LG 42PC5R-TB (CHASSIS:PP78A) Service Manual ▷ View online

- 13 -
11-6. EDID Data
(1) XGA
<Analog (RGB) >
< Digital1 (HDMI/DVI1) >
< Digital2 (HDMI/DVI2) >
=> Detail EDID Options are below(1,2,3,4,5)
1. Product ID
2. Serial No :  Controlled on production line
3. Month, Year : Controlled on production line
ex) Monthly: '03'   =>  '03' 
Year:  '2005' =>  '0F'
4. Model Name :  model name -> LG TV
- LG TV
5. Checksum (7EH) -> Changeable by total EDID data.
12. Adjustment of White Balance
12-1. Purpose and Principle for adjustment
of the color temperature
(1) Purpose : Adjust the color temperature to reduce the
deviation of the module color temperature.
(2) Principle : To adjust the white balance without the
saturation, Fix the one of R/G/B gain to 80 and decrease
the others.
12-2.Adjustment mode
: Two modes of Cool and Warm.(Medium data is
automatically calibrated by the cool data)
12-3. Required Equipment
(1) Remote control for adjustment.
(2) Color Analyzer.(CA-110 or same product) - CH : 10
(3) Auto W/B adjustment instrument.(only for Auto adjustment)
12-4. Connecting diagram of equipment for
measuring 
(For Automatic Adjustment)
(1) Enter the DDC adjust mode.
- Enter the white balance adjustment mode at the same
time heat-run mode when pushing the power on by power
only key.
- Maintain the white balance adjustment mode with same
condition of Heat-run.
-> Maintain after AC off/on in status of Heat-run pattern display.
(2) Release the DDC adjust mode.
- Release the adjust mode after AC off/on or std-by off/on
in status of finishing the Hear-run mode.
- Release the Adjust mode when receiving the aging off
command(F3 00 00) from adjustment equipment.
- Need to transmit the aging off command to TV set after
finishing the adjustment.
* Standard color coordinate and temperature when using the
CA-110 or CA210 equipment.
* Synchronization relation between PSM and CSM.
Model
Name
42PC5R
(42PC51)
DEC
40079 (A)
40080 (D)
Product ID
HEX
9C8F
9C90
EDID table
8F9C
909C
Color Coordinate
x
0.283±0.002
0.293±0.002
0.329±0.002
11,000K
9,300K
6,500K
0.000
0.000
0.003
0.276±0.002
0.285±0.002
0.313±0.002
COOL
MEDIUM
WARM
Mode
Temp
uv
CSM
Remark
Cool
Normal
Warm
Dynamic
Standard
Mild
PSM
1
2
3
4
4
5
1
2
3
4
4
5
5
1
2
3
4
4
5
5
- 14 -
(3) DDC adjustment support command set.
* R/G/B GAIN max value : 80
12-5. Adjustment of White Balance
(For Manual adjustment)
- Adjustment mode : Two modes of Cool (Dynamic) and
Warm(Mild).
(Medium data is automatically calibrated by the cool data)
- Color analyzer(CA110, CA210) should be used in the
calibrated ch by CS-1000.(PDP : CH10)
- Operate the zero-calibration of the CA-110 or CA-210, then
stick sensor to the module when adjusting.
- For manual adjustment, it is also possible by the following
sequence.
(1) Select RF no signal by pressing “POWER ON” key on
remote control for adjustment then operate heat run more
than 15 minutes. 
(If not executed this step, the condition for W/B will be differ.)
(2) Changing to the av mode by pushing the input or front av
key.(av mode : av1 or av2 or av3)
(3) Display the internal pattern of the VCT-Pro IC by pushing
the IN-START.
(4) Stick sensor to center of the screen and select each items
(Red/Green/Blue Gain and Offset) using 
D
/
(CH+/-) key
on R/C.
(5) Adjust R Gain / B Gain using 
F
/
G
(VOL+/-) key on R/C.
(6) Adjust two modes of Cool(Dynamic) and Warm(Mild) as
below figure.
(Fix the one of R/G/B and change the others)
1. Push the one time the in-start key : Dynamic(Cool)
2. Push the two more the in-start key : Mild(Warm)
* Refer to the below case to know what value is fixed.
* CASE
- First adjust the coordinate much away from the target
value(x, y).
1) x, y > target
(1) Decrease the R, G. 
2) x, y <  target
(1) First decrease the B gain.
(2) Decrease the one of the others.
