynamic Range. In order to
prevent saturation of Full Dynamic range and data, one of
R/G/B is fixed at 192, and the other two is lowered to find
the desired value.
- Adj. condition : normal temperature
1) Surrounding Temperature: 25±5 °C
2) Warm-up time: About 5 Min
3) Surrounding Humidity: 20% ~ 80%
5.2.2 Equipment
1) Color Analyzer : CA-210 (NCG: CH 9 / WCG: CH12 /LED
Module:CH14)
2) Adj. Computer (During auto adj., RS-232C protocol is
needed)
3) Adjust Remocon
4) 
Video Signal Generator MSPG-925F 720p/216-
Gray(Model:217, Pattern:78)
-> Only when internal pattern is not available 
• Color Analyzer Matrix should be calibrated using CS-1000
5.2.3 Equipment connection MAP
5.2.4 Adj.Command (Protocol)
• RS-232C Command used during auto-adj. 
Ex) wb 00 00 -> Begin white balance auto-adj.
wb 00 10 -> Gain adj.
ja 00 ff -> Adj. data
jb 00 c0
... 
...
wb 00 1f -> Gain Gain adj. complete
*(wb 00 20(Start), wb 00 2f(End)) -> Off-set adj. 
wb 00 ff -> End white balance auto adj.  
5.2.5 Adj. method
5.2.5.1 Auto adj. method
1) Set TV in adj. mode using POWER ON key
2) Zero calibrate probe then place it on the center of the
Display
3) Connect Cable(RS-232C)
4) Select mode in adj. Program and begin adj.
5) When adj. is complete (OK Sing), check adj. status pre
mode (Warm, Medium, Cool)
6) Remove probe and RS-232C cable to complete adj.
• W/B Adj. must begin as start command “wb 00 00” , and finish
as end command “wb 00 ff”, and Adj. offset if need
- 15 -
LG Electronics. Inc. All right reserved. 
C
2009
Color Analyzer
Computer
RS-232C
# Pattern Generator
Signal Source
Probe
RS-232C
RS-232C
* If TV internal patter n is used, not  
CMD
ID DATA
Explanation
wb 
00 
00 
Begin White Balance adj.
wb
00 
ff
End White Balance adj.
(internal pattern disappears )
5.2.5.2 Manual adj. method
1) Set TV in Adj. mode using POWER ON
2) Zero Calibrate the probe of Color Analyzer, then place it on
the center of LCD module within10cm of the surface..
3) Press ADJ key -> EZ adjust using adj. R/C Æ 6. White-
Balance then press the cursor to theright (KEY
).
(When KEY(
) is pressed 216 Gray internal pattern will be
displayed)
4) One of R Gain / G Gain / B Gain should be fixed at 192,
and the rest will be lowered to meet the desired value.
5) Adj. is performed in COOL, MEDIUM, WARM 3 modes of
color temperature.
• If internal pattern is not available, use RF input. In EZ Adj.
menu 6.White Balance, you can select one of 2 Test-pattern:
ON, OFF. Default is inner(ON). By selecting OFF, you can
adjust using RF signal in 216 Gray pattern.
• Adj. condition and cautionary items
1) Lighting condition in surrounding area Surrounding lighting
should be lower 10 lux. Try to isolate adj. area into dark
surrounding.
2) Probe location
- PDP: Color Analyzer (CA-100, CA-100+, CA210) probe
should be firmly attached to the Module
- LCD: Color Analyzer (CA-210) probe should be within 10cm
and perpendicular of the module surface (80°~ 100°)
3) Aging time
- After Aging Start, Keep the Power ON status during 5
Minutes.
- In case of LCD, Back-light on should be checked using no
signal or Full-white pattern.
5.2.6 Reference (White Balance Adj. coordinate and color
temperature)
• Luminance: 216 Gray
• Standard color coordinate and temperature using CS-1000
(over 26 inch)       
• Standard color coordinate and temperature using CA-210(CH 9)
5.3 Option selection per country 
1) Press ADJ key on the Adj. R/C, then select Country Group
Meun.
2) Depending on destination, select KR, then on the lower
Country option. Selection is done using +, - KEY
6. USB S/W Download(option)
1. Put the USB Stick to the USB socket
2. Automatically detecting update file in USB Stick
- If your downloaded program version in USB Stick is Low, it
didn’t work. But your downloaded version is High, USB data is
automatically detecting
3. Show the message “Copying files from memory”
4. Updating is staring.
5. Updating Completed, The TV will restart automatically
6. If your TV is turned on, check your updated version and
Tool option. (explain the Tool option, next stage)
* If downloading version is more high than your TV have, TV
can lost all channel data. In this case, you have to channel
recover. if all channel data is cleared, you didn’t have a
DTV/ATV test on production line.
* After downloading, have to adjust TOOL OPTION again.
1. Push "IN-START" key in service remote controller.
2. Select "Tool Option 1" and Push “OK” button.
3. Punch in the number. (Each model has their number.)
- 16 -
LG Electronics. Inc. All right reserved. 
C
2009
Coordinate 
Mode 
x y 
Temp uv
Cool 0.276 0.283  11000K  0.0000
Medium 0.285  0.293 
9300K 
0.0000
Warm 0.313  0.329 
6500K  0.0000
Coordinate 
Mode 
x y 
Temp uv
Cool 0.276±0.002 0.283±0.002 11000K 0.0000
Medium 0.285±0.002  0.293±0.002 
9300K 
0.0000
Warm 0.313±0.002  0.329±0.002  6500K  0.0000
Model    Tool1   Tool2  Tool3 Tool4
Menu
47LH30  32897   2600   932    1152   3 HDMI,CAN Tuner,1 RCA
 
 
 
 
 
Page of 34
Display

Click on the first or last page to see other 47LH30 (CHASSIS:LA92A) service manuals if exist.