- 9 -
6. Video resolutions (3D)
6.1. HDMI Input
No.
Resolution
H-freq(kHz)
V-freq(Hz)
Pixel clock(MHz)
Proposed
3D input proposed mode
1.
1920*1080
53.95 / 54
23.98 / 24
148.35/148.5
HDTV 1080P
Frame packing
2.
1280*720
89.9 / 90
59.94/60
148.35/148.5
HDTV 720P
Frame packing
3.
1280*720
75
50
148.5
HDTV 720P
Frame packing
4
1920*1080
67.5
60
148.5
HDTV 1080P
Side by Side(half), Top and bottom
5
1920*1080
56.3
50
148.5
HDTV 1080P
Side by Side(half), Top and bottom
6
1280*720
45
60
74.25
HDTV 720P
Side by Side(half), Top and Bottom
7
1280*720
37.5
50
74.25
HDTV 720P
Side by Side(half), Top and Bottom
8
1920*1080
33.7
60
74.25
HDTV 1080i
Side by Side(half), Top and Bottom
9
1920*1080
28.125
50
74.25
HDTV 1080i
Side by Side(half), Top and Bottom
10
1920*1080
27
24
74.25
HDTV 1080P
Side by Side(half), Top and Bottom
11
1920*1080
33.7
30
89.1
HDTV 1080P
Side by Side(half), Top and Bottom
6.2. RF 3D Input(DTV)
No.
Resolution
H-freq(kHz)
V-freq.(Hz)
Pixel clock(MHz)
Proposed
3D input proposed mode
1.
1280*720
37.500
50
74.25
HDTV 720P
Side by Side, Top & Bottom
2.
1920*1080
28.125
50
74.25
HDTV 1080I
Side by Side, Top & Bottom
6.3. USB Input
6.4. DLNA Input
6.5. 3D Input mode
No.
Resolution
H-freq(kHz)
V-freq.(Hz)
Pixel clock(MHz)
Proposed
3D input proposed mode
1.
1920*1080
33.75
30.000
74.25
HDTV 1080P
Side by Side, Top & Bottom **support 
MPO(Photo)
No.
Resolution
H-freq(kHz)
V-freq.(Hz)
Pixel clock(MHz)
Proposed
3D input proposed mode
1.
1920*1080
33.75
30
74.25
HDTV 1080p
Side by Side, Top & Bottom 
No.
Side by Side
Top & Bottom
Single Frame Sequential
Frame Packing
1
- 10 -
ADJUSTMENT INSTRUCTION
1. Application Range
This  specification  sheet  is  applied  to  all  of  the  LED TV  with 
LD31B/ LD36B chassis.
2. Designation
(1)  The adjustment is according to the order which is designated 
and  which  must  be  followed,  according  to  the  plan  which 
can be changed only on agreeing.
(2) Power adjustment : Free Voltage.
(3) Magnetic Field Condition: Nil.
(4) Input signal Unit: Product Specification Standard.
(5) Reserve after operation : Above 5 Minutes (Heat Run)
  Temperature : at 25 °C ± 5 °C
  Relative humidity : 65 ± 10 %
  Input voltage : 220 V, 60 Hz
(6)  Adjustment equipments: Color Analyzer(CA-210 or CA-110), 
DDC Adjustment Jig, Service remote control.
(7) Push the "IN STOP" key - For memory initialization.
3. Main PCB check process
▪ APC - After Manual-Insert, executing APC
* Boot file Download
(1)  Execute  ISP  program  "Mstar  ISP  Utility"  and  then  click 
"Config" tab.
(2)  Set as below, and then click "Auto Detect" and check "OK" 
message.
If "Error" is displayed, check connection between computer, 
jig, and set.
(3)  Click  "Read"  tab,  and  then  load  download  file(XXXX.bin) 
by clicking "Read".
(4)  Click "Connect" tab. If "Can't" is displayed, check connection 
between computer, jig, and set.
(5) Click "Auto" tab and set as below.
(6) Click "Run".
(7) After downloading, check "OK" message.
* USB DOWNLOAD
(1) Put the USB Stick to the USB socket.
(2) Automatically detecting update file in USB Stick.
-  If your downloaded program version in USB Stick is Low, 
it didn't work. But your downloaded version is High, USB 
data is automatically detecting.
(3) Show the message "Copying files from memory".
(4) Updating is starting.
(5)  Updating Completed, The TV will restart automatically in 5 
seconds.
(6)  If  your TV  is  turned  on,  check  your  updated  version  and 
Tool option. (explain the Tool option, next stage)
*  If downloading version is more high than your TV have, TV 
can lost all channel data. In this case, you have to channel 
recover. if all channel data is cleared, you didn’t have a DTV/
ATV test on production line.
 