- In case of decreasing the x, decreasing the R : fix G
- In case of decreasing the y , decreasing the G : fix R
3) x  > target ,  y < target
(1) First decrease B, so make y a little more than the
target.
(2) Adjust x value by decreasing the R.
4) x < target ,  y > target
(1) First decrease B, so make x a little more than the
target.
(2) Adjust x value by decreasing the G.
(7) When adjustment is completed, Exit adjustment mode
using EXIT key on R/C.
13. Input the Shipping Option Data
(1) Push the ADJ key in a Adjust Remote control.
(2) Input the Option Number that was specified in the BOM,
into the Shipping area.
(3) The work is finished, Push 
A
Key.
14. Default Value in Adjustment mode
(Default values maybe modified the module condition)
14-1. White Balance
16. Sound spec.
Adjustment
Aging On/Off
Input select
R GAIN
G GAIN
B GAIN
R GAIN
G GAIN
B GAIN
R GAIN
G GAIN
B GAIN
CMD(HEX)
F3
F4
16
18
1A
16
18
1A
16
18
1A
ADR
00
00
00
01
02
VALUE
FF/00
00 - FE
00 - FE
00 - FE
00 - FE
00 - FE
00 - FE
00 - FE
00 - FE
00 - FE
Detail
OO : OFF
01  : ON
FF  : WB Ready
0x10 : TV
0x20 : AV1
0x21 : AV2
0x23 : AV3
0x40 : Component1
0x50 : RGB DTV
0x60 : RGB PC
0x90 : HDMI1 DTV
GAIN adjustment
CSM COOL
GAIN adjustment
CSM NORMAL
GAIN adjustment
CSM WARM
Color Coordinate
x
0.283±0.002
0.293±0.002
0.329±0.002
11,000K
9,300K
6,500K
0.000
0.000
0.003
0.276±0.002
0.285±0.002
0.313±0.002
COOL
MEDIUM
WARM
Mode
Temp
uv
Item
Dielectric Voltage (AC <-> FG)
Dielectric Voltage (Without FG)
Value
1.5
1.5
3
3
Unit
kV
kV
Remark
At 100mA for 1sec (Line)
At 100mA for 1min (OQC)
At 100mA for 1sec (Line)
At 100mA for 1min (OQC)
Item
Min
Typ
Max
Unit
Remark
Audio Practical Max Output, L(Mono)/R
9
10
12
W
PDP
<Default Value on OSD>
- 15 -
TROUBLESHOOTING
1. No power
(1) Symptom
1) Minute discharge does not occur at module.
2) Front LED does not activate.
(2) Press check
Plug in the power cord
Start Check
No
Yes
Is the power cord
plugged in? 
Connect the cable.
Plasma(CN1)
No
Yes
Are the line filter and
PSU connected?
Replace the fuse.
No
Yes
Is the correct fuse for
the PSU in place?
Plasma(F101)
Connect the 13-14pin cable.
Next remove all cables connected to the PSU and
switch the AV voltage to manual.
If the ST-by 5V does not operate, replace the PSU.
No
Yes
Is the PSU and 13-
14pin cable connected
to the VSC board?
- 16 -
2. Protect mode
(1) Symptom
1) After lighting once it does not discharge minutely from the module. 
2) The relay falls.(there is an audible “Click”.)
3) The color of the front LED turns from green to red.
(2) Follow check
Is the Power Board
normal ?
Replace Power Board.
Is the output the normal Low/High
voltage except for the Stand-by 5V?
Yes
No
No
Are all the connectors
normal?
Replace the connector.
Replace the fuse.
Replace the Y-Board.
After checking each connector does
is operate correctly?
Yes
No
No
Is the Y-Board
normal?
Is the appropriate
fuse (FS2,FS3) on the
Y-B/D?
Is the output voltage
normal after removing the
P1 connector of the Y-B/D?
Yes
No
No
Replace the Z-Board.
Is the Z-Board
normal?
Is appropriate
fuse (FS1,FS2) on 
the Z-B/D?
Is the output voltage
normal after removing the
P1 connector of the Z-B/D?
Yes
No
No
Is the X- Board
normal?
Is the 
output voltage normal 
after removing the  P100, 110,
200, 210 connector of
the X-B/D?
After removing the P100, 110 and the output
voltage is normal : Replace the Right X-B/D
After removing the P200, 210 and the output
voltage is normal : Replace the Left X-B/D
No
Yes
Replace the fuse.
Yes
Start Check
Page of 38