DOWNLOAD LG 37LV355H-TA (CHASSIS:LB0AZ) Service Manual ↓ Size: 9.81 MB | Pages: 61 in PDF or view online for FREE

Model
37LV355H-TA (CHASSIS:LB0AZ)
Pages
61
Size
9.81 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LCD
File
37lv355h-ta-chassis-lb0az.pdf
Date

LG 37LV355H-TA (CHASSIS:LB0AZ) Service Manual ▷ View online

- 8 -
7. HDMI Input
(1) DTV Mode
No.
Resolution
H-freq(kHz)
V-freq.(Hz)
Pixel clock(MHz)
Proposed
Remark
1.
720*400 31.468 
70.08 
28.321 
HDCP
2.
640*480 31.469 
59.94 
25.17
VESA  HDCP
3. 800*600
37.879
60.31 
40.00 
VESA 
HDCP
4.
1024*768
48.363
60.00 65.00 
VESA(XGA)
HDCP
5.
1360*768 47.72 59.8 84.75
WXGA  HDCP
6.
1280*1024 63.981
60.02 108.875  SXGA
HDCP/FHD 
model
7.
1920*1080 67.5 
60.00
138.5 
WUXGA
HDCP/FHD 
model
(2) PC Mode
No.
Resolution
H-freq(kHz)
V-freq.(Hz)
Pixel clock(MHz)
Proposed
Remark
1.
720*480 
31.469 /31.5 
59.94 /60
27.00/27.03
SDTV 480P
2.
720*576 31.25 
50
54 
SDTV 
576P
3.
1280*720 37.500 
50
74.25  HDTV 
720P
4.
1280*720 
44.96 /45 
59.94 /60
74.17/74.25 
HDTV 720P
5.
1920*1080 
33.72 /33.75 
59.94 /60
74.17/74.25 
HDTV 1080I
6.
1920*1080 28.125 50.00
74.25 
HDTV 
1080I
7.
1920*1080 
26.97 /27 
23.97 /24
74.17/74.25 
HDTV 1080P
8.
1920*1080
33.716 /33.75
29.976 /30.00
74.25
HDTV 1080P
9.
1920*1080 56.250 50
148.5
HDTV 
1080P
10.
1920*1080 
67.43 /67.5 
59.94 /60
148.35/148.50 
HDTV 1080P
- 9 -
ADJUSTMENT INSTRUCTION
1. Application Range
This specification sheet is applied to all of the LCD TV with
LB0AZ chassis.
2. Designation
1) The adjustment is according to the order which is designated
and which must be followed, according to the plan which can
be changed only on agreeing.
2) Power Adjustment: Free Voltage
3) Magnetic Field Condition: Nil.
4) Input signal Unit: Product Specification Standard
5) Reserve after operation: Above 5 Minutes (Heat Run)
Temperature : at 25 ºC ± 5 ºC 
Relative humidity : 65 % ± 10 %
Input voltage : 220 V, 60 Hz
6) Adjustment equipments: Color Analyzer(CA-210 or CA-110),
DDC Adjustment Jig equipment, Service remote control.
7) Push the “IN STOP” key - For memory initialization.
3. Main PCB check process
* APC - After Manual-Insert, executing APC
* Boot file Download
1) Execute ISP program “Mstar ISP Utility” and then click
“Config” tab.
2) Set as below, and then click “Auto Detect” and check “OK”
message.
If “Error” is displayed, Check connection between computer,
jig, and set.
3) Click “Read” tab, and then load download file(XXXX.bin) by
clicking “Read”.
4) Click “Connect” tab. If “Can’t” is displayed, check connection
between computer, jig, and set.
5) Click “Auto” tab and set as below.
6) Click “Run”.
7) After downloading, check “OK” message.
* USB DOWNLOAD
1) Put the USB Stick to the USB socket.
2) Automatically detecting update file in USB Stick
- If your downloaded program version in USB Stick is Low,
it didn’t work. But your downloaded version is High, USB
data is automatically detecting.
3) Show the message “Copying files from memory”.
          filexxx.bin 
(4) 
(7) 
.OK 
(5) 
(6) 
(1) 
fi lexxx.bin 
(2) 
(3) 
Please Check the Speed : 
To use speed between 
from 200KHz  to 400KHz  
Case1 : Software version up
1. After downloading S/W by USB, TV set will reboot
automatically.
2. Push “In-stop” key.
3. Push “Power on” key.
4. Function inspection
5. After function inspection, Push “In-stop” key.
Case2 : Function check at the assembly line
1. When TV set is entering on the assembly line, Push
“In-stop” key at first.
2. Push “Power on” key for turning it on.
-> If you push “Power on” key, TV set will recover
channel information by itself.
3. After function inspection, Push “In-stop” key.
4) Updating is starting.
5) Uploading completed, the TV will restart automatically.
6) If your TV is turned on, check your updated version and
Tool option.(explain the Tool option, next stage)
* If downloading version is more high than your TV have,
TV can lost all channel data. In this case, you have to
channel recover. if all channel data is cleared, you didn’t
have a DTV/ATV test on production line.
* After downloading, have to adjust Tool Option again.
1) Push “IN-START” key in service remote control.
2) Select “Tool Option 1” and Push “OK” key.
3) Punch in the number. (Each model has their number)
3.1. ADC Process
(1) ADC
G
” key at “5. ADC
Calibration”.
<Caution> Using ‘power on’ key of the Adjustment remote
control, power on TV.
* ADC Calibration Protocol (RS232)
Adjust Sequence
• aa 00 00 [Enter Adjust Mode]
• xb 00 40 [Component1 Input (480i)]