(1) 
 
filexxx.bin
(4) 
 
(5)
(6)
(7)...........OK
filexxx.bin
 
(2) 
 
(3) 
 
Please Check the Speed :
To use speed between
from 200KHz to 400KHz
Case1 : Software version up
1.  After downloading S/W by USB , TV set will reboot 
automatically.
2. Push “In-stop” key.
3. Push “Power on” key.
4. Function inspection
5. After function inspection, Push “In-stop” key.
Case2 : Function check at the assembly line
1.  When TV set is entering on the assembly line, Push 
“In-stop” key at first.
2. Push “Power on” key for turning it on.
→  If you push “Power on” key, TV set will recover 
channel information by itself.
3. After function inspection, Push “In-stop” key.
- 11 -
* After downloading, have to adjust Tool Option again.
(1) Push "IN-START" key in service remote control.
(2) Select "Tool Option 1" and push "OK" key.
(3) Punch in the number. (Each model has their number)
(4) Completed selecting Tool option.
3.1. ADC Process
*   If ADC  processes  as  OTP,  There  is  no  need  to  proceed 
internal ADC.
- Enter Service Mode by pushing "ADJ" key,
Calibration".
<Caution>  Using  "power  on"  key  of  the Adjustment  remote 
control, power on TV.
* ADC Calibration Protocol (RS232)
Adjust Sequence
▪ aa 00 00 [Enter Adjust Mode]
▪ xb 00 40 [Component Input480i)]
▪ ad 00 10 [Adjust 480i Comp1]
▪ aa 00 90 End Adjust mode
* Required equipment : Adjustment remote control.
3.2. EDID Download
▪ After enter Service Mode by pushing "ADJ" key.
▪ Enter EDID D/L menu.
▪ Enter "START" by pushing "OK" key.
<Caution>  Never connect HDMI && D-sub cable when EDID 
downloaded.
3.3. EDID data
(1) FHD HDMI EDID data(2D Model)
(2) Detail EDID Options are below
a. Product ID
b. Serial No: Controlled on production line.
c. Month, Year: Controlled on production line:
ex) Week : '01' -> '01'
Year : '2013' -> '17' fix
d. Model Name(Hex):
cf) TV set’s model name in EDID data is below. 
e. Checksum: Changeable by total EDID data.
f. Vendor Specific(HDMI)
3.4 Function Check
- Check display and sound 
■ Check Input and Signal items.
1) TV
2) AV (SCART / CVBS)
3) COMPONENT (480i)
4) HDMI
* Display and Sound check is executed by Remote control.
<Caution>
Not to push the INSTOP key after completion if the function 
inspection.
NO
Item
CMD 1 CMD 2 Data 0
Enter
Adjust MODE
Adjust 
‘Mode In’
A
A
0
0
When transfer the  ‘Mode In’, 
Carry the command.
ADC adjust
ADC Adjust
A
D
1
0
Automatically adjustment
(The use of a internal pattern)
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
00 00 FF FF FF FF FF FF 00 1E 6D
a
b
10
c
01 03 80 A0 5A 78 0A EE 91 A3 54 4C 99 26
20 0F 50 54 A1 08 00 31 40 45 40 61 40 71 40 81 80
30 01 01 01 01 01 01 02 3A 80 18 71 38 2D 40 58 2C
40 45 00 A0 5A 00 00 00 1E 66 21 50 B0 51 00 1B 30
50 40 70 36 00 A0 5A 00 00 00 1E 00 00 00 FD 00 3A
60 3E 1E 53 10 00 0A 20 20 20 20 20 20
d
70
d
01
e
80 02 03 22 F1 4E 10 9F 04 13 05 14 03 02 12 20 21
90 22 15 01 26 15 07 50 09 57 07
f
A0
f
01 1D 80 18 71 1C 16 20 58 2C 25 00 20 C2
B0 31 00 00 9E 01 1D 00 72 51 D0 1E 20 6E 28 55 00
C0 20 C2 31 00 00 1E 02 3A 80 18 71 38 2D 40 58 2C
D0 45 00 A0 5A 00 00 00 1E 01 1D 00 BC 52 D0 1E 20
E0 B8 28 55 40 C4 8E 21 00 00 1E 00 00 00 00 00 00
F0 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
e
MODEL NAME
HEX
EDID Table
DDC Function
HD/FHD Model
0001
01 00
Analog/Digital
Model name
MODEL NAME(HEX)
LG TV
00 00 00 FC 00 4C 47 20 54 56 0A 20 20 20 20 20 20 20 (LG TV)
EDID C/S data
FHD(8 Bit)
HDMI
Check sum
(Hex)
Block 0
42
Block 1
25 (HDMI1)
15 (HDMI2)
Input
Model name(HEX)
HDMI1
67030C001000801E
HDMI2
67030C002000801E
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Tool Option Commercial
6. Country Group
7. Area Option
8.ADC Calibration 
► 
9. White Balance
10. 10 Point WB
11. Test Pattern
12 EDID D/L
13. Sub B/C
14. Ext. Input Adjust
ADC Calibration
ADC Comp 480i
ADC Comp 1080p
ADC Type
 
