LG 32LN549E / 32LP620H (CHASSIS:LB3AZ) Service Manual ▷ View online
- 11 -
* Connecting picture of the measuring instrument
(On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push Adjustment R/C P-ONLY → Enter the
mode of White-Balance, the pattern will come out.
* Auto-control interface and directions
(1) Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10 lux).
(2) Adhere closely the Color analyzer(CA210) to the module
less than 10 cm distance, keep it with the surface of the
Module and Color analyzer's prove vertically.(80° ~ 100°).
(3) Aging time
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 5 minutes.
- Using 'no signal' or 'POWER ONLY' or the others, check
the back light on.
▪ Auto adjustment Map(using RS-232C to USB cable)
RS-232C COMMAND
[CMD ID DATA]
Wb
00 00
White Balance Start
Wb
00 ff
White Balance End
<Caution>
Color Temperature : COOL, Medium, Warm.
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and
adjust other two lower than C0.(When R/G/B Gain are all
C0, it is the FULL Dynamic Range of Module)
* Manual W/B process using adjust Remote control.
▪ After enter Service Mode by pushing "ADJ" key,
▪ Enter White Balance by pushing "►" key at "7. White
Balance".
* After you finished all adjustments, Press "In-start" key and
compare Tool option and Area option value with its BOM, if
it is correctly same then unplug the AC cable. If it is not
same, then correct it same with BOM and unplug AC cable.
For correct it to the model's module from factory Jig model.
* Push the "IN STOP" key after completing the function
inspection.
4.2. DDC EDID Write (RGB 128Byte )
■ Connect D-sub Signal Cable to D-Sub Jack.
■ Write EDID DATA to EEPROM(24C02) by using DDC2B
protocol.
■ Check whether written EDID data is correct or not.
* For Service main Assembly, EDID have to be downloaded to
Insert Process in advance.
4.3. DDC EDID Write (HDMI 256Byte)
■ Connect HDMI Signal Cable to HDMI Jack.
■ Write EDID DATA to EEPROM(24C02) by using DDC2B
protocol.
■ Check whether written EDID data is correct or not.
* For Service main Assembly, EDID have to be downloaded to
Insert Process in advance.
4.4. EDID data
(1) All Data : HEXA Value
(2) Changeable Data :
*: Serial No : Controlled / Data:01
**: Month : Controlled / Data:00
***: Year : Controlled
****: Check sum
4.4.1. Auto Download
■ After enter Service Mode by pushing “ADJ” key,
■ Enter EDID D/L mode.
■ Enter “START” by pushing “OK” key.
* Caution : Never connect HDMI & D-sub Cable when EDID
downloaded.
Full White Pattern
CA-210
COLOR
ANALYZER
TYPE : CA-210
RS-232C Communication
RS-232C COMMAND
[CMD ID DATA]
MIN
CENTER
(DEFAULT)
MAX
Cool
Mid
Warm
Cool Mid Warm
R Gain jg
Ja
jd
00
172
192 192
192
G Gain jh
Jb
je
00
172
192 192
192
B Gain ji
Jc
jf
00
192
192 172
192
R Cut
64
64
64
128
G Cut
64
64
64
128
B Cut
64
64
64
128
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Tool Option Commercial
6. Country Group
7. Area Option
8. ADC Calibration
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Tool Option Commercial
6. Country Group
7. Area Option
8. ADC Calibration
9. White Balance
10. 10 Point WB
11. Test Pattern
12 EDID D/L
13. Sub B/C
14. Ext. Input Adjust
11. Test Pattern
12 EDID D/L
13. Sub B/C
14. Ext. Input Adjust
Whit Balance
Color Temp.
◄
►
R-Gain
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern
Backlight
Reset
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern
Backlight
Reset
To Set
Cool
172
192
192
192
192
64
64
64
64
64
ON
100
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Tool Option Commercial
6. Country Group
7. Area Option
8. ADC Calibration
9. White Balance
10. 10 Point WB
11. Test Pattern
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Tool Option Commercial
6. Country Group
7. Area Option
8. ADC Calibration
9. White Balance
10. 10 Point WB
11. Test Pattern
12. EDID D/L
►
13. Sub B/C
14. Ext. Input Adjust
14. Ext. Input Adjust
EDID
HDMI1
NG
HDMI2
NG
HDMI3
NG
RGB
NG
Start
Reset
EDID
HDMI1
OK
HDMI2
OK
HDMI3
OK
RGB
OK
Start
Reset
- 12 -
* EDID data and Model option download (RS232)
4.4.2. Manual Download
<Caution>
(1) Use the proper signal cable for EDID Download
- Analog EDID : Pin3 exists
- Digital EDID : Pin3 exists
(2) Never connect HDMI & D-sub Cable at the same time.