• ad 00 10 [Adjust 480i Comp1]
• xb 00 60 [RGB Input (1024*768)]
• ad 00 10 [Adjust 1024*768 RGB]
• aa 00 90 End Adjust mode
* Required equipment : Adjustment remote control.
3.2. Function Check
* Check display and sound
- Check Input and Signal items. (cf. work instructions)
1) TV
2) AV (SCART1/SCART2/ CVBS)
3) COMPONENT (480i)
4) RGB (PC : 1024 x 768 @ 60hz)
5) HDMI
6) PC Audio In
* Display and Sound check is executed by Remote control.
- 10 -
No
Item CMD1 CMD2 Data0
Enter Adjust
Adjust
A
A
0
0
When transfer the ‘Mode In’,
Mode
‘Mode In’
Carry the command.
ADC adjust ADC Adjust
D
1
0
Automatically adjustment
(The use of a internal pattern)
EZ ADJUT
0. Tool Option1  
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Country Group
5. ADC Calibration
6. White Balance
7. Test Pattern
8. EDID D/L
9. Sub B/C
10. V-Com
11. P-Gamma
ADC Calibration
ADC Comp 480i
ADC Comp 1080p
ADC RGB
NG
NG
NG
Reset
Start
4. Total Assembly line process
4.1. Adjustment Preparation
· W/B Equipment condition
CA210
: CCFL/EEFL -> CH9, Test signal: Inner pattern(80IRE)
LED -> CH14, Test signal: Inner pattern(80IRE)
· Above 5 minutes H/run in the inner pattern. (“Power on” key
of adjustment remote control)
* Connecting picture of the measuring instrument
(On Automatic control)
Inside Pattern is used when W/B is controlled. Connect to auto
controller or push Adjustment remote control POWER ON ->
Enter the mode of White-Balance, the pattern will come out.
* Auto-control interface and directions
1) Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10 lux).
2) Adhere closely the Color Analyzer (CA210) to the module
less than 10 cm distance, keep it with the surface of the
Module and Color Analyzer’s prove vertically.(80° ~ 100°)
3) Aging time
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 5 minutes.
- Using ‘no signal’ or ‘full white pattern’ or the others,
check the back light on.
• Auto adjustment Map(RS-232C)
RS-232C COMMAND
[CMD
ID DATA]
Wb
00
00
White Balance Start
Wb
00
ff
White Balance End
<Caution>
Color Temperature : COOL, Medium, Warm. 
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and
adjust other two lower than C0.
(when R/G/B Gain are all C0, it is the FULL Dynamic Range
of Module)
* Manual W/B process using adjusts Remote control.
• After enter Service Mode by pushing “ADJ” key.
• Enter White Balance by pushing “
G
” key at “6. White
Balance”.
* After done all adjustments, Press “In-start” key and
compare Tool option and Area option value with its BOM, if
it is correctly same then unplug the AC cable. If it is not
same, then correct it same with BOM and unplug AC cable.
For correct it to the model’s module from factory Jig model.
* Push the “IN STOP” key after completing the function
inspection. And Mechanical Power Switch must be set
“ON”.
4.2. DDC EDID Write (RGB 128Byte )
• Connect D-sub Signal Cable to D-sub Jack.
• Write EDID Data to EEPROM(24C02) by using DDC2B
protocol.
• Check whether written EDID data is correct or not.
* For Service main Assembly, EDID have to be downloaded to
Insert Process in advance.
4.3. DDC EDID Write (HDMI 256Byte)
• Connect HDMI Signal Cable to HDMI Jack.
• Write EDID Data to EEPROM(24C02) by using DDC2B
protocol.
• Check whether written EDID data is correct or not.
* For Service main Assembly, EDID have to be downloaded to
Insert Process in advance.
4.4. EDID DATA
1) All Data : HEXA Value
2) Changeable Data :
*: Serial No : Controlled / Data:01
**: Month : Controlled / Data:00
***: Year : Controlled
****: Check sum
- 11 -
Cool 13,000
K
X=0.269(±0.002)
Y=0.273(±0.002)
<Test Signal>
Medium
9,300
K
X=0.285(±0.002)
Inner pattern
Y=0.293(±0.002)
(204gray,80IRE)
Warm
6,500
K
X=0.313(±0.002)
Y=0.329(±0.002)
Full White Pattern
COLOR
ANALYZER
TYPE: CA-210
RS-232C Communication
CA-210
RS-232C COMMAND MIN
CENTER
MAX
[CMD ID DATA]
(DEFAULT)
Cool
Mid
Warm
Cool
Mid
Warm
R Gain
jg 
Ja 
jd 
00
172 
192 
192
192
G Gain 
jh 
Jb
je 
00
172 
192 
192
192
B Gain 
ji 
Jc 
jf
00
192 
192 
172 
192
R Cut 
64 
64 
64 
128
G Cut 
64 
64 
64 
128
B Cut 
64 
64 
64 
128
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Country Group
5. ADC Calibration
6. White Balance
7. Test Pattern
8. EDID D/L
9. Sub B/C
10. V-Com
11. P-Gamma
White Balance
Color Temp.
R-Gain
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern.
Reset
Cool
172
172
192
64
64
64
ON
To set
Page of 61
Display

Click on the first or last page to see other 37LV355H-TA (CHASSIS:LB0AZ) service manuals if exist.