1, 2.  Check IR cable condition between IR & Main board.
3.      Check the st-by 3.3V on the terminal 6.
4. When checking the Pre-Amp when the power is in ON condition, it is normal when the 
Analog Tester needle moves slowly, and defective when it does not move at all. 
Standard Repair Process Detail Technical Manual
Remote controller operation checking method
D. Function error_ No response in remote controller,
key error
<ALL MODELS>
A27
Established 
date 
Revised 
date 
Error 
symptom
Content
LCD  TV
A27
1
2
P2401, P2402
1
EYEQ_SCL
2
EYEQ_SDA
3
GND
4
KEY1
5
KEY2
6
St 3.3V
7
GND
8
LED_B
9
IR
10
GND
11
Normal 3.3V
12
LED_R
13
GND
14
Soft Touch_SCL
15
Soft Touch_SDA
3
4
2011. 2 .07
Checking order
1, 2.  Check IR cable condition between IR & Main board.
3.      Check the st-by 3.3V on the terminal 6.
4. When checking the Pre-Amp when the power is in ON condition, it is normal when the 
Analog Tester needle moves slowly, and defective when it does not move at all. 
Standard Repair Process Detail Technical Manual
Remote controller operation checking method
D. Function error_ No response in remote controller,
key error
<ALL MODELS>
A27
Established 
date 
Revised 
date 
Error 
symptom
Content
LCD  TV
A27
1
2
P2401, P2402
1
EYEQ_SCL
2
EYEQ_SDA
3
GND
4
KEY1
5
KEY2
6
St 3.3V
7
GND
8
LED_B
9
IR
10
GND
11
Normal 3.3V
12
LED_R
13
GND
14
Soft Touch_SCL
15
Soft Touch_SDA
3
4
2011. 2 .07
Checking order
1, 2.  Check IR cable condition between IR & Main board.
3.      Check the st-by 3.3V on the terminal 6.
4. When checking the Pre-Amp when the power is in ON condition, it is normal when the 
Analog Tester needle moves slowly, and defective when it does not move at all. 
Standard Repair Process Detail Technical Manual
Remote controller operation checking method
D. Function error_ No response in remote controller,
key error
<ALL MODELS>
A27
Established 
date 
Revised 
date 
Error 
symptom
Content
LCD  TV
A27
1
2
P2401, P2402
1
EYEQ_SCL
2
EYEQ_SDA
3
GND
4
KEY1
5
KEY2
6
St 3.3V
7
GND
8
LED_B
9
IR
10
GND
11
Normal 3.3V
12
LED_R
13
GND
14
Soft Touch_SCL
15
Soft Touch_SDA
3
4
2011. 2 .07
Checking order
1, 2.  Check IR cable condition between IR & Main board.
3.      Check the st-by 3.3V on the terminal 6.
4. When checking the Pre-Amp when the power is in ON condition, it is normal when the 
Analog Tester needle moves slowly, and defective when it does not move at all. 
Standard Repair Process Detail Technical Manual
Remote controller operation checking method
D. Function error_ No response in remote controller,
key error
<ALL MODELS>
A27
Established 
date 
Revised 
date 
Error 
symptom
Content
LCD  TV
A27
1
2
P2401, P2402
1
EYEQ_SCL
2
EYEQ_SDA
3
GND
4
KEY1
5
KEY2
6
St 3.3V
7
GND
8
LED_B
9
IR
10
GND
11
Normal 3.3V
12
LED_R
13
GND
14
Soft Touch_SCL
15
Soft Touch_SDA
3
4
2011. 2 .07
Page of 89