- 10 -
7-5. Preparation for Adjustment
(1)  As  above  Fig.  3,  Connect  the  Set,  EDID  Download  Jig,,
PC & Cable
(2) Turn  on  the  PC  &  EDID  Download  Jig.  And    Execute  the
S/W : EDID TESTER Ver.2.5
(3) Set up the S/W option 
Repeat Number : 5
Device Address : A0
PageByte : 8
(4) Power on the Set
1) Sequence of Adjustment
1. DDC data of Analog-RGB
(1) Init the data 
(2) Load the EDID data.(Open File).
[Analog - RGB    : PP81A_RGB.ANA]
[Digital  - HDMI1 : PP81A_HDMI1.DVI]
[Digital  - HDMI2 : PP81A_HDMI2.DVI]
[Digital  - HDMI3 : PP81A_HDMI3.DVI]
(3) Set the S/W as below.
(4) Push the “Write Data & Verify” button. And confirm “Yes”.
(5) If the writing is finished, you will see the “OK”  message. 
8. HDCP
(High-Bandwidth Digital Contents Protection)
(1) Connect D-sub Signal Cable to D-Sub Jack
(2) Input HDCP key with HDCP-key- in-program
(3) HDCP  Key  value  is  stored  on  Main  M-STAR
IC(LGE6891DD)  which  is  0x80~0x90  addresses  of
0x00~0x01  page(EEPROM  MAP  PAGE0~PAGE1  /
START :A080)
(4) Play the Equipment(DVD Player) included HDCP Key and
confirm  whether  picture  is  displayed  or  not  of  using  DVD
Player.
(5) HDCP Key value is different among the sets
Open File
Open File
- 11 -
9. Adjustment of White Balance
9-1. Purpose and Principle for Adjustment 
of the Color Temperature
(1)  Purpose:  Adjust  the  color  temperature  to  reduce  the
deviation of the module color temperature.
(2)  Principle  :  To  adjust  the  white  balance  without  the
saturation,  Fix  the  one  of  R/G/B  gain  to  C0  and  decrease
the others.
(3) Adjustment mode: Two modes of Cool and Warm
(Cool data is automatically calibrated by the Medium data)
9-2. Required Equipment
(1) Remote controller for adjustment 
(2) Color Analyzer : CA-100+ or CA-210 or same product
- PLASMA TV(ch : 10)
(3) Auto W/B adjustment instrument(only for Auto adjustment)
- Do the white balance adjustment under the 10LUX
[ Notice:  When  using  the  Color  Analyzer  with  PDP,
recommend the CA-100 more than CA-210.
If CA-100 can not available, it is also good to use the CA-210.
(4) PC (for communication through RGB) 
(5) Pattern Generator (MSPG-925FA etc.)
-Before  white  balance,  press  the  ADJ  key  2times  and  do
the reset like Fig. 4
-To enter White-balance mode, press the ADJ key 2times. 
[ Caution: System control Host should be “DDC” for adjustment.
9-3. Connecting Diagram of Equipment for 
Measuring
(For Automatic Adjustment) 
(1) Enter the adjustment mode of the white balance
- Enter the white balance adjustment mode at the same time
heat-run  mode  when  pushing  the  power  on  by  power  only
key
-  Maintain  the  white  balance  adjustment  mode  with  same
condition of Heat-run 
- Maintain after AC off/on in status of Heat-run pattern display
(2) Release the white balance adjustment mode
-  Release  the  adjust  mode  after  AC  off/on  or  std-by  off/on  in
status of finishing the Hear-run mode
-  Release  the  Adjust  mode  when  receiving  the  aging  off
command(F3 00 00) from adjustment equipment)
(3) Enter the adjust mode of white balance
-  Enter  the  white  balance  adjustment  mode  with  aging
command(F3, 00, FF)
O
Color Temperature & Color Coordinates Setting
-  When  adjusting  the  Color  Temperature,  Color  Analyzer  CA-
210(Matrix  should  be  corrected  through  CH10  of  CS-1000)
should be used. When CA-210 have used, it don’t need to fit
the CH10.
-  Adjust  the  Color  Temperature  based  below  adjustment  color
coordinates.
O
Target Value CA-210(PDP : CH10), CA-100(PDP)
(Standard  color  coordinate  and  temperature  when  using  the
CA-100+ or CA210 equipment)
O
Synchronization relation between PSM and CSM
<Fig. 4>
Color Coordinate
x
0.293±0.002
0.329±0.002
9,300K
6,500K
0.000
0.003
0.285±0.002
0.313±0.002
MEDIUM
WARM
Mode
Temp
uv
CSM
Remark
Cool
Warm
Vivid
Mild
PSM
- 12 -
O
DDC Adjustment Command Set 
[ R/G/B GAIN max value : C0
9-4. Adjustment of White Balance for 
Manual Adjustment
Adjustment mode: Two modes of Medium(Vivid) and Warm
(Cool data is automatically calibrated by the Medium data)
- Equipment : 1) Color analyzer(CA100+, CA210) should be
used in the calibrated ch by CS-1000(.(LCD :
CH9, PDP : CH10)
2) Adjustment remocon
-  For  manual  adjustment,  it  is  also  possible  by  the  following
sequence.
