LG 42PG20R-TA (CHASSIS:PP81A) Service Manual ▷ View online
- 10 -
7-5. Preparation for Adjustment
(1) As above Fig. 3, Connect the Set, EDID Download Jig,,
PC & Cable
(2) Turn on the PC & EDID Download Jig. And Execute the
S/W : EDID TESTER Ver.2.5
(3) Set up the S/W option
Repeat Number : 5
Device Address : A0
PageByte : 8
Device Address : A0
PageByte : 8
(4) Power on the Set
1) Sequence of Adjustment
1. DDC data of Analog-RGB
(1) Init the data
(2) Load the EDID data.(Open File).
[Analog - RGB : PP81A_RGB.ANA]
[Digital - HDMI1 : PP81A_HDMI1.DVI]
[Digital - HDMI2 : PP81A_HDMI2.DVI]
[Digital - HDMI3 : PP81A_HDMI3.DVI]
[Digital - HDMI1 : PP81A_HDMI1.DVI]
[Digital - HDMI2 : PP81A_HDMI2.DVI]
[Digital - HDMI3 : PP81A_HDMI3.DVI]
(3) Set the S/W as below.
(4) Push the “Write Data & Verify” button. And confirm “Yes”.
(5) If the writing is finished, you will see the “OK” message.
8. HDCP
(High-Bandwidth Digital Contents Protection)
(1) Connect D-sub Signal Cable to D-Sub Jack
(2) Input HDCP key with HDCP-key- in-program
(3) HDCP Key value is stored on Main M-STAR
(2) Input HDCP key with HDCP-key- in-program
(3) HDCP Key value is stored on Main M-STAR
IC(LGE6891DD) which is 0x80~0x90 addresses of
0x00~0x01 page(EEPROM MAP PAGE0~PAGE1 /
START :A080)
0x00~0x01 page(EEPROM MAP PAGE0~PAGE1 /
START :A080)
(4) Play the Equipment(DVD Player) included HDCP Key and
confirm whether picture is displayed or not of using DVD
Player.
Player.
(5) HDCP Key value is different among the sets
Open File
Open File
- 11 -
9. Adjustment of White Balance
9-1. Purpose and Principle for Adjustment
of the Color Temperature
(1) Purpose: Adjust the color temperature to reduce the
deviation of the module color temperature.
(2) Principle : To adjust the white balance without the
saturation, Fix the one of R/G/B gain to C0 and decrease
the others.
the others.
(3) Adjustment mode: Two modes of Cool and Warm
(Cool data is automatically calibrated by the Medium data)
9-2. Required Equipment
(1) Remote controller for adjustment
(2) Color Analyzer : CA-100+ or CA-210 or same product
(2) Color Analyzer : CA-100+ or CA-210 or same product
- PLASMA TV(ch : 10)
(3) Auto W/B adjustment instrument(only for Auto adjustment)
- Do the white balance adjustment under the 10LUX
[ Notice: When using the Color Analyzer with PDP,
recommend the CA-100 more than CA-210.
If CA-100 can not available, it is also good to use the CA-210.
If CA-100 can not available, it is also good to use the CA-210.
(4) PC (for communication through RGB)
(5) Pattern Generator (MSPG-925FA etc.)
(5) Pattern Generator (MSPG-925FA etc.)
-Before white balance, press the ADJ key 2times and do
the reset like Fig. 4
-To enter White-balance mode, press the ADJ key 2times.
[ Caution: System control Host should be “DDC” for adjustment.
9-3. Connecting Diagram of Equipment for
Measuring
(For Automatic Adjustment)
(1) Enter the adjustment mode of the white balance
- Enter the white balance adjustment mode at the same time
heat-run mode when pushing the power on by power only
key
key
- Maintain the white balance adjustment mode with same
condition of Heat-run
- Maintain after AC off/on in status of Heat-run pattern display
(2) Release the white balance adjustment mode
- Release the adjust mode after AC off/on or std-by off/on in
status of finishing the Hear-run mode
- Release the Adjust mode when receiving the aging off
command(F3 00 00) from adjustment equipment)
(3) Enter the adjust mode of white balance
- Enter the white balance adjustment mode with aging
command(F3, 00, FF)
O
Color Temperature & Color Coordinates Setting
- When adjusting the Color Temperature, Color Analyzer CA-
210(Matrix should be corrected through CH10 of CS-1000)
should be used. When CA-210 have used, it don’t need to fit
the CH10.
should be used. When CA-210 have used, it don’t need to fit
the CH10.
- Adjust the Color Temperature based below adjustment color
coordinates.
O
Target Value CA-210(PDP : CH10), CA-100(PDP)
(Standard color coordinate and temperature when using the
CA-100+ or CA210 equipment)
CA-100+ or CA210 equipment)
O
Synchronization relation between PSM and CSM
<Fig. 4>
Color Coordinate
x
y
0.293±0.002
0.329±0.002
9,300K
6,500K
0.000
0.003
0.285±0.002
0.313±0.002
MEDIUM
WARM
Mode
Temp
uv
CSM
Remark
Cool
Warm
Vivid
Mild
PSM
- 12 -
O
DDC Adjustment Command Set
[ R/G/B GAIN max value : C0
9-4. Adjustment of White Balance for
Manual Adjustment
Adjustment mode: Two modes of Medium(Vivid) and Warm
(Cool data is automatically calibrated by the Medium data)
(Cool data is automatically calibrated by the Medium data)
- Equipment : 1) Color analyzer(CA100+, CA210) should be
used in the calibrated ch by CS-1000(.(LCD :
CH9, PDP : CH10)
CH9, PDP : CH10)
2) Adjustment remocon
- For manual adjustment, it is also possible by the following
sequence.
