- 8 -
6-2. Download Steps
(1) Execute ‘ISP Tool’ program in PC, then a main window will
be opened
(2) Click the connect button and confirm “Dialog Box”.
(3) Click the Config button and Change speed
E2PROM Device setting : over the 350Khz
(4) Read and write bin file
Click “(1)Read” tab, and then load download file(XXXX.bin)
by clicking “Read”.
(5) Click “Auto(2)” tab and set as below
(6) Click “Run(3)”.
(7) After downloading, check “OK(4)” message. 
7. EDID(The Extended Display
Identification Data) / DDC
(Display Data Channel) Download
[ Caution
- Use the proper signal cable for EDID Download
- Never connect HDMI & D-SUB Cable at the same time.
- Use the proper cables below for EDID Writing
7-1. Profile:
To be possible for plug and play
7-2. Equipment
(1)  Adjusting  PC  with  S/W  for  writing  EDID  Data.(S/W:  EDID
TESTER Ver.2.5)
(2) A Jig for EDID Download
(3)  Cable  :  Serial(9Pin  or  USB)  to  D-sub  15Pin  cable,  D-sub
15Pin cable, DVI to HDMI cable.
7-3. Connection Structure
Caution: Never connect HDMI & D-SUB Cable at the same time. 
7-4. EDID Data 
O
XGA EDID DATA
<Analog : 128bytes>
<Fig. 3>  Connection Diagram of DDC Download
1
2
3
Manufaturer
Version
Revision
GSM
Digital : 1
Digital : 3
1E6D
01
03
Condition
Item
No
Hex Data
- 9 -
<HDMI 1 : 256bytes>
<HDMI 2 : 256bytes>
<HDMI 3 : 256bytes>
O
Detail EDID Options are below (
ⓐ, ⓑ, ⓒ, ⓓ, ⓔ)
ⓐ Product ID 
ⓑ Serial No
=> Controlled on production line 
ⓒ Month, Year
=> Controlled on production line:  
ex)  Monthly: ‘11’  ->  ‘0B’ 
Year:  ‘2007’ ->  ‘11’
ⓓ Model Name(Hex)
ⓔ Checksum
=> Changeable by total EDID data
* Ananlog(128Byte)
1)
2)  
*HDMI 1/2/3 (256Byte)
1)
A
B
42PG20R-TA
50PG20R-TA
Product ID
Model Name
EDID table
219D
229D
D0C3
D1C3
Hex
9D21
9D22
C3D0
C3D1
DEC
40265(A)
40266(D)
50128(A)
50129(D)
- 10 -
7-5. Preparation for Adjustment
(1)  As  above  Fig.  3,  Connect  the  Set,  EDID  Download  Jig,,
PC & Cable
(2) Turn  on  the  PC  &  EDID  Download  Jig.  And    Execute  the
S/W : EDID TESTER Ver.2.5
(3) Set up the S/W option 
Repeat Number : 5
Device Address : A0
PageByte : 8
(4) Power on the Set
1) Sequence of Adjustment
1. DDC data of Analog-RGB
(1) Init the data 
(2) Load the EDID data.(Open File).
[Analog - RGB    : PP81A_RGB.ANA]
[Digital  - HDMI1 : PP81A_HDMI1.DVI]
[Digital  - HDMI2 : PP81A_HDMI2.DVI]
[Digital  - HDMI3 : PP81A_HDMI3.DVI]
(3) Set the S/W as below.
(4) Push the “Write Data & Verify” button. And confirm “Yes”.
(5) If the writing is finished, you will see the “OK”  message. 
8. HDCP
(High-Bandwidth Digital Contents Protection)
(1) Connect D-sub Signal Cable to D-Sub Jack
(2) Input HDCP key with HDCP-key- in-program
(3) HDCP  Key  value  is  stored  on  Main  M-STAR
IC(LGE6891DD)  which  is  0x80~0x90  addresses  of
0x00~0x01  page(EEPROM  MAP  PAGE0~PAGE1  /
START :A080)
(4) Play the Equipment(DVD Player) included HDCP Key and
confirm  whether  picture  is  displayed  or  not  of  using  DVD
Player.
(5) HDCP Key value is different among the sets
Open File
Open File
- 11 -
9. Adjustment of White Balance
9-1. Purpose and Principle for Adjustment 
of the Color Temperature
(1)  Purpose:  Adjust  the  color  temperature  to  reduce  the
deviation of the module color temperature.
(2)  Principle  :  To  adjust  the  white  balance  without  the
saturation,  Fix  the  one  of  R/G/B  gain  to  C0  and  decrease
the others.
(3) Adjustment mode: Two modes of Cool and Warm
(Cool data is automatically calibrated by the Medium data)
9-2. Required Equipment
(1) Remote controller for adjustment 
(2) Color Analyzer : CA-100+ or CA-210 or same product
- PLASMA TV(ch : 10)
(3) Auto W/B adjustment instrument(only for Auto adjustment)
- Do the white balance adjustment under the 10LUX
[ Notice:  When  using  the  Color  Analyzer  with  PDP,
recommend the CA-100 more than CA-210.
If CA-100 can not available, it is also good to use the CA-210.
(4) PC (for communication through RGB) 
(5) Pattern Generator (MSPG-925FA etc.)
-Before  white  balance,  press  the  ADJ  key  2times  and  do
the reset like Fig. 4
-To enter White-balance mode, press the ADJ key 2times. 
[ Caution: System control Host should be “DDC” for adjustment.
9-3. Connecting Diagram of Equipment for 
Measuring
(For Automatic Adjustment) 
(1) Enter the adjustment mode of the white balance
- Enter the white balance adjustment mode at the same time
heat-run  mode  when  pushing  the  power  on  by  power  only
key
-  Maintain  the  white  balance  adjustment  mode  with  same
condition of Heat-run 
- Maintain after AC off/on in status of Heat-run pattern display
(2) Release the white balance adjustment mode
-  Release  the  adjust  mode  after  AC  off/on  or  std-by  off/on  in
status of finishing the Hear-run mode
-  Release  the  Adjust  mode  when  receiving  the  aging  off
command(F3 00 00) from adjustment equipment)
(3) Enter the adjust mode of white balance
-  Enter  the  white  balance  adjustment  mode  with  aging
command(F3, 00, FF)
O
Color Temperature & Color Coordinates Setting
-  When  adjusting  the  Color  Temperature,  Color  Analyzer  CA-
210(Matrix  should  be  corrected  through  CH10  of  CS-1000)
should be used. When CA-210 have used, it don’t need to fit
the CH10.
-  Adjust  the  Color  Temperature  based  below  adjustment  color
coordinates.
O
Target Value CA-210(PDP : CH10), CA-100(PDP)
(Standard  color  coordinate  and  temperature  when  using  the
CA-100+ or CA210 equipment)
O
Synchronization relation between PSM and CSM
<Fig. 4>
Color Coordinate
x
0.293±0.002
0.329±0.002
9,300K
6,500K
0.000
0.003
0.285±0.002
0.313±0.002
MEDIUM
WARM
Mode
Temp
uv
CSM
Remark
Cool
Warm
Vivid
Mild
PSM
Page of 28