LG 42LS341C / 42LS3450 / 42LS345S / 42LS345T (CHASSIS:LD21C) Service Manual ▷ View online
- 13 -
* Manual W/B process using adjust Remote control.
▪ After enter Service Mode by pushing "ADJ" key,
▪ Enter White Balance by pushing "►" key at "8. White
Balance".
* After you finished all adjustments, Press "In-start" key and
compare Tool option and Area option value with its BOM, if
it is correctly same then unplug the AC cable. If it is not
same, then correct it same with BOM and unplug AC cable.
For correct it to the model's module from factory Jig model.
* Push the "IN STOP" key after completing the function
inspection. And Mechanical Power Switch must be set
“ON”.
4.2. EYE-Q function check
(1) Turn on TV.
(2) Press EYE key of Adjustment remote control.
(3) Cover the Eye Q II sensor on the front of the using your
hand and wait for 6 seconds.
(4) Confirm that R/G/B value is lower than 10 of the "Raw
Data (Sensor data, Back light)". If after 6 seconds, R/G/B
value is not lower than 10, replace Eye Q II sensor.
(5) Remove your hand from the Eye Q II sensor and wait for 6
seconds.
(6) Confirm that "ok" pop up. If change is not seen, replace
Eye Q II sensor.
4.3. Outgoing condition Configuration
■ When pressing IN-STOP key by SVC remocon, Red LED
are blinked alternatively. And then automatically turn off.
(Must not AC power OFF during blinking)
5. HI-POT Test
5.1. HI-POT auto-check preparation
- Check the POWER cable and SIGNAL cable insertion condition
5.2. HI-POT auto-check
(1) Pallet moves in the station. (POWER CORD / AV CORD is
tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) HI-POT test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, GOOD Lamp on and move to next proc-
ess automatically.
5.3. Checkpoint
(1) Test voltage
- Touchable Metal : 3KV / min at 100mA
- SIGNAL : 3KV / min at 100mA
(2) TEST time: 1 second. (case : mass production )
(3) TEST POINT
- Touchable Metal => LIVE & NEUTRAL : Touchable Metal.
- SIGNAL => LIVE & NEUTRAL : SIGNAL.
6. Model name & Serial number D/L
▪ Press “Power on” key of service remote control.
(Baud rate : 115200 bps)
▪ Connect USB to RS232 Signal Cable to USB Jack.
▪ Write Serial number.
▪ Must check the serial number at the Diagnostics of SET UP
menu.(Refer to below)
6.1. Signal Table
CMD : A0h
LENGTH : 85~94h (1~16 bytes)
ADH : EEPROM Sub Address high (00~1F)
ADL : EEPROM Sub Address low (00~FF)
Data : Write data
CS : CMD + LENGTH + ADH + ADL + Data_1 +...+ Data_n
Delay : 20ms
6.2. Comand Set
* Description
FOS Default write : <7mode data> write
Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0,
Phase
Data write : Model Name and Serial Number write in EEPROM,.
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Country Group
6. Area Option
7. ADC Calibration
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Country Group
6. Area Option
7. ADC Calibration
8. White Balance
►
9. 10 Point WB
10. Test Pattern
11. EDID D/L
12. Sub B/C
13. Touch Sensitivity Setting
10. Test Pattern
11. EDID D/L
12. Sub B/C
13. Touch Sensitivity Setting
White Balance
Color Temp.
R-Gain
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern
Backlight
Reset
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern
Backlight
Reset
Cool
172
172
192
172
192
64
64
64
64
64
ON
100
To Set
CMD
LENGTH
ADH
ADL
DATA_1
. . .
Data_n
CS
DELAY
Adjust mode
CMD(hex)
LENGTH(hex)
Description
EEPROM WRITE
A0h
84h+n
n-bytes Write (n = 1~16)
- 14 -
6.3. Method & notice
(1) Serial number D/L is using of scan equipment.
(2) Setting of scan equipment operated by Manufacturing
Technology Group.
(3) Serial number D/L must be conformed when it is produced in
production line, because serial number D/L is mandatory by
D-book 4.0.
* Manual Download(Model Name and Serial Number)
If the TV set is downloaded by OTA or Service man, sometimes
model name or serial number is initialized.(Not always)
There is impossible to download by bar code scan, so It need
Manual download.
1) Press the "Instart" key of Adjustment remote control.
2) Go to the menu "6.Model Number D/L" like below photo.
3) Input the Factory model name or Serial number like photo.
4) Check the model name Instart menu. → Factory name displayed.
(ex 32LV3400-ZG)
5) Check the Diagnostics.(DTV country only) → Buyer model
displayed.(ex 32LV3400-ZG)
7. MAC Address & CI+ key download
7.1 MAC Address
7.1.1 Equipment & Condition
▪ Play file : Serial.exe
▪ MAC Address edit
▪ Input Start / End MAC address
7.1.2 Download method
(1) Communication Prot connection
Connection : PCBA (USB Port)
→
USB to Serial Adapter
(UC-232A)
→
RS-232C cable
→
PC(RS-232C port)
* Caution : LJ21* chassis support only UC-232A driver. (only
use this one.)