Operate the zero-calibration of the CA-100+ or CA-210, then
stick sensor to the module when adjusting.
(1) Select white pattern of heat-run by pressing “POWER ON”
key on remote control for adjustment then operate heat run
longer than 15 minutes. (recommend) 
(If  not  executed  this  step,  the  condition  for  W/B  will  be
different)
(2)  Changing  to  the  AV  mode  by  remote  control.(Push  front-
AV)
(3) Input external pattern(85% white pattern).
(4) Stick sensor to center of the screen and select each items
(Red/Green/Blue  Gain  and  Offset)  using 
D
/
E
(CH  +/-)  key
on R/C..
(5) Adjust R/ G/B Gain using 
F
/
G
(VOL +/-) key on R/C.
(6)  Adjust  two  modes  of  Medium(Vivid)  and  Warm  as  below
figure.
(Fix the one of R/G/B and change the others)
1) Default : Medium(Vivid)
2) Push the “VOL +” key twice : Warm
[ Refer to the below case to know what value is fixed.
[CASE]
First adjust the coordinate much away from the target value(x, y).
1. x, y > target
1) Decrease the R, G. 
2. x, y < target
1) First decrease the B gain, 
2) Decrease the one of the others.
- In case of decreasing the x, decreasing the R : fix G
- In case of decreasing the y , decreasing the G : fix R
3. x > target ,  y < target
1) First decrease B, so make y a little more than the target.
2) Adjust x value by decreasing the R
4. x < target ,  y > target
1) First decrease B, so make x a little more than the target.
2) Adjust x value by decreasing the G
(7)  When  adjustment  is  completed,  Exit  adjustment  mode
using EXIT key on R/C.
Adjustment
content
Aging On/Off
input select
R GAIN
G GAIN
B GAIN
R GAIN
G GAIN
B GAIN
R GAIN
G GAIN
B GAIN
CSM modo
EEPROM Read
EEPROM Write
No
1
2
3
4
5
6
CMD
(HEX)
F3
F4
16
18
1A
16
18
1A
16
18
1A
F2
E7
E8
ADR
00
00
00
01
02
00
00
00
VALUE
FF/00
00 - FE
00 - FE
00 - FE
00 - FE
00 - FE
00 - FE
00 - FE
00 - FE
00 - FE
00
01
02
00
data
Detail
OO : OFF
01  : ON
FF  : WB Ready
0x10 : TV
0x20 : AV1
0x21 : AV2
0x23 : AV3
0x40 : Component1
0x41 : Component2
0x60 : RGB PC
0x90 : HDMI1
0x91 : HDMI2
0x92 : HDMI3
GAIN Adjsutment
CSM COOL
GAIN Adjsutment
CSM MEDIUM
GAIN Adjsutment
CSM WARM
COOL
MEDIUM
WARM
EEPROM read
EEPROM write
Color Coordinate
x
0.293±0.002
0.329±0.002
9,300K
6,500K
0.000
0.003
0.285±0.002
0.313±0.002
MEDIUM
WARM
Mode
Temp
uv
- 13 -
10. Default Value in Adjustment
10-1. White Balance
(Default values maybe modified the module condition)
10-2. Press CH write condition
(1) AC on tilme on only one after assembled automatically
(2) CH recover SVC OSD manually
12. Sound spec.
Caution: Each PCB assembly must be checked by check JIG set.
(Because  power  PCB  Assembly  damages  to  PDP
Module, especially be careful)
13. POWER PCB Assy Voltage
Adjustment
(Va, Vs voltage Adjustment)
13-1. Test Equipment:
D.M.M 1EA
13-2. Connection Diagram for Measuring
Refer to Fig. 5
13-3. Adjustment Method 
(1) Va Adjustment
1) After receiving 100% Full White Pattern, HEAT RUN.
2)  Connect  +  terminal  of  D.  M..M.  to  Va  pin  of  P812,
connect -terminal to GND pin of P812.
3)  After  turning  VR901,voltage  of  D.M.M  adjustment  as
same  as  Va  voltage  which  on  label  of  panel  right/top
(deviation; ±0.5V)
(2) Vs Adjustment
1)  Connect  +  terminal  of  D.  M..M.  to  Vs  pin  of  P812,
connect -terminal to GND pin of P812.
2)  After  turning  VR951  401,  voltage  of  D.M.M  adjustment
as same as Vs voltage which on label of panel right/top
( deviation ; ±0.5V)
<Fig. 5> Connection Diagram of Power Adjustment for Measuring
Item
Dielectric Voltage (AC <-> FG)
Dielectric Voltage (Without FG)
Value
1.5
1.5
3
3
Unit
kV
kV
Remark
At 100mA for 1sec (Line)
At 100mA for 1min (OQC)
At 100mA for 1sec (Line)
At 100mA for 1min (OQC)
Item
Min
Typ
Max
Unit
Remark
Audio Practical Max Output, L(Mono)/R
9
10
12
W
Page of 28