DOWNLOAD LG 42SL90QD-DA (CHASSIS:LT91L) Service Manual ↓ Size: 4.5 MB | Pages: 69 in PDF or view online for FREE

Model
42SL90QD-DA (CHASSIS:LT91L)
Pages
69
Size
4.5 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD
File
42sl90qd-da-chassis-lt91l.pdf
Date

LG 42SL90QD-DA (CHASSIS:LT91L) Service Manual ▷ View online

- 10 -
No
Resolution
H-freq(kHz)
V-freq.(Hz)
Pixel clock(MHz)
Proposed
Remark
1.
720*400 31.468 
70.08 
28.321 
HDCP
2.
640*480 31.469 
59.94 
25.17
VESA  HDCP
3. 800*600
37.879
60.31 
40.00 
VESA 
HDCP
4.
1024*768
48.363
60.00 65.00 
VESA(XGA)
HDCP
5.
1280*768 47.78
59.87
79.5
WXGA  HDCP
6.
1360*768 47.72 59.8 84.75
WXGA  HDCP
7.
1280*1024 63.595
60.0  108.875  SXGA
HDCP
8.
1920*1080
67.5
60
148.5
WUXGA
HDCP
9.2.  PC Mode
9. HDMI Input (PC/DTV)
9.1. DTV Mode
No
Resolution
H-freq(kHz)
V-freq.(Hz)
Pixel clock(MHz)
Proposed
Remark
1.
720*480 
31.469 /31.5 
59.94 / 60
27.00/27.03
SDTV 480P
2.
720*576 31.25 
50
54 
SDTV 
576P
3.
1280*720 37.500 
50
74.25 
HDTV 
720P
4.
1280*720 
44.96 / 45 
59.94 / 60
74.17/ 74.25 
HDTV 720P
5.
1920*1080 
33.72 / 33.75 
59.94 / 60
74.17/ 74.25 
HDTV 1080I 
6.
1920*1080 28.125 50.00
74.25 
HDTV 
1080I
7.
1920*1080 
26.97 / 27 
23.97 / 24
74.17/ 74.25 
HDTV 1080P
8.
1920*1080
33.716 / 33.75
29.976 / 30.00
74.25
HDTV 1080P
9.
1920*1080 56.250 50
148.5
HDTV 
1080P
10.
1920*1080 
67.43 / 67.5 
59.94 / 60
148.35/148.50 
HDTV 1080P
- 11 -
ADJUSTMENT INSTRUCTION
1. Application Range
This specification sheet is applied to all of the LCD TV with
LT91T chassis.
2. Designation
1) The adjustment is according to the order which is
designated and which must be followed, according to the
plan which can be changed only on agreeing.
2) Power Adjustment: Free Voltage
3) Magnetic Field Condition: Nil.
4) Input signal Unit: Product Specification Standard
5) Reserve after operation: Above 5 Minutes (Heat Run)
Temperature : at 25±5ºC 
Relative humidity : 65±10%
Input voltage : 220V, 60Hz
6) Adjustment equipments: Color Analyzer (CA-210 or CA-
110), Pattern Generator(MSPG-925L or Equivalent), DDC
Adjustment Jig equipment, SVC remote controller
7) Push The “IN STOP KEY” - For memory initialization.
3. Main PCB check process
* APC - After Manual-Insert, executing APC
* Boot file Download
(1) Execute ISP program “Mstar ISP Utility” and then click
“Config” tab.
(2) Set as below, and then click “Auto Detect” and check “OK”
message.
If  “Error” is displayed, Check connection between
computer, jig, and set..
(3) Click  “Read” tab, and then load download file (XXXX.bin)
by clicking “Read”.
(4) Click  “Connect” tab. If “Can’t” is displayed, check
connection between computer, jig, and set.
(5) Click “Auto” tab and set as below
(6) Click “Run”.
(7) After downloading, check “OK” message.
          filexxx.bin 
(7) 
(5) 
(8) ……….OK 
(6) 
(1) 
(3) 
(2)
OK
Please Check the Speed : 
To use speed between 
from 200KHz to 400KHz 
(4) 
filexxx.bin 
Case1 : Software version up
1. After downloading S/W by USB, TV set will reboot
automatically
2. Push “In-stop” key
3. Push “Power on” key
4. Function inspection
5. After function inspection, Push “I n-stop” key.
Case2 : Function check at the assembly line
1. When TV set is entering on the assembly line, Push
“In-stop” key at first.
2. Push “Power on” key for turning it on.
-> If you push “Power on” key, TV set will recover
channel information by itself.
3. After function inspection, Push “In-stop” key.
* USB DOWNLOAD(*.epk file download)
(1) Put the USB Stick to the USB socket.
(2) Automatically detecting update file in USB Stick.
- If your downloaded program version in USB Stick is Low,
it didn’t work. But your downloaded version is High, USB
data is automatically detecting
(3) Show the message “Copying files from memory”
(4) Updating is staring.
(5) After updating is complete, The TV will restart automatically.
(6) If  TV  turns on, check your updated version and Tool
option. (refer to the next page about tool option)
* If downloading version is higher than your TV have, TV
can lost all channel data. In this case, you have to
channel recover. If all channel data is cleared, you didn’t
have a DTV/ATV test on production line.
* After downloading, have to adjust Tool Option again.
1. Push "IN-START" key in service remote controller.
2. Select "Tool Option 1" and Push “OK” button.
3. Punch in the number. (Each model has their number.)
4. Completed selecting Tool option.
3.1. ADC Process
• Input signal : Component 
• Signal equipment displays
Adjustment pattern
- Component 480I
MODEL: 209 in Pattern Generator(480i Mode)
PATTERN : 65 in Pattern Generator(MSPG-925 SERIES)
• Input Signal : RGB  (You  don’t need to connect RGB Cable).
Because We use TV internal pattern.
G
” key at “5. ADC
Calibration”
* Caution: Using ‘power on’ button of the Adj. R/C, power on TV.
* ADC Calibration Protocol (RS232)
* Adjustment can be done using only external ADC
* Required equipment : Adjustment R/C.
* Down Load data of picture
This process must do in using the LED model
- Push the button “Power Only “ key in Adjust remote control
- Push the button “ Exit” key in Adjust remote control
3.2. Function Check
(1) Check display and sound
- Check Input and Signal items. (cf. work instructions)
1) TV
2) AV (CVBS)
3) COMPONENT (480i)
4) RGB (PC : 1024 x 768 @ 60hz)
5) HDMI 
6) PC Audio In 
* Display and sound check is executed by remote control.
- 12 -
Model 
Tool option1  Tool option2 Tool option3  Tool option4
47SL80YD
34305
3144
55974
4368
 
