- 7 -
3) Click the Config button and Change speed
E2PROM Device setting : over the 350Khz
4) Read and write bin file
Click  “(1)Read”  tab,  and  then  load  download
file(XXXX.bin) by clicking “Read”.
5) Click “Auto(2)” tab and set as below
6) Click “Run(3)”.
7) After downloading, check “OK(4)” message. 
3-6. Download Method (By using USB 
Memory Stick) 
* Caution
- Using ‘power on’ button of the control R/C, power on TV.
- USB  file  (EPK)  version  must  be  bigger  than  downloaded
version of main B/D.
- It should be only one SW binary file in USB Stick 
(1) Using ‘Power ON’ button of the control R/C, Power on TV.
(2) Insert the USB memory stick to the SET.
(3) Display  USB  loding  message  then,  push  the  ‘Exit’  Key  of
control R/C
(4) Push  the  ‘MENU’  Key  and  move  the  cusor  ‘OPTION’  of
OSD ( Fig. 1)
* Caution : Don’t  push  the  ‘OK’  key.Just  cusor  is  on  the
‘OPTION’ menu.
(5) Push the “7” key of control R/C continuously.
Then, Display “TV Software Update” Pop-up menu. (Fig. 2)
(6) Select SW file (XXXX.bin) you want, push the “OK” Key.
(7) S/W download process is excuted automatically.
( Fig. 1)
( Fig. 2)
- 8 -
4. PCB Assembly Adjustment Method
4-1. Option Adjustment Following BOM 
Tool Option
Area Option
Option 1
Option 2
Option 3(Available for EU & Non EU model)
* Profile: Must  be  changed  the  option  value  because  being
different with some setting value depend on module,
inch and market 
* Equipment : Adjustment Remote Controller
(1) Push the IN-START key in the Adjust R/C.
(2) Enter Password number. The value of Password is “0 0 0
0”.
(3) Input  the  Option  Number  that  was  specified  in  the  BOM,
into the Shipping area.
(4) Select  “Tool  Option”  by  using 
D
/
E
(CH+/-)  key,  and  press
the number key(0~9) consecutively
ex) If  the  value  of  Tool  Option1  is  4,  input  the  data  using
number key “4” (Fig. 3)
(5) if  it  is  EU  model  (  such  as  42/50PJ**R-ZA  ),  select  “Area
option”  by  using 
D
/
E
(CH+/-)  key  ,  and  press  the  number
key(0~9) consecutively.
ex) If  the  value  of  Area  Option  is  40,  input  the  data  using
number key “40” (Fig. 3)
Caution
- Don’t  Push  “IN-STOP”  key  after  PCB  assembly
adjustment.
* PP01A/B/C Tool option
(6) EDID D/L Method
- After  software  D/L  or  PCBA  manufacturing,  you  can
download EDID Data.
- When you adjust Tool Option, H6 Model EDID download
process is executed automatically
* If the model don’t have HDMI 3, HDMI 3 will be disappeared
at OSD Window.
[Caution]
- When  you  adjust  tool  option,  don’t  connect  HDMI  or  D-
sub cable. 
- If  you  connect  some  cable,  EDID  D/L  process  will  be
failed. 
(7) Adjustment method    
Before  PCBA  check,  have  to  change  the  Tool  option  and
Area option  
[ About PDP
After  done  all  adjustments,  Press  IN-START  button  and
compare Tool option and Area option value with its BOM, if
it  is  correctly  same  then  Change  “RF  mode”  and  then
unplug the AC cable.
If it is not same, then correct it same with BOM and unplug
AC cable. 
For  correct  it  to  the  model’s  module  from  factory  JIG
model.
[ Don’t push The IN-STOP KEY after completing the function
inspection.
5. EDID(The Extended Display
Identification Data)  
Caution 
- Never    Use  the  cable(  HDMI  or  D-sub  cable)  for  EDID
Writing. 
- Automatically PP01A/B/C Model EDID download process
is executed when you adjust Tool Option.
