Notice : From this sentence, All working is mass production.
8. POWER PCB Assy Voltage
Adjustment
(Vs voltage Adjustment)
8-1. Test Equipment:
D.M.M 1EA
8-2. Connection Diagram for Measuring
Refer to (Fig. 4)
8-3. Adjustment Method 
(1) Vs Adjustment
1) Connect + terminal of D. M..M. to Vs pin of P702,
connect -terminal to GND pin of P702.
2) After turning VR901, voltage of D.M.M adjustment as
same as Vs voltage which on label of panel right/top  (
deviation ; ±0.5V)
9. Adjustment of White Balance
9-1. Purpose and Principle for Adjustment 
of the Color Temperature
(1) Purpose: Adjust the color temperature to reduce the
deviation of the module color temperature.
(2) Principle : To adjust the white balance without the
saturation, Fix the one of R/G/B gain to C0 and decrease
the others.
(3) Adjustment mode: Two modes of Cool, Warm and Medium
9-2. Required Equipment
(1) Remote controller for adjustment 
(2) Color Analyzer : CA-100+ or CA-210 or same product
- PLASMA TV(ch : 10)
(3) Auto W/B adjustment instrument(only for Auto adjustment)
- Do the white balance adjustment under the 10LUX
[
Notice: When using the Color Analyzer with PDP,
recommend the CA-100 more than CA-210.
If CA-100 can not available, it is also good to use the CA-210.
(4) PC (for communication through RGB) 
(5) Pattern Generator (MSPG-925FA etc.)
-Before white balance, press the ADJ key and select third
row like (Fig. 5)
-To enter White-balance mode, Enter Password Number “0
0 0 0” and  select third row. 
[
Caution: System control Host should be “DDC” for adjustment.
(6) Adjust W/B DATA, for all CSM, choose ‘COPY ALL’
9-3. Connecting Diagram of Equipment for 
Measuring
(For Automatic Adjustment) 
(Method 2, using RS-232C, You connect RS-232C Cable)
(1) Enter the adjustment mode of the white balance
- Enter the white balance adjustment mode at the same time
heat-run mode when pushing the power on by power only
key
- 13 -
P811
Vs ADJ
VR901
(Fig. 4)
EZ ADJUST
0. ADC CALIBRATION  : TV
1. ADC ADJUST
2. SUB B/C ADJUST
3. W/B ADJUST
4. WHITE PATTERN   : OFF
5. EDID D/L
(Fig. 5)
3. W/B ADJUST
Mode
: TV
TEMPERATURE
: Medium
R-Gain.
: 192
G-Gain.
: 192
B-Gain.
: 192
R-Offset
: 128
G-Offset
: 128
B-Offset
: 128
COPY ALL
(Fig. 6)
Method 2-(RS-232C)
- Maintain the white balance adjustment mode with same
condition of Heat-run 
- Maintain after AC off/on in status of Heat-run pattern display
(2) Release the white balance adjustment mode
- Release the adjust mode after AC off/on or std-by off/on in
status of finishing the Hear-run mode
- Release the Adjust mode when receiving the aging off
command(F3 00 00) from adjustment equipment)
(3) Enter the adjust mode of white balance
- Enter the white balance adjustment mode with aging
command(F3, 00, FF)
9-4. Adjustment of White Balance for 
Manual Adjustment
(method 3) 
Adjustment mode: Three modes of Cool, Medium(Vivid) and
Warm
- Equipment : 1) Color analyzer(CA100+, CA210) should be
used in the calibrated ch by CS-1000(PDP :
CH10)
2) Adjustment remocon
- For manual adjustment, it is also possible by the following
sequence.
Operate the zero-calibration of the CA-100+ or CA-210, then
stick sensor to the module when adjusting.
(1) Select white pattern of heat-run by pressing “POWER ON”
key on remote control for adjustment then operate heat run
longer than 5 minutes. (recommend) 
(If not executed this step, the condition for W/B will be
different)
(2) Changing to the AV mode by remote control.(Push front-
AV)
(3) Input external pattern(85% white pattern).
(4) Stick sensor to center of the screen and select each items
(Red/Green/Blue Gain and Offset) using 
D
/
E
(CH +/-) key
on R/C..
(5) Adjust R/ G/ B Gain using 
F
/
G
(VOL +/-) key on R/C.
(6) Adjust three modes of Cool, Medium(Vivid) and Warm as
below figure.
(Fix the one of R/G/B and change the others)
- Push the “VOL + “ key : Cool, Medium, Warm
[
Refer to the below case to know what value is fixed.
[CASE]
First adjust the coordinate much away from the target value(x, y).
1. x, y > target
1) Decrease the R, G. 
2. x, y < target
1) First decrease the B gain, 
2) Decrease the one of the others.
- In case of decreasing the x, decreasing the R : fix G
- In case of decreasing the y , decreasing the G : fix R
3. x > target ,  y < target
1) First decrease B, so make y a little more than the target.
2) Adjust x value by decreasing the R
4. x < target ,  y > target
1) First decrease B, so make x a little more than the target.
2) Adjust x value by decreasing the G
(7) When adjustment is completed, Exit adjustment mode
using EXIT key on R/C.
9-5. Connecting diagram of Equipment for 
Measuring
(For Automatic Adjustment) 
(method 1, using IIC, You connect RGB Cable)
(1) Enter the adjustment mode of the white balance
- Enter the white balance adjustment mode at the same time
heat-run mode when pushing the power on by power only
key
- Maintain the white balance adjustment mode with same
condition of Heat-run 
- Maintain after AC off/on in status of Heat-run pattern display
(2) Release the white balance adjustment mode
- Release the adjust mode after AC off/on or std-by off/on in
status of finishing the Hear-run mode
- push the “power on” key(IIC Mode) on Adjust remote-
controller.
- Release the Adjust mode when receiving the aging off
command(F3 00 00) from adjustment equipment)
(3) Enter the adjust mode of white balance
- Enter the white balance adjustment mode with aging
command(F3, 00, FF)
O
Color Temperature & Color Coordinates Setting
- When adjusting the Color Temperature, Color Analyzer CA-
210(Matrix should be corrected through CH10 of CS-1000)
should be used. When CA-210 have used, it don’t need to fit
the CH10.
- Adjust the Color Temperature based below adjustment color
coordinates.
O
Target Value CA-210(LCD : CH 9, PDP : CH10), CA-100(PDP)
- 14 -
+0.003
6,500K
Warm
+0.000
9,300K
Medium
+0.000
11,000K
Cool
0.276–0.002
0.285–0.002
0.293–0.002
0.329–0.002
0.313–0.002
0.283–0.002
Y
X
uv
Temp
Color coordinate
Mode
Method 1-(I
2
C)
(Standard color coordinate and temperature when using the
CA-100+ or CA210 equipment)
O
Above optical characteristics are should be measured by
following condition.
- 15 -
+0.003
6,500K
Warm
+0.000
9,300K
Medium
+0.000
11,000K
Cool
0.276–0.002
0.285–0.002
0.293–0.002
0.329–0.002
0.313–0.002
0.283–0.002
Y
X
uv
Temp
Color coordinate
Mode
O
DDC Adjustment Command Set 
[
R/G/B GAIN max value : C0
Adjustment
Adjustment
Adjustment
- 16 -
DIAGRAMA EN BLOQUE
Page of 29
Display