4. PCB Assembly Adjustment Method
4-1. Option Adjustment Following BOM
Tool Option
Area Option
Option 1
Option 2
Option 3(Available for EU & Non EU model)
Area Option
Option 1
Option 2
Option 3(Available for EU & Non EU model)
* Profile: Must be changed the option value because being
different with some setting value depend on module, inch
and market
and market
* Equipment : Adjustment Remote Controller
(1) Push the IN-START key in the Adjust R/C.
(2) Enter Password number. The value of Password is “0 0 0
(2) Enter Password number. The value of Password is “0 0 0
0”.
(3) Input the Option Number that was specified in the BOM,
into the Shipping area.
(4) Select “Tool Option/ Area Option” by using
D
/
E
(CH+/-) key,
and press the number key(0~9) consecutively
ex) If the value of Tool Option1 is 4, input the data using
ex) If the value of Tool Option1 is 4, input the data using
number key “4” (Fig. 3)
Caution: Don’t Push “IN-STOP” key after PCB assembly
adjustment.
(5) EDID D/L Method
After software D/L or PCBA manufacturing, you can
download EDID Data.
When you adjust Tool Option, H6 Model EDID download
process is executed automatically
download EDID Data.
When you adjust Tool Option, H6 Model EDID download
process is executed automatically
* If the model don’t have HDMI 3, HDMI 3 will be disappeared
at OSD Window.
Caution: When you adjust tool option, don’t connect HDMI or D-
sub cable.
If you connect some cable, EDID D/L process will be
failed.
If you connect some cable, EDID D/L process will be
failed.
(6) Adjustment method
Before PCBA check, have to change the Tool option and Area
option
option
* About PDP
After done all adjustments, Press IN-START button and
compare Tool option and Area option value with its BOM, if it
is correctly same then Change “RF mode” and then unplug
the AC cable.
If it is not same, then correct it same with BOM and unplug AC
cable.
For correct it to the model’s module from factory JIG model.
compare Tool option and Area option value with its BOM, if it
is correctly same then Change “RF mode” and then unplug
the AC cable.
If it is not same, then correct it same with BOM and unplug AC
cable.
For correct it to the model’s module from factory JIG model.
* Don’t push The IN-STOP KEY after completing the function
inspection.
- 9 -
..
3.09
5
..
MODEL : XXXXXX Module : XXXX
S/W Ver. : X.XX ROM : XXXXXXX
UTT X Temp : xxxxx : Celsius
ADC CAL.
RGB :VV
S/W Ver. : X.XX ROM : XXXXXXX
UTT X Temp : xxxxx : Celsius
ADC CAL.
RGB :VV
OK
Component SDV
OK
Component HDV
OK
EDID RGB(OK) HDMI1(NG) HDMI2(NG) HDMI3(NG)
Tool OptionV V
4
Area OptionV V
40V
Option 1V
17
Option 2V
40
..
MODEL : XXXXXX Module : XXXX
S/W Ver. : X.XX ROM : XXXXXXX
UTT X Temp : xxxxx : Celsius
ADC CAL.
RGB :VV
S/W Ver. : X.XX ROM : XXXXXXX
UTT X Temp : xxxxx : Celsius
ADC CAL.
RGB :VV
OK
Component SDV
OK
Component HDV
OK
EDID RGB(OK) HDMI1(OK) HDMI2(OK) HDMI3(OK)
Tool OptionV V
4
Area OptionV V
40V
Option 1V
17
Option 2V
40
( Fig. 3)
5. EDID(The Extended Display
Identification Data)
Originally H6(PP91A/B) Model EDID download process is
executed when you adjust Tool Option.
executed when you adjust Tool Option.
* Caution
- Use the proper signal cable for EDID Download
- Never connect HDMI & D-SUB Cable at the same time.
- Use the proper cables below for EDID Writing
- Never connect HDMI & D-SUB Cable at the same time.
- Use the proper cables below for EDID Writing
5-1. Profile:
To be possible for plug and play
5-2. Equipment
(1) Adjusting PC with S/W for writing EDID Data.(S/W: EDID
TESTER Ver.2.5)
(2) A Jig for EDID Download
(3) Cable : Serial(9Pin or USB) to D-sub 15Pin cable, D-sub
(3) Cable : Serial(9Pin or USB) to D-sub 15Pin cable, D-sub
15Pin cable, DVI to HDMI cable.
5-3. Connection Structure
Caution: Never connect HDMI & D-SUB Cable at the same time.
5-4. EDID Data
O
XGA EDID DATA ( 42 inch)
<Analog(RGB) : 128bytes>
<HDMI 1 : 256bytes>
<HDMI 2 : 256bytes>
<HDMI 3 : 256bytes> SIDE HDMI(HDMI 3)
- 10 -
Connection Diagram of EDID
6. HDCP(High-Bandwidth Digital
Contents Protection) Download
HDCP download process is deleted in H6 models
In H6 models, it is usimg the EEPROM masking HDCP Key
In H6 models, it is usimg the EEPROM masking HDCP Key
7. Manual ADC Adjustment
(Component 1, RGB)
[Caution]
- Do not connect external input cable
- Adjustment result is applied to SET On/Off later.
- Adjustment result is applied to SET On/Off later.
* Adjustment is done using internal ADC, so input signal is not
necessary.
7-1. COMPONENT ADC (SD / HD)
(1) Convert to Component1 input source.
(2) Press ADJ key on R/C for adjustment.
(3) Enter Password number. The value of Password is “0 0 0
(2) Press ADJ key on R/C for adjustment.
(3) Enter Password number. The value of Password is “0 0 0
0”.
(4) Select “0. ADC calibration” by using
D
/
E
(CH +/-) and press
ENTER(
V
).
