DOWNLOAD LG 47LD450 / 47LD450N / 47LD458 (CHASSIS:LD01B) Service Manual ↓ Size: 5.22 MB | Pages: 43 in PDF or view online for FREE

Model
47LD450 47LD450N 47LD458 (CHASSIS:LD01B)
Pages
43
Size
5.22 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD
File
47ld450-47ld450n-47ld458-chassis-ld01b.pdf
Date

LG 47LD450 / 47LD450N / 47LD458 (CHASSIS:LD01B) Service Manual ▷ View online

4) Updating is staring.
5) Uploading completed, The TV will restart automatically.
6) If your TV is turned on, check your updated version and
Tool option.(explain the Tool option, next stage)
* If downloading version is more high than your TV have,
TV can lost all channel data. In this case, you have to
channel recover. if all channel data is cleared, you didn’t
have a DTV/ATV test on production line.
* After downloading, have to adjust Tool Option again.
1) Push "IN-START" key in service remote controller 
2) Select “Tool Option 1” and Push “OK” button.
3) Punch in the number. (Each model hax their number)
4) Completed selecting Tool option.
3.1. ADC Process
(1) ADC
G
” key at “5. ADC
Calibration”
<Caution> Using  ‘power on’ button of the Adjustment R/C,
power on TV.
* ADC Calibration Protocol (RS232)
Adjust Sequence
• aa 00 00 [Enter Adjust Mode]
• xb 00 40 [Component1 Input (480i)]
• ad 00 10 [Adjust 480i Comp1]
• xb 00 60 [RGB Input (1024*768)]
• ad 00 10 [Adjust 1024*768 RGB]
• aa 00 90 End Adjust mode
* Required equipment : Adjustment R/C.
3.2. Function Check
* Check display and sound
- Check Input and Signal items. (cf. work instructions)
1) TV
2) AV (SCART1/SCART2/ CVBS)
3) COMPONENT (480i)
4) RGB (PC : 1024 x 768 @ 60hz)
5) HDMI
6) PC Audio In
* Display and Sound check is executed by Remote control.
- 10 -
Module
Tool option1 Tool option2 Tool option3 Tool option4 Tool option5
LGD
32801
10800
36868
26893
0
CMO
32805
10800
36868
26893
0
Item CMD1 CMD2 
 
Data0
Adjust ‘Mode In’
A
A
0
0 When transfer the ‘Mode In’,
Carry the command.
ADC Adjust
D
1
0 Automatically adjustment
(The use of a internal pattern)
4. Total Assembly line process
4.1. Adjustment Preparation
· W/B Equipment condition
CA210 : CH 9, Test signal : Inner pattern (85IRE)
· Above 5 minutes H/run in the inner pattern. (“power on” key
of adjust remote control)
* Connecting picture of the measuring instrument
(On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push Adjustment R/C POWER ON ->
Enter the mode of White-Balance, the pattern will come out.
* Auto-control interface and directions
1) Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10 lux).
2) Adhere closely the Color Analyzer (CA210) to the module
less than 10 cm distance, keep it with the surface of the
Module and Color Analyzer’s prove vertically.(80° ~ 100°).
3) Aging time
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 5 minutes.
- Using ‘no signal’ or ‘full white pattern’ or the others,
check the back light on.
• Auto adjustment Map(RS-232C)
RS-232C COMMAND
[CMD
ID DATA]
Wb
00
00
White Balance Start
Wb
00
ff
White Balance End
** Caution **
Color Temperature : COOL, Medium, Warm. 
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and
adjust other two lower than C0.
(when R/G/B Gain are all C0, it is the FULL Dynamic Range
of Module)
* Manual W/B process using adjusts Remote control.
• After enter Service Mode by pushing “ADJ” key,
• Enter White Balance by pushing “
G
” key at “6. White
Balance”.
* After done all adjustments, Press “In-start” button and
compare Tool option and Area option value with its BOM, if
it is correctly same then unplug the AC cable. If it is not
same, then correct it same with BOM and unplug AC cable.
For correct it to the model’s module from factory JIG model.
* Push the “IN STOP” key after completing the function
inspection. And Mechanical Power Switch must be set
“ON”.
4.2. DDC EDID Write (RGB 128Byte )
• Connect D-sub Signal Cable to D-sub Jack.
• Write EDID Data to EEPROM(24C02) by using DDC2B
protocol.
• Check whether written EDID data is correct or not.
* For SVC main Assembly, EDID have to be downloaded to
Insert Process in advance.
4.3. DDC EDID Write (HDMI 256Byte)
• Connect HDMI Signal Cable to HDMI Jack.
• Write EDID Data to EEPROM(24C02) by using DDC2B
protocol.
• Check whether written EDID data is correct or not.
* For SVC main Assembly, EDID have to be downloaded to
Insert Process in advance.
4.4. EDID DATA
1) All Data : HEXA Value
2) Changeable Data :
*: Serial No : Controlled / Data:01
**: Month : Controlled / Data:00
***:Year : Controlled
****:Check sum
- 11 -
Cool 13,000
K
X=0.269(±0.002)
Y=0.273(±0.002)
<Test Signal>
Medium
9,300
K
X=0.285(±0.002)
Inner pattern
Y=0.293(±0.002)
(216gray,85IRE)
Warm
6,500
K
X=0.313(±0.002)
Y=0.329(±0.002)
 
