LG 42PG20-UA (CHASSIS:PU84A) Service Manual ▷ View online

- 12 -
TROUBLE SHOOTING GUIDE
Power-Up Boot Fail Trouble Shooting
Check  P701 All
Voltage Level (16V, 5V)
Check Power connector
OK ?
Replace Power board
Y
N
Y
Check IC706 #2 Pin
Voltage Level 2.6V
Replace IC706 &
Recheck
Y
N
Check X100 Clock
12MHz
Replace 100
Y
N
Replace IC105 Flash Memory
Check  Q706 Output
Voltage Level (5V)
Replace  Q801
N
Y
- 13 -
TROUBLE SHOOTING GUIDE
- 14 -
TROUBLE SHOOTING GUIDE
No OSD Trouble Shooting
Check P302
#33(TXAC-) , #32(TXAC+) ,
#17(TXBC-) , #16(TXBC+)
Maybe Mstar has problems
Check LVDS Cable
Check PDP Module
Control board
Refer to Module CAS
Y
N
Y
Replace Cable
N
Y
Check PDP Vs,Va Voltage
Module 5V
Replace Power
N
Check P701 Disp_EN,
VaVs ON, 5V_MNT
Check GPIO Path
N
Y
- 15 -
TROUBLE SHOOTING GUIDE
No OSD Trouble Shooting (Module Power Sequence)
Normal Display
Vcc
(5V)
Va
Vs
DISPEN
T
VaR
T
VsR
T
On
T
VaF
T
VsF
T
Off
1)
Power_on
3 Sec
Power_off
3 Sec
Min
100ms
 Min.
2Frame (Recommend: 2 sec)
msec
500
90
Falling Time of Vs (90% to 10%)
T
VsF
msec
2000
600
Time interval between 90% of  Vcc and 90% of Vs
when Power On
T
on
 +
T
VsR
msec
800
100
Rising Time of Vs (10% to 90%)
T
VsR
msec
300
50
Falling Time of Va (90% to 10%)
T
VaF
msec
300
10
Rising Time of Va (10% to 90%)
T
VaR
msec
-
20
Time interval between 10% of Vs and 90% of Vcc
 when Power Off
T
Off
msec
-
500
Time interval between 90% of Vcc and 10% of Vs
when Power On
T
On
unit
Max.
Min.
Description
Symbol
Page of 49