(5) Start ADC adjustment by using
F
/
G
(VOL +/-) or press
ENTER(
V
).
(6) ADC adjustment is executed automatically .
When ADC adjustment is finished, this OSD appear.
7-2. RGB input ADC
Auto RGB Gain/Offset Adjustment
(1) Convert to PC in Input-source
(2) Press ADJ key on R/C for adjustment.
(3) Enter Password number. The value of Password is “0 0 0
(2) Press ADJ key on R/C for adjustment.
(3) Enter Password number. The value of Password is “0 0 0
0”.
(4) Select “0. ADC calibration” by using
D
/
E
(CH +/-) and press
ENTER(
V
).
(5) Start ADC adjustment by using
F
/
G
(VOL +/-) or press
ENTER(
V
).
(6) ADC adjustment is executed automatically .
When ADC adjustment is finished, this OSD appear.
Notice : After All mode check, set the Speaker Volume “0”.
Caution : Don’t Press the Power Key on Remote Controller.
Just AC Power Off. ( Not DC off )
Just AC Power Off. ( Not DC off )
Notice : From this sentence, All working is mass production.
8. POWER PCB Assy Voltage
Adjustment
(Vs voltage Adjustment)
8-1. Test Equipment:
D.M.M 1EA
8-2. Connection Diagram for Measuring
Refer to (Fig. 4)
8-3. Adjustment Method
(1) Vs Adjustment
1) Connect + terminal of D. M..M. to Vs pin of P702,
connect -terminal to GND pin of P702.
2) After turning VR901, voltage of D.M.M adjustment as
same as Vs voltage which on label of panel right/top (
deviation ; ±0.5V)
deviation ; ±0.5V)
8-4. Adjustment of Area option.
(1) Area Option Adjustment following BOM
(Including SKD models)
Tool Option
Area Option
Option 1
Option 2
Option 3 ( Available for EU & Non EU model )
Area Option
Option 1
Option 2
Option 3 ( Available for EU & Non EU model )
* Profile : Must be changed the option value because being
different with some setting value depend on module,
inch and market
inch and market
- 11 -
RF input
NO SIGNAL or White noise
AV / Component / RGB input
NO SIGNAL
(Fig. 4)
..
* Equipment : Adjustment Remote Controller
(1) Push the IN-START key in the Adjust R/C.
(2) Enter Password number. The value of Password is “0 0 0
(1) Push the IN-START key in the Adjust R/C.
(2) Enter Password number. The value of Password is “0 0 0
0”.
(3) Input the Option Number that was specified in the BOM,
into the Shipping area.
(4) Select “Tool Option/ Area Option” by using
D
/
E
(CH+/-) key,
and press the number key(0~9) consecutively
ex) If the value of Tool Option1 is 4, input the data using
ex) If the value of Tool Option1 is 4, input the data using
number key “4” (Fig. 3)
Caution: Don’t Push “IN-STOP” key after PCB assembly
adjustment.
9. Adjustment of White Balance
9-1. Purpose and Principle for Adjustment
of the Color Temperature
(1) Purpose: Adjust the color temperature to reduce the
deviation of the module color temperature.
(2) Principle : To adjust the white balance without the
saturation, Fix the one of R/G/B gain to C0 and decrease
the others.
the others.
(3) Adjustment mode: Two modes of Cool, Warm and Medium
9-2. Required Equipment
(1) Remote controller for adjustment
(2) Color Analyzer : CA-100+ or CA-210 or same product
(2) Color Analyzer : CA-100+ or CA-210 or same product
- PLASMA TV(ch : 10)
(3) Auto W/B adjustment instrument(only for Auto adjustment)
- Do the white balance adjustment under the 10LUX
* Notice: When using the Color Analyzer with PDP,
recommend the CA-100 more than CA-210.
If CA-100 can not available, it is also good to use the CA-210.
If CA-100 can not available, it is also good to use the CA-210.
(4) PC (for communication through RGB)
(5) Pattern Generator (MSPG-925FA etc.)
(5) Pattern Generator (MSPG-925FA etc.)
-Before white balance, press the ADJ key and select third
row like (Fig. 5)
-To enter White-balance mode, Enter Password Number “0
0 0 0” and select third row.
* Caution: System control Host should be “DDC” for adjustment.
(6) Adjust W/B DATA, for all CSM, choose ‘COPY ALL’
9-3. Connecting Diagram of Equipment for
Measuring
(For Automatic Adjustment)
(Method 2, using RS-232C, You connect RS-232C Cable)
(1) Enter the adjustment mode of the white balance
- Enter the white balance adjustment mode at the same time
heat-run mode when pushing the power on by power only
key
key
- Maintain the white balance adjustment mode with same
condition of Heat-run
- Maintain after AC off/on in status of Heat-run pattern display
(2) Release the white balance adjustment mode
- Release the adjust mode after AC off/on or std-by off/on in
status of finishing the Hear-run mode
- Release the Adjust mode when receiving the aging off
command(F3 00 00) from adjustment equipment)
(3) Enter the adjust mode of white balance
- Enter the white balance adjustment mode with aging
command(F3, 00, FF)
- 12 -
EZ ADJUST
0. ADC CALIBRATION : TV
1. ADC ADJUST
2. SUB B/C ADJUST
2. SUB B/C ADJUST
3. W/B ADJUST
4. WHITE PATTERN : OFF
5. EDID D/L
5. EDID D/L
(Fig. 5)
3. W/B ADJUST
ModeVVV
: TV
TEMPERATUREVV
: Medium
R-Gain.VVV
: 192
G-Gain.VVV
: 192
B-Gain.VVV
: 192
R-OffsetVVV
: 128
G-OffsetVVV
: 128
B-OffsetVVV
: 128
COPY ALL
(Fig. 6)