(3) Use the proper cables below for EDID Writing.
(4) Download HDMI1, HDMI2 separately because HDMI1 is
different from HDMI2.
(1) FHD RGB EDID data
(2) FHD HDMI EDID data
(3) HD RGB EDID data
(4) HD HDMI EDID data
(5) Detail EDID Options are below
a. Product ID
b. Serial No: Controlled on production line.
c. Month, Year: Controlled on production line:
ex) Week : '01' -> '01'
Year : '2012' -> '16' fix
d. Model Name(Hex):
cf) TV set’s model name in EDID data is below.
e. Checksum: Changeable by total EDID data.
NO
Item
CMD 1 CMD 2 Data 0
Enter download
MODE
Download
‘Mode In’
A
A
0
0 When transfer the ‘Mode
In’, Carry the command.
EDID data and
Model option
download
Download
A
E
00 10
Automatically download
(The use of a internal
data)
For Analog
For HDMI EDID
D-sub to D-sub
DVI-D to HDMI or HDMI to HDMI
No.
Item
Condition
Hex Data
1
Manufacturer ID
GSM
1E6D
2
Version
Digital : 1
01
3
Revision
Digital : 3
03
0
1
2
3
4
5
6
7
8
9
A B C D E
F
00 00 FF FF FF FF FF FF 00 1E 6D
a
b
10
c
01 03 68 10 09 78 0A EE 91 A3 54 4C 99 26
20 0F 50 54 A1 08 00 81 80 61 40 45 40 31 40 01 01
30 01 01 01 01 01 01 02 3A 80 18 71 38 2D 40 58 2C
40 45 00 A0 5A 00 00 00 1E 01 1D 00 72 51 D0 1E 20
50 6E 28 55 00 A0 5A 00 00 00 1E 00 00 00 FD 00 3A
60 3E 1E 53 10 00 0A 20 20 20 20 20 20
d
70
d
00 e
80 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
90 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
A0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
B0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
C0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
D0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
E0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
F0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF
0
1
2
3
4
5
6
7
8
9
A B C D E
F
00 00 FF FF FF FF FF FF 00 1E 6D
a
b
10
c
01 03 80 10 09 78 0A EE 91 A3 54 4C 99 26
20 0F 50 54 A1 08 00 71 4F 81 80 01 01 01 01 01 01
30 01 01 01 01 01 01 02 3A 80 18 71 38 2D 40 58 2C
40 45 00 A0 5A 00 00 00 1E 1B 21 50 A0 51 00 1E 30
50 48 88 35 00 A0 5A 00 00 00 1C 00 00 00 FD 00 3A
60 3E 1E 53 10 00 0A 20 20 20 20 20 20
d
70
d
01 e
80 02 03 26 F1 4E 10 1F 84 13 05 14 03 02 12 20 21
90 22 15 01 26 15 07 50 09 57 07
f
A0
f
E3 05 03 01 01 1D 80 18 71 1C 16 20 58 2C
B0 25 00 A0 5A 00 00 00 9E 01 1D 00 72 51 D0 1E 20
C0 6E 28 55 00 A0 5A 00 00 00 1E 02 3A 80 18 71 38
D0 2D 40 58 2C 45 00 A0 5A 00 00 00 1E 01 1D 00 BC
E0 52 D0 1E 20 B8 28 55 40 A0 5A 00 00 00 1E 00 00
F0 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 e
MODEL NAME
HEX
EDID Table
DDC Function
HD/FHD Model
0001
01 00
Analog/Digital
Model name
MODEL NAME(HEX)
LG TV
00 00 00 FC 00 4C 47 20 54 56 0A 20 20 20 20 20 20 20 (LG TV)
EDID C/S data
FHD
HD
HDMI
RGB
HDMI
RGB
Check sum
(Hex)
Block 0
43
5C
A4
A5
Block 1
25 (HDMI1)
-
5B (HDMI1)
15 (HDMI2)
4B (HDMI2)
5 (HDMI3)
3B (HDMI3)
- 13 -
f. Vendor Specific(HDMI)
- FHD
- HD
4.5. Outgoing condition Configuration
■ When pressing IN-STOP key by Service remote control,
Red LED are blinked alternatively. And then automatically
turn off. (Must not AC power OFF during blinking)
4.6. HI-POT Test
4.6.1. HI-POT auto-check preparation
- Check the POWER cable and SIGNAL cable insertion condition
4.6.2. HI-POT auto-check
(1) Pallet moves in the station. (POWER CORD / AV CORD is
tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) HI-POT test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, GOOD Lamp on and move to next proc-
ess automatically.