 
i
TV Software Upgrade
Upgrading...
Do not plug off!
63%
 
 
 
 
 
i
TV Software Upgrade
Upgrading COMPLETED
The TV will restart after    seconds.
100%
EZ ADJUT
0. Tool Option1  
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Country Group
5. ADC Calibration
6. White Balance
7. Test Pattern
8. EDID D/L
9. Sub B/C
ADC Calibration
ADC Comp 480i
ADC Comp 1080p
ADC RGB
NG
NG
NG
Reset
Start
 
 
i
TV Software Upgrade
Copying files from memory
Do not remove the memory card from the pc
Do not plug off!
No.
Item
CMD1
CMD2
Data0
Data1
Main total mode 
0
0
0
0
Change to Component 
0
0
4
0
3 Adjust 
Component 
0
0
1
0
Change to RGB 
0
0
6
0
5 Adjust 
RGB 
0
0
1
0
4. Total Assembly line process
4.1. Adjustment Preparation
· W/B Equipment condition
CA210 : CH 14(LED), Test signal : Inner pattern (85IRE)
· Above 5 minutes H/run in the inner pattern. (“power on” key
of adjust remote control)
4.1.1. Connecting picture of the measuring instrument
(On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push Adjustment R/C POWER ON -> Enter
the mode of White-Balance, the pattern will come out
4.1.2. Auto-control interface and directions
1) Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10ux).
2) Adhere closely the Color Analyzer (CA210) to the module
less than 10cm distance, keep it with the surface of the
Module and Color Analyzer’s Prove vertically.(80~100°).
3) Aging time
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 15minutes.
- Using ‘no signal’ or ‘full white pattern’ or the others, check
the back light on.
4.1.3. Auto adjustment Map (RS-232C)
**Caution **
Color Temperature : COOL, Medium, Warm.
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and
adjust other two lower than C0.
(when R/G/B Gain are all C0, it is the FULL Dynamic Range of
Module)
4.2. Manual W/B process using adj. R/C
• After enter Service Mode by pushing “ADJ” key,
• Enter White Balance by pushing “
G
* After done all adjustments, Press “In-start” button and compare
Tool option and Area option
value with its BOM, if it is correctly same then unplug the AC
cable.
If it is not same, then correct it same with BOM and unplug AC
cable.
For correct it to the model’s module from factory JIG model.
* Push  The  “IN STOP KEY” after completing the function
inspection.
- 13 -
Cool 13,000k
ºK
X=0.269(±0.002)
Y=0.273(±0.002)
<Test Signal>
Medium 9,300k
ºK
X=0.285(±0.002)
Inner pattern
Y=0.293(±0.002)
(216gray,85IRE)
Warm
6,500k
ºK
X=0.313(±0.002)
Y=0.329(±0.002)
 
Full White Pattern
COLOR
ANALYZER
TYPE: CA-210
RS-232C Communication
CA-210
RS-232C COMMAND MIN
CENTER
MAX
[CMD ID DATA]
(DEFAULT)
Cool
Mid
Warm
Cool
Mid
Warm
R Gain
jg 
Ja 
jd 
00
172 
192 
192
255
G Gain 
jh 
Jb
je 
00
172 
192 
192
255
B Gain 
ji 
Jc 
jf
00
192 
192 
172 
255
R Cut 
64 
64 
64 
128
G Cut 
64 
64 
64 
128
B Cut 
64 
64 
64 
128
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Country Group
5. ADC Calibration
6. White Balance
7. Test Pattern
8. EDID D/L
9. Sub B/C
White Balance
Color Temp.
R-Gain
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern.
Reset
Cool
172
172
192
64
64
64
ON
To set
Page of 69
Display

Click on the first or last page to see other 42SL90QD-DA (CHASSIS:LT91L) service manuals if exist.