DOWNLOAD LG 42PC5RH-TB (CHASSIS:PP78A) Service Manual ↓ Size: 14.72 MB | Pages: 40 in PDF or view online for FREE

Model
42PC5RH-TB (CHASSIS:PP78A)
Pages
40
Size
14.72 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / Plasma
File
42pc5rh-tb-chassis-pp78a.pdf
Date

LG 42PC5RH-TB (CHASSIS:PP78A) Service Manual ▷ View online

- 9 -
(8) Click OK button at the "edit window".
(9) Under Downloading process.
(10) If download is failed, for example "No acknowledge from
slave". Execute download again from(1).
6-2.Download method 2 (AV Plate Ass’y)
(1) Push S/W ‘ON" (connect SCL to GND using switch at Jig )
and connect the download jig to D-sub jack.
(2) Supply the power (Stand-by 5V) and wait for 3 seconds.
(3) Push the S/W off.(Disconnect SCL to GND using switch at jig).
(4)  Execute  ‘Download.vi2c’  program  in  PC,  then  a  main
widow will be opened.
(5) Double click the blue box and confirm "Bootloader Version" as 42.
(6) Click the "Erase Flash" button.
(7) Double click the download file low then, "edit" window will
be opened.
(8)  Chick  the  choice  button  I  n  the  "edit  window",  then  "file
choice window’ will be opened.
(9) Click the “load > flash” button.
(10)  Choose  the  Hex  file  in  folder  and  execute  downloading
with click "open button".
Push S/W
Push S/W
A
You must verify the words of “0xfffff” in the black box(A)  of figure.
(In case of H3 Service it is 0x7ffff : If you make H4 service after
the H3 service, there could be some problem)
- 10 -
(11) Click OK button at the "edit window".
(12) Under Downloading progress.
(13) If download is failed, for example "No acknowledge from
slave", execute download again from (1).
6-3.Download method 3 (SET)
(1)  Push  the  “Tilt”  button  in  an  Adjust  Remocon  Then  the
PLASMA TV will change a “slave mode”.
(2) Connect Zig to TV using a D-sub cable.
(3)  Execute  ‘Download_CS.vi2c’  program  in  PC,  then  a  main
widow will be opened.
(4) Click "GO" button.
If  you  don’t  push  the  “go”,  the  Hex  file  would  not  be
downloaded  although  the  download  proceeds  normally  at
first glance.
(5)  Double  click  the  blue  box  and  confirm  "Bootloader
Version" as 42.
(6) Click the "Erase Flash" button.
(7) Double click the download file low then, "edit" window will
be opened.
(8)  Chick  the  choice  button  I  n  the  "edit  window",  then  "file
choice window’ will be opened.
(9) Click the “load > flash” button.
A
You must verify the words of “0xfffff” in the black box(A) of figure.
(In case of H3 Service it is 0x7ffff : If you make H4 service after
the H3 service, there could be some problem)
- 11 -
(10)  Choose  the  Hex  file  in  folder  and  execute  downloading
with click "open button".
(11) Click OK button at the "edit window".
(12) Under Downloading progress.
(13) If download is failed, for example "No acknowledge from
slave", execute download again from (1).
7. Channel memory download
7-1. Profile 
:  This  is  for  downloading  the  s/w  to  the  flash  memory  of  the
vctp(IC500)
7-2. Required Test Equipment
(1) PC.
(2) Visual IIC program.
(3) Download jig.
7-3. Connection structure
(1) Connect the download jig to D-sub jack.
(2)  Execute  ‘Channel.vi2c’  program  in  PC,  then  a  main
window will be opened.
7-4. Connection condition
(1) IC name and circuit number : VCTP and IC500.
(2) Use voltage : 3.3V.
(3) SCL : 15pin.
(4) SDA : 12pin.
(5) Tact time : about 3seconds.
7-5. Download method
(1) Connect the download jig to D-sub jack.
(2)  ‘Execute  ‘Channel  vi2c’  program  in  PC,  then  a  main
window will be opened.
(3)  Push  the  button  change  and  select  the  Channel  memory
data.
(4) Check the communication is OK or not.
=>  Push  the  Read  area  (Ackn.  Check)  and  check  Cyan  area
is OK message.
(5) Push the Update NVM from File
- 12 -
8. Tool Option Area Option Change
8-1. Profile 
: Must be changed the option value because being different with
some setting value depend on module, inch and market.
8-2. Required Test Equipment
1) Adjustment remocon.
8-3. Adjustment method
Before PCB check, have to change the Tool option and Area option.
Option values are below.
(If on changed the option, the input menu can differ the model spec.)
The input methods are same as other chassises.(Use adj Key
on the Adjust Remocon)
*  After  done  all  adjustments,  Press  ADJ  button  and  compare
Tool  option  and  Area  option  value  with  its  BOM,  if  it  is
correctly same then unplug the AC cable. 
If it is not same, then correct it same with BOM and unplug AC cable.
For correct it to the model’s module from factory JIG model.
9. Color carrier Adjustment
(Inspection process)
9-1. Profile 
:  To  have  the  margin  about  the  deviation  of  color  carrier  to
satisfy the spec.
9-2. Required Test Equipment
1) Adjustment remocon.
2) Pal RF signal.
9-3. Connection
: TV set should connected with the pal RF signal(EU 5CH).
9-4. Adjustment method
(1) tuning the RF signal
ZA/ZB, TA/TB : PAL Philips Pattern (with Color Bar)
(2) push the “adj” key in the adjustment remocon.
10. POWER PCB Assy Voltage
Adjustments 
(Va, Vs Voltage adjustments)
10-1. Profile 
: To supply the Va, Vs voltage that the module want.
10-2. Required Test Equipment
(1) Stick for adjustment.
(2) DMM.
10-3. Connection structure
10-4. Connection Diagram for Measuring
: refer to (Fig. 1)
10-5. Adjustment Method
(1) Va Adjustment
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D. M..M. to Va pin of P812, connect
-terminal to GND pin of P812.
3)  After  turning  VR901,voltage  of  D.M.M  adjustment  as
same  as  Va  voltage  which  on  label  of  panel  right/top.
(deviation; 
±0.5V)
(2) Vs Adjustment
1) Connect + terminal of D. M..M. to Vs pin of P812, connect
-terminal to GND pin of P812.
2)  After  turning  VR951,  voltage  of  D.M.M  adjustment  as
same  as  Vs  voltage  which  on  label  of  panel  right/top.
(deviation ; 
±0.5V)
(Fig. 1) Connection Diagram of power adjustment for measuring.
Each PCB assembly must be checked by check JIG set.
(Because  power  PCB  Assembly  damages  to  PDP  Module,
especially be careful)
42
XGA
PC5R(PC51)
PC6R
PC7R
PB3R
TOOL OPTION
ZA/ZB
TA/TB
2252
2508
2764
3020
4300
4556
4814
5068
Page of 40
Display