4.6.3. Checkpoint
(1) Test voltage
- Touchable Metal : 3 KV / min at 100 mA
- SIGNAL : 3 KV / min at 100 mA
(2) TEST time: 1 second. (case : mass production )
(3) TEST POINT
- Touchable Metal => LIVE & NEUTRAL : Touchable Metal.
- SIGNAL => LIVE & NEUTRAL : SIGNAL.
5. Model name & Serial number D/L
▪ Press "Power on" key of service remote control.
(Baud rate : 115200 bps)
▪ Connect RS232 Signal Cable to RS-232 Jack.
▪ Write Serial number by use RS-232.
▪ Must check the serial number at the Diagnostics of SET UP
menu. (Refer to below)
5.1. Signal Table
CMD : A0h
LENGTH : 85~94h (1~16 bytes)
ADH : EEPROM Sub Address high (00~1F)
ADL : EEPROM Sub Address low (00~FF)
Data : Write data
CS : CMD + LENGTH + ADH + ADL + Data_1 +...+ Data_n
Delay : 20ms
5.2. Comand Set
* Description
FOS Default write : <7mode data> write
Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0,
Phase
Data write : Model Name and Serial Number write in EEPROM,.
5.3. Method & notice
(1) Serial number D/L is using of scan equipment.
(2) Setting of scan equipment operated by Manufacturing
Technology Group.
(3) Serial number D/L must be conformed when it is produced
in production line, because serial number D/L is mandatory
by D-book 4.0.
* Manual Download(Model Name and Serial Number)
If the TV set is downloaded by OTA or Service man,
sometimes model name or serial number is initialized.(Not
always)
There is impossible to download by bar code scan, so It
need Manual download.
1) Press the "Instart" key of Adjustment remote control.
2) Go to the menu "5.Model Number D/L" like below photo.
3) Input the Factory model name or Serial number like
photo.
Input
Model name(HEX)
HDMI1
67030C001000B82D
HDMI2
67030C002000B82D
HDMI3
67030C003000B82D
Input
Model name(HEX)
HDMI1
65030C001000011D
HDMI2
65030C002000011D
HDMI3
65030C003000011D
CMD
LENGTH
ADH
ADL
DATA_1
. . .
Data_n
CS
DELAY
Adjust mode
CMD(hex)
LENGTH(hex)
Description
EEPROM WRITE
A0h
84h+n
n-bytes Write (n = 1~16)
- 14 -
4) Check the model name Instart menu. → Factory name
displayed. (ex 42LD450-ZA)
5) Check the Diagnostics.(DTV country only) → Buyer
model displayed.(ex 42LD450)
6. Check Commercial features
6.1. External SPK Out and Volume control
(1) Connect external speaker to speaker out port with phone
jack on TV side as below.
(2) Check the Max. speaker output is 1W or not. Sine wave
with 1KHz will be displayed.
(3) Press Vol. control button up/down in turns and check the
waveform of Oscilloscope.
6.2. IR Out and DC Power Outlet(5V/12V)
6.2.1. In using Commercial Check Jig
(1) Connect JIG for inspection to RS-232C port on TV as
below.
DC 5V Power must be supplied to JIG through AC Power
Adapter at 3.
(2) Check the LED for IR-Out inspection.
* Please refer to the criteria of Judgement.
6.2.2. In using Mini check Jig
(1) Connect JIG for inspection to RS-232C port on TV as
below.
(2) Enter the Configuration Setup mode in pressing Remote
control keys.
The method to enter Configuration Setup mode
: IN-START → MENU → Configuration Setup → OK
1) Select 5V DC Power Outlet and change the setting : No
→ Yes. After that, check LED color in JIG.
2) After checking 5V DC Power Outlet, change the setting :
Yes → No.
3) Please check 12V DC Power Outlet in the same
procedure.
(3) Check the LED for IR-Out inspection.
* Please refer to the criteria of Judgement.
Vol. control for External SPK
External SPK
Button of Vol. control
Waveform of Oscilloscope
UP(+)
DOWN(-)
Recommended Input Signal
: RF, 1kHz, Sine wave
Click on the first or last page to see other 32LN549E / 32LP620H (CHASSIS:LB3AZ) service manuals if exist.