Operate the zero-calibration of the CA-100+ or CA-210, then
stick sensor to the module when adjusting.
Operate the zero-calibration of the CA-100+ or CA-210, then
stick sensor to the module when adjusting.
(1) Select white pattern of heat-run by pressing “POWER ON”
key on remote control for adjustment then operate heat run
longer than 15 minutes. (recommend)
(If not executed this step, the condition for W/B will be
different)
longer than 15 minutes. (recommend)
(If not executed this step, the condition for W/B will be
different)
(2) Changing to the AV mode by remote control.(Push front-
AV)
(3) Input external pattern(85% white pattern).
(4) Stick sensor to center of the screen and select each items
(4) Stick sensor to center of the screen and select each items
(Red/Green/Blue Gain and Offset) using
D
/
E
(CH +/-) key
on R/C..
(5) Adjust R/ G/B Gain using
F
/
G
(VOL +/-) key on R/C.
(6) Adjust two modes of Medium(Vivid) and Warm as below
figure.
(Fix the one of R/G/B and change the others)
1) Default : Medium(Vivid)
2) Push the “VOL +” key twice : Warm
(Fix the one of R/G/B and change the others)
1) Default : Medium(Vivid)
2) Push the “VOL +” key twice : Warm
[ Refer to the below case to know what value is fixed.
[CASE]
First adjust the coordinate much away from the target value(x, y).
First adjust the coordinate much away from the target value(x, y).
1. x, y > target
1) Decrease the R, G.
2. x, y < target
1) First decrease the B gain,
2) Decrease the one of the others.
2) Decrease the one of the others.
- In case of decreasing the x, decreasing the R : fix G
- In case of decreasing the y , decreasing the G : fix R
- In case of decreasing the y , decreasing the G : fix R
3. x > target , y < target
1) First decrease B, so make y a little more than the target.
2) Adjust x value by decreasing the R
2) Adjust x value by decreasing the R
4. x < target , y > target
1) First decrease B, so make x a little more than the target.
2) Adjust x value by decreasing the G
2) Adjust x value by decreasing the G
(7) When adjustment is completed, Exit adjustment mode
using EXIT key on R/C.
Adjustment
content
Aging On/Off
input select
R GAIN
G GAIN
B GAIN
R GAIN
G GAIN
B GAIN
R GAIN
G GAIN
B GAIN
CSM modo
EEPROM Read
EEPROM Write
No
1
2
3
4
5
6
CMD
(HEX)
F3
F4
16
18
1A
16
18
1A
16
18
1A
F2
E7
E8
ADR
00
00
00
01
02
00
00
00
VALUE
FF/00
00 - FE
00 - FE
00 - FE
00 - FE
00 - FE
00 - FE
00 - FE
00 - FE
00 - FE
00
01
02
00
data
Detail
OO : OFF
01 : ON
FF : WB Ready
0x10 : TV
0x20 : AV1
0x21 : AV2
0x23 : AV3
0x40 : Component1
0x41 : Component2
0x60 : RGB PC
0x90 : HDMI1
0x91 : HDMI2
0x92 : HDMI3
GAIN Adjsutment
CSM COOL
GAIN Adjsutment
CSM MEDIUM
GAIN Adjsutment
CSM WARM
COOL
MEDIUM
WARM
EEPROM read
EEPROM write
Color Coordinate
x
y
0.293±0.002
0.329±0.002
9,300K
6,500K
0.000
0.003
0.285±0.002
0.313±0.002
MEDIUM
WARM
Mode
Temp
uv
- 13 -
10. Default Value in Adjustment
10-1. White Balance
(Default values maybe modified the module condition)
10-2. Press CH write condition
(1) AC on tilme on only one after assembled automatically
(2) CH recover SVC OSD manually
(2) CH recover SVC OSD manually
12. Sound spec.
Caution: Each PCB assembly must be checked by check JIG set.
(Because power PCB Assembly damages to PDP
Module, especially be careful)
Module, especially be careful)
13. POWER PCB Assy Voltage
Adjustment
(Va, Vs voltage Adjustment)
13-1. Test Equipment:
D.M.M 1EA
13-2. Connection Diagram for Measuring
Refer to Fig. 5
13-3. Adjustment Method
(1) Va Adjustment
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D. M..M. to Va pin of P812,
2) Connect + terminal of D. M..M. to Va pin of P812,
connect -terminal to GND pin of P812.
3) After turning VR901,voltage of D.M.M adjustment as
same as Va voltage which on label of panel right/top
(deviation; ±0.5V)
(deviation; ±0.5V)
(2) Vs Adjustment
1) Connect + terminal of D. M..M. to Vs pin of P812,
connect -terminal to GND pin of P812.
2) After turning VR951 401, voltage of D.M.M adjustment
as same as Vs voltage which on label of panel right/top
( deviation ; ±0.5V)
( deviation ; ±0.5V)
<Fig. 5> Connection Diagram of Power Adjustment for Measuring
Item
Dielectric Voltage (AC <-> FG)
Dielectric Voltage (Without FG)
Value
1.5
1.5
3
3
Unit
kV
kV
Remark
At 100mA for 1sec (Line)
At 100mA for 1min (OQC)
At 100mA for 1sec (Line)
At 100mA for 1min (OQC)
Item
Min
Typ
Max
Unit
Remark
Audio Practical Max Output, L(Mono)/R
9
10
12
W
Click on the first or last page to see other 42PG20R-TA (CHASSIS:PP81A) service manuals if exist.