Full White Pattern
COLOR
ANALYZER
TYPE: CA-210
RS-232C Communication
CA-210
RS-232C COMMAND MIN
CENTER
MAX
[CMD ID DATA]
(DEFAULT)
Cool
Mid
Warm
Cool
Mid
Warm
R Gain
jg 
Ja 
jd 
00
172 
192 
192
192
G Gain 
jh 
Jb
je 
00
172 
192 
192
192
B Gain 
ji 
Jc 
jf
00
192 
192 
172 
192
R Cut 
64 
64 
64 
128
G Cut 
64 
64 
64 
128
B Cut 
64 
64 
64 
128
- Auto Download
• After enter Service Mode by pushing “ADJ” key,
• Enter EDID D/L mode.
• Enter “START” by pushing “OK” key.
* Edid data and Model option download (RS232)
- Manual Download
* Caution
1) Use the proper signal cable for EDID Download
- Analog EDID : Pin3 exists
- Digital EDID : Pin3 exists
2) Never connect HDMI & D-sub Cable at the same time.
3) Use the proper cables below for EDID Writing
4) Download HDMI1, HDMI2, separately because HDMI1 is
different from HDMI2
1) FHD RGB EDID data
2) FHD HDMI EDID data
* Detail EDID Options are below
ⓐ Product ID
ⓑ Serial No: Controlled on production line.
ⓒ Month, Year: Controlled on production line:
ex) Monthly : ‘02’ -> ‘02’
Year : ‘2009’ -> ‘13’
ⓓ Model Name(Hex):
ⓔ Checksum: Changeable by total EDID data.
ⓕ Vendor Specific(HDMI)
Model Name
HEX
EDID Table
DDC Function
FHD Model
0001
01 00
Analog/Digital
- 12 -
MODEL
MODEL NAME(HEX)
all
00 00 00 FC 00 4C 47 20 54 56 0A 20 20 20 20 20 20 20
Item CMD1 CMD2 Data0
Download
A
A
0
0
When transfer the ‘Mode In’,
‘Mode In’
Carry the command.
Download
A
E
00 10 Automatically Download
(The use of a internal pattern)
Item
Manufacturer ID
Version
Revision
Condition
GSM
Digital : 1
Digital : 3
Data(Hex)
1E6D
01
03
D-sub to D-sub
DVI-D to HDMI or HDMI to HDMI
For HDMI EDID
For Analog EDID
INPUT
MODEL NAME(HEX)
HDMI1 67030C001000B82D
HDMI2 67030C002000B82D
HDMI3 67030C003000B82D
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
00
00
FF
FF
FF
FF
FF
FF
00
1E
6D
10
01
03
68
73
41
78
0A
CF
74
A3
57
4C
B0
23
20
09
48
4C
A1
08
00
81
80
61
40
45
40
31
40
01
01
30
01
01
01
01
01
01
02
3A
80
18
71
38
2D
40
58
2C
40
45
00
7E
8A
42
00
00
1E
01
1D
00
72
51
D0
1E
20
50
6E
28
55
00
7E
8A
42
00
00
1E
00
00
00
FD
00
3A
60
3E
1E
53
10
00
0A
20
20
20
20
20
20
70
00
80
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
90
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
A0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
B0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
C0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
D0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
E0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
F0
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
00
00
FF
FF
FF
FF
FF
FF
00
1E
6D
10
01
03
80
73
41
78
0A
CF
74
A3
57
4C
B0
23
20
09
48
4C
A1
08
00
81
80
61
40
45
40
31
40
01
01
30
01
01
01
01
01
01
02
3A
80
18
71
38
2D
40
58
2C
40
45
00
7E
8A
42
00
00
1E
01
1D
00
72
51
D0
1E
20
50
6E
28
55
00
7E
8A
42
00
00
1E
00
00
00
FD
00
3A
60
3E
1E
53
10
00
0A
20
20
20
20
20
20
70
01
80
02
03
26
F1
4E
10
1F
84
13
05
14
03
02
12
20
21
90
22
15
01
26
15
07
50
09
57
07
A0
E3
05
03
01
01
1D
80
18
71
1C
16
20
58
2C
B0
25
00
7E
8A
42
00
00
9E
01
1D
00
