LG 42LA6200 (CHASSIS:LT33B) Service Manual ▷ View online
- 21 -
● Manual W/B process using adjusts Remote control.(TBD)
- Color analyzer(CA100+, CA210) should be used in the
calibrated ch by CS-1000
- Operate the zero-calibration of the CA100+ or CA-210, then
stick sensor to the module when adjusting.
- After enter Service Mode by pushing “ADJ” key,
- Enter White Balance by pushing “►” key at “8. White
Balance”
● For manual adjustment, it is also possible by the following
sequence
(1) Set TV in Adj. mode using “P-ONLY” key on remote controller
and then operate heat run longer than 15 minutes.
(If not executed this step, the condition for W/B may be
different.)
(2) Push “Exit” key.
(3) Enter White Balance mode by pushing the ADJ key and select
“8. White Balance”. When KEY (►) is pressed, 206 Gray
internal pattern will be displayed.
(4) Zero Calibrate the probe of Color Analyzer, then place it on
the center of LCD module within 10cm of the surface
(5) Select each items (Red/Green/Blue Gain) using ▲/▼(CH +/-)
key on R/C..
(6) Adjust R/ G/ B Gain using ◄/►(VOL +/-) key on R/C.
(7) Adjust three modes all (Cool / Medium / Warm) -Fix the one of
R/G/B gain and change the others
(8) When adjustment is completed, exit adjustment mode using
EXIT key on R/C.
※
CASE Cool
- First adjust the coordinate far away from the target value(x, y).
(1) x, y > target
(i) Decrease the R, G.
(2) x, y < target
(i) First decrease the B gain,
(ii) Decrease the one of the others.
(3) x > target , y < target
(i) First decrease B, so make y a little more than the target.
(ii) Adjust x value by decreasing the R
(4) x < target , y > target
(i) First decrease B, so make x a little more than the target.
(ii) Adjust x value by decreasing the G
※
After You finish all adjustments, Press “In-start” button and
compare Tool option and Area option value with its BOM, if it is
correctly same then unplug the AC cable.
If it is not same, then correct it same with BOM and unplug AC
cable. For correct it to the model’s module from factory JIG
model.
※
Push The “IN STOP KEY” after completing the function
inspection.
● RS-232C Command (Commonly apply)
RS-232C COMMAND
Explanation
CMD
DATA
ID
wb
00
00
White Balance adjustment start
Wb
00
10
Start of adjust gain (Inner white pattern)
wb
00
1f
End of gain adjust
wb
00
20
Start of offset adjust(Inner white pattern)
wb
00
2f
End of offset adjust
wb
00
ff
End of White Balance adjust
(Inner pattern disappeared)
▪ “wb 00 00”: Start Auto-adjustment of white balance.
▪ “wb 00 10”: Start Gain Adjustment (Inner pattern)
▪ “jb 00 c0” :
▪ …
▪ “wb 00 1f”: End of Adjustment
* If it needs, offset adjustment (wb 00 20-start, wb 00 2f-end)
▪ “wb 00 ff”: End of white balance adjustment (inner pattern
disappear)
※
Notice) Adjustment Mapping information
RS-232C COMMAND
[CMD ID DATA]
MIN
CENTER
(DEFAULT)
MAX
Cool
Mid
Warm 00
Cool Mid
Warm
R Gain Jg
ja
jd
00
172
192
192
192
G Gain Jh
jb
je
00
172
192
192
192
B Gain Ji
jc
jf
192
192
172
192
R Gain
64
64
64
128
G Gain
64
64
64
128
B Gain
64
64
64
128
5.3. Magic Motion remote controller Check
5.3.1 Test equipment
- RF-remote controller for check, IR-KEY-CODE remote
controller.
- Check AA battery before test. A recommendation is that a
tester change battery every lots.
5.3.2. Test
(1) Make pairing with TV set by pressing “Mute (START) key”
on RCU.
(2) Check a cursor on screen by pressing ‘ENTER” or “OK”
key of RCU
(3) Stop paring with TV set by pressing “VOL+ (STOP) key.