( Fig. 3)
Model
Tool option
Area Option
42PT250R-TA
13
1
Inch
Tool
SIDE AV
0/1
HDMI
0/1/2/3
Side HDMI
0/1
COMP2
0/1
RGB
0/1
RS232C
0/1
Local Key
0 (7KEY) / 1 (8KEY)
LED TYPE
0 (RED) / 1 (RED/White) / 2 (Reserve)
USB TYPE
0 (NONE) / 1 (PHOTO, MUSIC) 
/ 2 (PHOTO, MUSIC, DivX)
- 9 -
<NON-EU AREA>
5-1. EDID Data
O
XGA EDID DATA ( 42 inch)
<Analog(RGB) : 128bytes>
<HDMI 1 : 256bytes>
<HDMI 2 : 256bytes>
<HDMI 3 : 256bytes> SIDE HDMI(HDMI 3)
6. HDCP(High-Bandwidth Digital 
Contents Protection) Download
HDCP download process is deleted in PP01A/B/C Chassis
In  PP01A/B/C  Chassis,  it  is  usi g  the  EEPROM  masking
HDCP Key
7. Manual ADC Adjustment 
(Component 1, RGB) 
Caution
- Do not connect external input cable
- Adjustment result is applied to SET On/Off later.
* Adjustment is done using internal ADC, so input signal is not
necessary.
NO
Item
Condition
Hex Data
1
Manufacturer ID
GSM
1E6D
2
Version
Digital : 1
01
3
Revision
Digital : 3
03
Inch
42PT350R-TA
Tool option
15
INCH
42
TOOL
PT350R
SIDE AV
1
HDMI
3
Side HDMI
1
COMP2
1
RGB
1
RS232C
1
Local Key
LED TYPE
USB TYPE
2
RF input
NO SIGNAL or White noise
AV / Component / RGB input
NO SIGNAL
- 10 -
7-1. COMPONENT input ADC (SD / HD), 
RGB input ADC
(1) Press  ADJ  key  on  R/C  for  adjustment.  Need  not  convert
input mode.
(2) Enter Password number. The value of Password is “0 0 0
0”.
(3) Select “0. ADC calibration” by using 
D
/
E
(CH +/-) and press
ENTER(
V
).
(4) Start  ADC  adjustment  by  using 
F
/
G
(VOL  +/-)  or  press
ENTER(
V
).
(5) Both  component  and  RGB  ADC  adjustment  are  executed
automatically 
When ADC adjustment is finished, this OSD appear.
Notice : After All mode check, set the Speaker Volume “0”.
Caution : Don’t Press the Power Key on Remote Controller.
Just AC Power Off. ( Not DC off )
Notice : From this sentence, All working is mass production.
8. POWER PCB Assy Voltage
Adjustment
(Vs voltage Adjustment)
8-1. Test Equipment:
D.M.M 1EA
8-2. Connection Diagram for Measuring
Refer to (Fig. 4)
8-3. Adjustment Method 
(1) Vs Adjustment
1) Connect  +  terminal  of  D.  M..M.  to  Vs  pin  of  P811,
connect -terminal to GND pin of P811.
2) After  turning  VR901,  voltage  of  D.M.M  adjustment  as
same as Vs voltage which on label of panel right/top
( deviation ; ±0.5V)
(2) Va Adjustment
1) Connect  +  terminal  of  D.  M..M.  to  Va  pin  of  P811,
connect -terminal to GND pin of P811.
2) After  turning  VR502,  voltage  of  D.M.M  adjustment  as
same as Va voltage which on label of panel right/top  
( deviation ; ± 0.5 V)
8-4. Adjustment of Area option.
(1) Area Option Adjustment following BOM 
(Including SKD models )
Tool Option
Area Option
Option 1
Option 2
Option 3 ( Available for EU & Non EU model )
* Profile : Must  be  changed  the  option  value  because  being
different with some setting value depend on module,
inch and market
* Equipment : Adjustment Remote Controller
1) Push the IN-START key in the Adjust R/C.
2) Enter Password number. The value of Password is “0 0
0 0”.
3) Input the Area Option Number that was specified in the
BOM, into the Shipping area.
4) Select  “Area  Option”  by  using 
D
/
E
(CH+/-)  key,  and
press the number key(0~9) consecutively
ex) If  the  value  of  Area  Option  40,  input  the  data  using
number key “40” (Fig. 3)
Caution: 
- Although  it  is  SKD  model,  adjust  area  option  in  SET
assemmbly process.
- Don’t  Push  “IN-STOP”  key  after  PCB  assembly
adjustment.
9. Adjustment of White Balance
9-1. Required Equipment
(1) Remote controller for adjustment 
(2) Color  Analyzer  (  CS-1000,  CA-100,100+,CA-210  or  same
produc : CH 10 (PDP) 
lease  adjust  CA-210,  CA-100+  by  CS-1000  before
measuring
(3) Auto W/B adjustment instrument(only for Auto adjustment)
(Fig. 4)
..
Page of 33
Display

Click on the first or last page to see other 42PT350R-TD / 42PT351R-TC / 42PT352R-TB (CHASSIS:PP11K) service manuals if exist.