80
51
D0
0C
20
C0
40
80
35
00
7E
8A
42
00
00
1E
02
3A
80
18
71
38
D0
2D
40
58
2C
45
00
7E
8A
42
00
00
1E
66
21
50
B0
E0
51
00
1B
30
40
70
36
00
7E
8A
42
00
00
1E
00
00
F0
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
F9
- 13 -
4.5. V-COM Adjust(Only LGD(M+S) Module)
- Why need Vcom adjustment?
A
The Vcom (Common Voltage) is a Reference Voltage of
Liquid Crystal Driving.
-> Liquid Crystal need for Polarity Change with every frame.
- Adjust sequence
· Press the PIP key of th ADJ remote control.(This PIP key is
hot key to enter the VCOM adjusting mode)
(Or After enter Service Mode by pushing “ADJ” key, then
Enter V-Com Adjust mode by pushing “
G
” key at “10. V-
Com”
· As pushing the right or the left key on the remote control,
and find the V-COM value which is no or minimized the
Flicker. (If there is no flicker at default value, Press the exit
key and finish the VCOM adjustment.)
· Push the “OK” key to store value. Then the message
“Saving OK” is pop.
· Press the exit key to finish VCOM adjustment.
(Visual Adjust and control the Voltage level)
4.6. Outgoing condition Configuration
- When pressing IN-STOP key by SVC remocon, Red LED are
blinked alternatively. And then Automatically turn off.
(Must not AC power OFF during blinking)
Confirm whether is normal or not when between power
board’s ac block and GND is impacted on 1.5 kV(dc) or 2.2
kV(dc) for one second.
5. Model name & Serial number D/L
• Press “Power on” key of service remocon.
(Baud rate : 115200 bps)
• Connect RS232 Signal Cable to RS-232 Jack.
• Write Serial number by use RS-232.
• Must check the serial number at the Diagnostics of SET UP
menu. (Refer to below).
5.1. Signal TABLE
CMD : A0h
LENGTH : 85~94h (1~16 bytes)
ADH : EEPROM Sub Address high (00~1F)
ADL : EEPROM Sub Address low (00~FF)
Data : Write data
CS : CMD + LENGTH + ADH + ADL + Data_1 +…+ Data_n
Delay : 20ms
5.2. Command Set
* Description
FOS Default write : <7mode data> write
Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0,
Phase
Data write : Model Name and Serial Number write in
EEPROM,.
5.3. Method & notice
A. Serial number D/L is using of scan equipment.
B. Setting of scan equipment operated by Manufacturing
Technology Group.
C. Serial number D/L must be conformed when it is produced
in production line, because serial number D/L is mandatory
by D-book 4.0.
CMD 
LENGTH
ADH 
ADL 
DATA_1
. . . 
Data_n 
CS 
DELAY 
No. Adjust 
mode 
CMD(hex)
LENGTH(hex) 
Description 
EEPROM WRITE 
A0h 
84h+n 
n-bytes Write (n = 1~16) 
Row  Li ne
Column  Line
C
LC
C
ST
Pane l
S
Y
S
T
E
M
Gat
e
 Driv
e
 IC
So urce D r i v e  I C
Circuit Block
Ti m i n g  
Co nt r o ll e r
Po w e r  
Blo ck
V
COM
Ga mma
Re f e r e nce V o ltage
Gamm a R eference
Volta ge
Da ta (R ,G,B ) & C ont ro l s ignal
Con t rol si gnal
Data (R ,G,B ) &
Con t rol si gnal
In
te
r
fa
c
e
TFT
Po w e r  I n p u t
Power Input
Da t a  I n p u t
Da t a  I n p u t
V
COM
Liquid 
Crys tal
V
COM
Page of 43
Display

Click on the first or last page to see other 47LD450 / 47LD450N / 47LD458 (CHASSIS:LD01B) service manuals if exist.