 
OK
OK
OTP
Start
Reset
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Tool Option Commercial
6. Country Group
7. Area Option
8. ADC Calibration
9. White Balance
10. 10 Point WB
11. Test Pattern
12. EDID D/L 
 
13. Sub B/C
14. Ext. Input Adjust
EDID D/L
  HDMI1 
NG
  HDMI2 
NG
Start
Reset
- 12 -
4. Total Assembly line process
4.1. White Balance adjustment
▪ W/B Equipment condition
CA210 : LED -> CH14, Test signal: Inner pattern(80IRE)
▪  Above 5 minutes H/run in the inner pattern. (“power on” key 
of adjust remote control) 
▪  If it is executed W/B adjustment in 2~3 minutes H/run, it is 
adjusted by Target data.
  (For OS LED / Direct LED module)
▪ Normal line
*  Aging chamber
* Connecting picture of the measuring instrument
(On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to 
auto  controller  or  push Adjustment  R/C  POWER  ON  → 
Enter the mode of White-Balance, the pattern will come out.
* Auto-control interface and directions
(1)  Adjust in the place where the influx of light like floodlight 
around is blocked. (illumination is less than 10 lux).
(2)  Adhere closely the Color analyzer(CA210) to the module 
less than 10 cm distance, keep it with the surface of the 
Module and Color analyzer's prove vertically.(80° ~ 100°).
(3) Aging time
-  After aging start, keep the power on (no suspension of 
power supply) and heat-run over 5 minutes.
-  Using 'no signal' or 'POWER ONLY' or the others, check 
the back light on.
▪ Auto adjustment Map(using RS-232C to USB cable)
RS-232C COMMAND
[CMD  ID  DATA]
  Wb 
00  00 
White Balance Start
  Wb 
00  ff 
White Balance End
<Caution>
Color Temperature : COOL, Medium, Warm. 
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and 
adjust  other  two  lower  than  C0.(When  R/G/B  Gain  are  all 
C0, it is the FULL Dynamic Range of Module)
* Manual W/B process using adjust Remote control.
▪ After enter Service Mode by pushing "ADJ" key,
▪  Enter  White  Balance  by  pushing  "►"  key  at  "8.  White 
Balance".
* CASE Cool Mode
First  adjust  the  coordinate  far  away  from  the  target 
value(x, y).B.
1) x, y > target
2) x, y < target
3) x >target, y < target
4) x < target, y > target
   -  Every 4 case have to fit y value by adjusting B Gain 
and then fit x value by adjusting R-Gain.
   -  In  this  case,  increasing/decreasing  of  B  Gain  and  R 
Gain can be adjusted.
Mode
Temp
Coordinate spec
Target
Cool
13,000 K X=0.269 (±0.002)
Y=0.273 (±0.002)
X=0.271
Y=0.276
Medium
9,300 K
X=0.285 (±0.002)
Y=0.293 (±0.002)
X=0.287
Y=0.296
Warm
6,500 K
X=0.313 (±0.002)
Y=0.329 (±0.002)
X=0.315
Y=0.332
NetCase4 Aging time
(Min)
Cool
Medium
Warm
X
y
x
y
x
y
269
273
285
293
313
329
1
0-2
280
287
296
307
320
337
2
3-5
279
285
295
305
319
335
3
6-9
277
284
293
304
317
334
4
10-19
276
283
292
303
316
333
5
20-35
274
280
290
300
314
330
6
36-49
272
277
288
297
312
327
7
50-79
271
275
287
295
311
325
8
80-119
270
274
286
294
310
324
9
Over 120
269
273
285
293
309
323
Full White Pattern
CA-210
COLOR
ANALYZER
TYPE : CA-210
RS-232C Communication
RS-232C COMMAND
[CMD ID DATA]
MIN
CENTER
(DEFAULT)
MAX
Cool
Mid
Warm
Cool Mid Warm
R Gain jg
Ja
jd
00
172
192 192
192
G Gain jh
Jb
je
00
172
192 192
192
B Gain ji
Jc
jf
00
192
192 172
192
R Cut
64
64
64
128
G Cut
64
64
64
128
B Cut
64
64
64
128
NetCase4 Aging time
(Min)
Cool
Medium
Warm
X
y
x
y
x
y
269
273
285
293
313
329
1
0-2
276
282
292
302
316
332
2
3-5
274
280
290
300
314
330
3
6-9
273
278
289
298
313
328
4
10-19
272
276
288
296
312
326
5
20-35
271
274
287
294
311
324
6
36-49
270
272
286
292
310
322
7
50-79
266
269
282
289
306
319
 8
80-119
264
267
280
287
304
317
9
Over 120
263
266
279
286
303
316
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Tool Option Commercial
6. Country Group
7. Area Option
8. ADC Calibration
9. White Balance
10. 10 Point WB
11. Test Pattern
12 EDID D/L
13. Sub B/C
14. Ext. Input Adjust
Whit Balance
Color Temp. 
 
R-Gain
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern
Backlight
Reset 
      To Set
Cool
172
172
192
64
64
64
ON
100
Page of 76