(2) MAC Address & CI+ Key Download
▪ Set CI+ Key path Directory at Start Mac & CI+ Download
Programme
▪ Com 1,2,3,4 and 115200(Baudrate)
▪ Port connection button click(1)
▪ Push the (2) MAC Address write.
▪ At success Download, check the OK (3)
▪ Start CI+ Key Download, Push the (4)
▪ Check the OK or NG
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option 5
5. Country Group
6. Area Option
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option 5
5. Country Group
6. Area Option
7
.
ADC Calibration
ඖ
8. White Balance
9. 10 Point WB
10. Test Pattern
9. 10 Point WB
10. Test Pattern
11
. EDID D/L
12. Sub B/C
13. Touch Sensitivity Setting
13. Touch Sensitivity Setting
EDID D/L
HDMI1
HDMI2
NG
HDMI3
NG
RGB
NG
NG
NG
Start
Reset
GP4_LOW
- 15 -
7.2 LAN Inspection
7.2.1. Equipment & Condition
▪ Each other connection to LAN Port of IP Hub and Jig
7.2.2. LAN inspection solution
▪ LAN Port connection with PCB
▪ Network setting at MENU Mode of TV
▪ Setting automatic IP
▪ Setting state confirmation
-> If automatic setting is finished, you confirm IP and MAC
Address.
7.3. LAN PORT INSPECTION(PING TEST)
Connect SET -> LAN port == PC -> LAN Port
7.3.1. Equipment setting
(1) Play the LAN Port Test PROGRAM.
(2) Input IP set up for an inspection to Test Program.
*IP Number : 12.12.2.2
7.3.2. LAN PORT inspection (PING TEST)
(1) Play the LAN Port Test Program.
(2) Connect each other LAN Port Jack.
(3) Play Test (F9) button and confirm OK Message.
(4) Remove LAN cable.
SET
PC
- 16 -
Et
he
rn
et
R
G
B
P
C
SP
D
IF
C
om
po
ne
nt
1
H
D
M
I1
/2
(D
VI
)
PC
/D
VI
A
ud
i I
IF
+
/-
TU
_C
VB
S
S
IF
L/
R
LG
21
11
A
IC
10
1
SE
R
IA
L
FL
A
SH
IC
14
01
(8
M
b
it)
M
X2
5L
80
05
M
2I
LV
D
S
(F
H
D
/5
0H
z)
A
ud
io
A
M
P
ST
A
38
0B
W
E
U
SB
1
DP/D
M
SP
K
L
/R
X-
ta
l
24
M
FP
C
(5
1P
)
I2
S
S
P
D
IF
C
V
BS
, Y
/P
b/
P
r,
L/
R
R
G
B
/H
/V
Rear
TM
D
S
D
D
R
3
A
dd
.
D
D
R
3
D
at
a
S
P
I
Si
de
N
A
N
D
F
LA
SH
IC
10
2
(2
G
bi
t)
P
C
M
_A
[0
:7
]
TM
D
S
H
D
M
I3
D
D
R
3
1G
b
IC
12
02
H
5T
Q
1G
63
B
FR
D
D
R
3
1G
b
IC
12
01
H
5T
Q
1G
63
B
FR
C
O
N
TR
O
L
IR &
LE
D
/
SO
FT
T
O
U
C
H
(T
A
C
T
SW
IT
C
H
)
S
E
N
S
O
R
_S
C
L/
S
D
A
LE
D
_R
K
E
Y1
K
E
Y2
IR
M
24
M
01
-H
R
M
N
6T
P
IC104
25
6K
bi
t
I2
C
TM
D
S
H
D
M
I3
Ex
ce
pt
o
f
LS
35
00
/C
S4
60
F-
SC
AR
T
S
C
1_
C
V
BS
_I
N
S
C
1_
R
/G
/B
FE
_
V
O
U
T
CI Slot
74
LC
X2
44
B
uf
fe
r
TS
_D
A
TA
[0
:7
]
P
C
M
_D
A
TA
[0
:7
]
FE
_T
S
_D
AT
A
[0
:7
]
P
C
M
_A
[8
:1
4]
Et
he
rn
et
R
G
B
PC
SP
D
IF
PC
/D
VI
A
ud
iI
L/
R
S
P
D
IF
R
G
B
/H
/V
U
SB
2
DP/D
M
E
P
H
Y
TD
SS
TD
SS
-
-
G
10
1D
G
10
1D
(L
G
IT
)
(L
G
IT
)
BLOCK DIAGRAM
Applied Model : **LS3450
Click on the first or last page to see other 42LS341C / 42LS3450 / 42LS345S / 42LS345T (CHASSIS:LD21C) service manuals if exist.