- 22 -
5.4. 3D pattern test
5.4.1. Test equipment
(1) Pattern Generator MSHG-600 or MSPG-6100 (HDMI 1.4
support)
(2) Pattern: HDMI mode (model No. 872, pattern No. 83)
5.4.2. Test method
(1) Input 3D test signal as Fig.1.
(2) Press ‘OK” key as a 3D input OSD is shown.
(3) Check pattern as Fig2 without 3D glasses. (3D mode
without 3D glasses)
Fig.2
Fig.3
<OK in 3D mode without 3D glasses> <NG in 3D mode without 3D glasses>
5.5. HDMI ARC Function Inspection
5.5.1. Test equipment
- Optic Receiver Speaker
- MSHG-600 (SW: 1220 ↑)
- HDMI Cable (for 1.4 version)
5.5.2. Test method
(1) Insert the HDMI Cable to the HDMI ARC port from the
master equipment (HDMI1)
(2) Check the sound from the TV Set
(3) Check the Sound from the Speaker or using AV & Optic
TEST program (It’s connected to MSHG-600)
* Remark: Inspect in Power Only Mode and check SW version
in a master equipment
5.6. Selection of Country option
model (Not allowed Korean model). It is selection of Country
about Rating and Time Zone.
▪ Models: All models which use LJ22E Chassis (See the first
page.)
▪ Press “In-Start” button of Service Remocon, then enter the
“Option” Menu with “PIP CH-“ Button
▪ Select one of these three (USA, CANADA, MEXICO) defends
on its market using “Vol. +/-“button.
- 23 -
5.7. MHL Test
Step 1) Turn on TV
Step 2) Select HDMI4 mode using input Menu.
Step 3) Set MHL Zig(M1S0D3617) using MHL input, output
and power code.
Step 4) Connect HDMI cable between MHL Zig and HDMI4
port.
Step 5) Check LED light of Zig and Module of Set
Result) If, The LED light is green and The Module shows
normal stream -> OK
Else -> NG
※
Caution : Don’t push The INSTOP KEY after completing the
function inspection.
6. GND and HI-POT Testing
6.1. GND & HI-POT auto-check preparation
Check the connection between set and
power cord
(1) Check the POWER CABLE and SIGNAL CABE insertion
condition
6.2. GND & HI-POT auto-check
(1) Pallet moves in the station. (POWER CORD / AV CORD is
tightly inserted)
(2) Connect the AV JACK Tester
(3) Controller (GWS103-4) on.
(4) GND Test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, execute next process (Hi-pot test).
(Remove A/V CORD from A/V JACK BOX)
(5) HI-POT test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, GOOD Lamp on and move to next process
automatically
6.3. Check Point
(1) Test voltage
3 Poles : GND: 1.5KV/min at 100mA / SIGNAL: 3KV/min at
100mA
(2) TEST time: 1 second
(3) TEST POINT
3 Poles : GND Test = POWER CORD GND and SIGNAL
CABLE GND.
Hi-pot Test = POWER CORD GND and LIVE & NEUTRAL.
(4) LEAKAGE CURRENT: At 0.5mArms
- 24 -
7. Default Service option
7.1. ADC-Set
▪ R-Gain adjustment Value (default 128)
▪ G-Gain adjustment Value (default 128)
▪ B-Gain adjustment Value (default 128)
▪ R-Offset adjustment Value (default 128)
▪ G-Offset adjustment Value (default 128)
▪ B-Offset adjustment Value (default 128)
7.2. White balance. Value
CENTER (DEFAULT)
C50
0
W50
R Gain
192
192
192
G Gain
192
192
192
B Gain
192
192
192
R Cut
64
64
64
G Cut
64
64
64
B Cut
64
64
64
8. USB DOWNLOAD (*.epk file download)
(1) Put the USB Stick to the USB socket
(2) Press Menu key, and move OPTION
(3)
(4) Press “FAV” Press 7 times.
(5) Select download file (epk file)
(6) After download is finished, remove the USB stick.
(7) Press “IN-START” key of ADJ remote control, check the
S/W version