DOWNLOAD LG 42PC1D-UB / 42PC1DA-UB (CHASSIS:PA-61B) Service Manual ↓ Size: 27.82 MB | Pages: 46 in PDF or view online for FREE

Model
42PC1D-UB 42PC1DA-UB (CHASSIS:PA-61B)
Pages
46
Size
27.82 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / Plasma
File
42pc1d-ub-42pc1da-ub-chassis-pa-61b.pdf
Date

LG 42PC1D-UB / 42PC1DA-UB (CHASSIS:PA-61B) Service Manual ▷ View online

- 6 -
REMOTE CONTROL KEY FUNCTIONS
When using the remote control, aim it at the remote control sensor on the TV.
APM   
CC
AUTO DEMO M/C EJECT
1
2
3     
4
5
6    
7
8
0
9   
FLASHBK
VOL
CH
MUTE
FAV
PAGE
PAGE
MENU
INFO   i
TV GUIDE
ENTER
EXIT
SAP
CC
RAT
IO
POWER
DAY -
DAY+
VCR
TV
DVD
AUDIO
CABLE
STB
MODE
TV INPUT
INPUT
MODE
DAY+/DAY-
MENU
INFO
TV GUIDE 
THUMBSTICK
(Up/Down/Left
Right/ENTER)
EXIT
SAP
CC
RATIO
VOLUME UP
/DOWN
MUTE
FAV
CHANNEL
UP/DOWN
PAGE UP/
PAGE DOWN
— (DASH)
FLASHBK
Select the remote operating mode: TV, DVD, VCR,
AUDIO, CABLE or STB. 
Control video cassette recorders or DVD players.
Move the Listings Grid forward or backward in 24
hour increments.
Displays the main menu. Enters or exits a Panel
Menu in the TV Guide On Screen system.
Display information at the top of the screen. 
Displays the TV Guide On Screen system.
Navigate the on-screen menus and adjust the sys-
tem settings to your preference.
Clear all on-screen displays and return to TV view-
ing from any menu.
Analog mode: Selects MTS sound(Mono, Stereo, and a SAP)
DTV mode: Change the audio language.
Select a closed caption.
(*In DTV/CADTV mode
Change the aspect ratio.
Increase/decrease the sound level.
Switch the sound on or off.
Scroll through the programmed Favorite channels.
Select available channels.
Move from one full set of screen information to the
next one.
Used to enter a program number for multiple pro-
gram channels such as 2-1, 2-2, etc.
Tune to the last channel viewed.
VCR/DVD 
control buttons
NUMBER but-
DESCRIPTION OF CONTROLS
- 7 -
APM
TIMER
ADJUST
SWAP
PIP CH +
PIP CH -
PIP
PIP INPUT
7
8
0
9   
FLASHBK
EZ SOUND
EZ PIC
Inside the Sliding Cover
POWER
TV INPUT
INPUT
Turns your TV or any other
programmed equipment on or
off, depending on the mode.
In AV 1-2, Component 1-2,
RGB-DTV (or RGB-PC),
HDMI1/DVI, and HDMI2 input
sources, screen returns to the
last TV channel.
External input modes rotate in
regular sequence: Antenna,
Cable, AV1-2, Component 1-
2, RGB-DTV (or RGB-PC),
HDMI1/DVI and HDMI2 (AV 1-
2, Component 1-2, RGB-DTV
(or RGB-PC), HDMI1/DVI,
and HDMI2 input sources are
linked automatically, only if
these are connected ).
TIMER
APM
ADJUST
Select the amount of time before your TV turns off auto-
matically. 
Compare the Daylight, Normal, Night Time and
User1(or2) on the screen. 
Adjust the screen position,size,and phase in PC mode. 
PIP
PIPCH-
/PIPCH+  
PIP INPUT
SWAP
EZ PIC
EZ SOUND
Switches the sub picture PIP, POP, Twin
picture or off mode. 
Changes the PIP channel. 
Select the connected input source for the
sub-picture. 
Exchange the main/sub images. 
Adjust the factory preset picture depend
on the viewing environment. 
Select the appropriate type of sound for
type of program. 
DESCRIPTION OF CONTROLS
- 8 -
The specifications shown above may be changed without prior notice for quality improvement.
42PC1DA
(42PC1DA-UB)
MODELS
44.4 x 29.5 x 15.0 inches
1129.0 x 748.5 x 380.0 mm
44.4 x 27.4 x 4.1 inches
1129.0 x 695.0 x 103.7 mm
61.1 pounds / 27.7 kg
53.4 pounds / 24.2 kg
AC100-240V ~ 50/60Hz
NTSC-M, ATSC, 64 & 256 QAM
VHF 2-13, UHF 14-69, CATV 1-135, DTV 2-69, CADTV 1-135
75 ohm
32 ~ 104°F (0 ~ 40°C)
Less than 80%
-4 ~ 140°F (-20 ~ 60°C)
0 ~ 85%
Dimensions
(Width x Height x Depth)
Weight
Power requirement
Television System
Program Coverage
External Antenna
Impedance
Environment condition
including stand
excluding stand
including stand
excluding stand
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
SPECIFICATIONS
1. Application Object
These instructions are applied to all of the PDP TV, PA61B.
2. Notes
(1) Because this is not a hot chassis, it is not necessary to use
an isolation transformer. However, the use of isolation
transformer will help protect test equipment.
(2) Adjustments must be done in the correct order.
(3) The adjustments must be performed in the circumstance of
25±5°C of temperature and 65±10% of relative humidity if
there is no specific designation.
(4) The input voltage of the receiver be must kept 110V, 60Hz
when adjusting.
(5) The receiver must be operational for about 15 minutes
prior to the adjustments.  
O
Preliminary action is applied to the test for afterimage
discharge detection, and 100% FULL WHITE PATTERN
must be operated automatically.
O
Test for afterimage discharge detection
1) After pressing Power Only key(only operating by
pressing Power Only key), Full Test Pattern(2 min
30sec) --> Full Black Pattern(30sec) --> After this state,
Full White Pattern is displayed.
(but you must preset the program for Full White State
when you press the Main Power Off/On) 
2) Pattern Mode is deselected by pressing CH +/-, Exit Key.
[
Set is activated HEAT-RUN without signal generator in this
mode.
3. EPLD Download
(1) Test Equipment: PC, Jig for download
(2) Connect the power of VSC B/D.
(3) Execute download program(iMPACK) of PC.
(4) After executing the hot key on the Programmer, click icon
(5) End after confirming
4. Gemstar VBI Micom Download 
4-1. Preparation for Adjustment
(1) As shown below, connect the MPLAB ICD2 equipment, PC
and Digital Connector.
(2) Turn on the MPLAB ICD2 POWER Supply.
(3) After turn on the PC and MONITOR, select the ‘MPLAB
IDE’ from the screen.
4-2. Adjustment Sequence
(1) When the program is executed, select the MPLAB ICD2
from Programmer -> Select Programmer . 
- 9 -
ADJUSTMENT INSTRUCTIONS
+13V
<Digital Board>
Connect the MPLAB ICD2 and connector of Digital Board
Connect the RS-232 or USB Cable
GND
Data
PC
VSC
B/D
Connection Diagram of EPLD Download
Test Pattern 2min 30sec
Test Pattern 30sec
If you turn on a still screen more than 20 minutes (Especially
Digital pattern(13 CH), Cross Hatch Pattern), an afterimage
may occur in the black level part of the screen.
Page of 46
Display

Click on the first or last page to see other 42PC1D-UB / 42PC1DA-UB (CHASSIS:PA-61B) service manuals if exist.